Standart analizler için

Filter

 Secchi Disk

WinLab

For determining the depth of visibility and light permeability of water. Sturdy design made of strong, hard-wearing plastic. Lead weight for better lowering. The approx. 15 cm high rod is fitted with an eyelet for fastening the lowering engine. The lowering line is marked in intervals of 100 cm with figures from 1 to 10 and in between additionally with line markings each 50 cm for better reading of the depth of visibility while the disk is being lowered....

 Accessories for B.O.D. Auto-Check Measurement Systems OxiTop®

WTW

...

 behrotest ® column elution unit for the elution of soil samples

Behr

Column elution unit:
Column elution unit in acc. with the LUA recommendation with 4-channel hose pump with controllable speed. The unit consists of :

  • Assembly stand for the system
  • Controllable 4-channel hose pump with fixed speed
  • Storage vessel, 20 l
  • 4 elution columns, internal diameter 6 cm, 32 cm long, with 2 screwed joints (GL 45, with PTFE inserts) for simple filling of the columns
  • 4 collection bottles for the column eluate, 2 l, with screwed joint (GL 45) and deaeration
  • Supply tube made of TYGON and PVC, with non-return valve in the supply to the column
  • PTFE tubes between columns and collection vessels
  • Flow rate 0.003 to 35 ml/min
  • Range of speed 2 to 100 min-1
  • Simultaneous control of all 4 channels
...

 behrotest® compact equipment for elution of solid matters

Behr

Percolation equipment to jointly examine the elution behaviour of inorganic and organic substances in solid matters. Including hose pump with 2 channels and 2 different pump tubes for a flow rate of 0.25-12 ml/min. and 0.66-33 ml/min. (Other pump tubes upon request).
Complete equipment, consisting of...

 behrotest® flow-through unit, Aquabox

Behr

The Aquabox flow-through unit enables the correct, expert determination of on-site parameters during the collection of soil and sewage samples. The unit permits the simultaneous determination of electrolytic and physico-chemical parameters under optimal and reproducible flow conditions.

Aquabox is constructed of transparent, shock-resistant PETG, a thermoplastic copolyester. The transparent construction allows constant visual identification of problems during operation, e.g. sand or sediment contamination. All components which come into contact with water are made of non-wetting PETG (flow chamber and lid) or PP (inlet and outlet tubing). Therefore the water being sampled is not affected by any release of contaminants from the materials used for construction of the Aquabox. The lid is splashproof and easy to open and close by means of a quick-release fastener. The lid has 6 variable diameter, splashproof sensor holders for inserting sensors up to 25mm diameter (larger diameters available on request)....

 behrotest® waste water mixers

Behr

behrotest ® homogenisers. With transportable sample vessels. Homogenisers for pre-treatment, splitting and homogenization of heterogeneous water samples in accordance with the quality assurance and quality control standards for wastewater examinations. The vessels of the homogenizers are protected against damage in the yolk type frame and can be carried easily by the two handles. They can be filled at the sampling location by a flattened inlet connection. Capacities from 2 to 25 l permit extraction and collection of multiple samples. Exact measurement of the sample quantities due to graduation. Subsequently, the transport rack is just placed on the magnetic stirrer in the laboratory or in the sampling vehicle and the homogeniser is immediately ready for use. The speed of the magnetic stirrer can be adjusted by a controller. The user can thus comply with the specified cone height in all cases. Oxygen is thus prevented from entering the samples. Dosed extraction of the homogenised sample via PTFE spindle stopcock. 12V, with adapter for mains connection....

 Compact system for determination of volatile oils KOL

Behr

Complete and compact system for volatile oil determination according to DAB, with base unit, heating mantle, mounting frame and glassware....

 Continuous steam generator behrotest® WE 1/H

Behr

The injection of steam into the sample
guarantees a particularly gentle and uniform distillation. Steam is produced almost immediately (within maximum of 30seconds). The maximum period of steam injection depends only on the size of the external
container.
In WE 1 the distillation occurs only as a result of water vapour...

 Cryoscope standards

Reagecon

Compatible for use on all Cryoscopes compliant to International Reference Standard ISO5764/IDF108 for the determination of Freezing Point in milk. High accuracy, 1 year shelf-life (from Date of Manufacturing). Supplied in 250 and 100ml HDPE bottle and a convenient cap with collapsible filling nozzle...

 CUS 2 clean-up-station

Behr

The behrotest ® clean-up column with glass frit corresponds exactly to the provisions of ISO 9377-2.
The practical twin stand provides safe support for two complete clean-up units with dropping funnel, clean-up columns and Kuderna-Danish flasks. Thus, the complete clean-up procedure can be carried out for two samples simultaneously - without delays due to time-consuming equipment or sample manipulation....

 Equipment to determine anaerobic digestion

Behr

The complete equipment consists of:

  • Tempering bath with thermostat for 6 eudiometer units incl. clamping device for eudiometer tubes
  • 6 eudiometer units with laboratory bottles, 500ml, eudiometer tubes with graduation, stopcock and connecting tube and levelling bulb
  • Series magnetic stirrer, for use in water bath to stir 6 bottles, each with 500 ml, including separate control unit
...

 Extraction unit EX 1000

Behr

Determination of hydrocarbon EX 1000 extraction unit
The PFL sampling bottle is ideal for direct extraction in terms of ISO 9377-2. With its solid glass stopper, in addition it offers a decisive advantage in handling and safety.

The funnel separator facilitates the separation of the organic phase. The individual functional parts of the separator can be easily separated. The user can thus transfer the organic phase quickly and simply in one step to the clean-up column. In addition the individual functional parts are particularly easy to clean....

 KOSTA 2 nitrogen station

Behr

The two-stage concentration of the organic phase is concluded by reducing the extract down to less than 1 ml under a mild nitrogen flow.
In the behrotest ® nitrogen station, a distributor leads the nitrogen flow via two individually adjustable tubes into the Kuderna-Danish flasks. Thus, two samples can be reduced simultaneously in accordance with ISO 9377-2....

 Laboratory purification plants to determine the biodegradability, according to DIN 38412

Behr

e.g. for the Coupled Units Test in acc. with OECD 303 A, complete.
optional:

  • Dentrification step with pump and stirrers
  • Oxygen control, consisting of:
Oxygen measuring unit for preliminary sedimentation with a voltage output for switching the air supply on and off behrotest...

 ORION™ conductivity and TDS standards

Thermo

For calibration of conductivity and TDS testers.

  • All standards are NIST™ traceable
  • When using the automatic calibration function on ORION™ software, the programmed temperature tables can be used
...

 Accessories for cyanide distillation

Behr

...

 Absorption Vessel

Behr

...

 Extractors for Soxhlet extraction

Behr

Extractors with specially developed siphon tubes guarantee uniform extraction cycles. Extractors with stopcock (type H) eliminate the additional distillation after extraction....

 96 Well Immuno™ Modules

Thermo

Developed for quantitative and qualitative solid phase immuno assays, e.g. ELISA techniques.

  • Alphanumeric orientation systems
  • Standard format 128 x 86 mm
  • High optical quality
  • Four choices for bottom: flat bottom (F), round b. (U), flat with curved b. (C) or StarWell™
  • Frames and modules available separately
  • Modules remain in frame when inverted
  • Certified reproducibility of binding
  • Free-standing modul
...

 Moisture Analyser HX/HS series

Mettler-Toledo

Professional moisture analysers with fast halogen drying technology, made for sophisticated tasks. Very high accuracy and reproducibility. Integrated user management with password protection. 7 inch colour touchscreen with intuitive user guidance. Drying curves and "Good-Bad-ratings", based on individually configurable control limits, are displayed in realtime. 5 automatic and individually definable switch-off criteria. Connectivity with Wi-Fi, LAN, RS232 or USB interface to PCs, FTP servers and printers....

 Sample Concentrators SC-200

Carl Stuart Limited

A sample concentrator is a fast and convenient way of concentrating multiple samples in a block heater at once. Utilising a simple gas delivery system the sample concentrator passes an inert gas over the surface of the samples via stainless steel needles. This in combination with the heat from the block heater below produces ideal conditions for fast, efficient evaporation....

 TC-Temperature probes for testo measuring devices, TC plug type T

Testo

Temperature probes with TC plug type T....

 Sucrose (Brix) Standards

Reagecon

Certified stabilized Sucrose (Brix) Standards.

  • ISO 17025 accredited
  • Uncertainty of measurement of 0.11 % for all Brix values at 20 °C
  • Equivalent Nominal Refractive Index values from ICUMSA published tables reported on Certificate of Analysis
  • Compatible with any brand of Refractometer
  • 12 month shelf life
  • Provided in high quality HDPE 15 ml dropper bottles
...

 Test strips Chem-QUANT®

CHEMLAB

  • Reliable and precise
  • Non-bleeding
  • Easy and quick analysis
  • Made in Europe
...

behr extraction thimbles for extractor EZ30(H)

Behr

PO number Package size Price per package    

1

9843807

This product of our assortment corresponds with your search.

25 piece Login / Register here
shopping_cart
savings

Add to shopping cart