SPE

Filter

 CHROMABOND® Na2SO4/Florisil®

MACHEREY-NAGEL

Combination phase for SPE of hydrocarbons from water acc. to DIN H53 / ISO DIS 9377-4

Special combination phase of sodium sulphate and Florisil ®.

Recommended application: hydrocarbons from drinking, surface and waste waters....

 Accessories for CHROMABOND®

MACHEREY-NAGEL

...

 CHROMABOND® C18 ec

MACHEREY-NAGEL

Octadecyl modified silica phase for SPE, endcapped

Base material silica, pore size 60 Å, particle size 45 µm for C 18 ec, 100 µm for C 18 ec f (for fast flow), specific surface 500 m²/g, pH stability 2 to 8. Octadecyl phases, endcapped, carbon content 14 % very non-polar, hydrophobic interactions with a wide variety of organic compounds. Advantageous for clean-up of samples with large structural variations (polarity differences)....

 CHROMABOND® vacuum manifolds and accessories

MACHEREY-NAGEL

For simultaneous preparation of up to 12 or 24 samples,
replacement parts and accessories for special applications
.

Vacuum manifold complete consists of: glass cabinet with lid and lid gasket, removable needles on lower side of lid, vacuum gauge, control valve, valves and caps, variable rack....

 CHROMABOND® NH2/C18

MACHEREY-NAGEL

Combination phase for SPE analysis of PAH from water containing humic acids

Special combination phase: aminopropyl phase for removal of interfering humic acids, octadecyl phase for enrichment of PAH.

Recommended application: PAH from water containing humic acids....

 CHROMABOND® QuEChERS extraction buffer mixes / clean-up mixes

MACHEREY-NAGEL

QuEChERS method and pre-mixes
Within a few years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strong matrix-contaminated samples.
Standard clean-up of food samples...

 CHROMABOND® SiOH

MACHEREY-NAGEL

Unmodified silica phase for SPE

Unmodified, weakly acidic silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, very polar, adsorbs humidity from air, for this reason it should be kept well closed and if necessary dried before use due to its high affinity for polar compounds it should not be conditioned with polar (e.g. methanol) or water-containing solvents....

 CHROMABOND® NH2

MACHEREY-NAGEL

Aminopropyl modified silica phase for SPE

Base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, aminopropyl phase, carbon content 3.5%, polar, weak anion exchanger.

Recommended applications: trace elements, lipids....

 CHROMABOND® C18

MACHEREY-NAGEL

Octadecyl modified silica phase for SPE, not endcapped

Base material silica, pore size 60 Å, particle size 45 µm for C 18, specific surface 500 m²/g, pH stability 2 to 8 octadecyl phases, not endcapped, carbon content 14 % possesses more free silanols (SiOH), which allow secondary interactions with polar groups of the analytes....

 CHROMABOND® Drug II

MACHEREY-NAGEL

Special silica phase for SPE of THC and derivatives acidic analytes from biological fluids (urine, blood ...)

base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, special bifunctional modification - C 8/ SB (strong anion exchanger - quaternary amine)....

 CHROMABOND® XTR

MACHEREY-NAGEL

Kieselguhr phase for liquid-liquid extraction

Base material coarse-grained kieselguhr, large pore size, high pore volume, constantly high batch-to-batch quality, pH working range 1 to 13.

Application: liquid-liquid extraction of highly viscous aqueous solutions such as physiological fluids (blood, plasma, and serum) in clinical chemistry, dyes in textiles, environmental and food analysis....

 CHROMABOND® Easy

MACHEREY-NAGEL

Polar modified polystyrene-divinylbenzene copolymer with a weak anion exchanger

Specific surface 650 to 700 m²/g, particle size 80µm, pore size 50 Å, pH stability 1 to 14. Due to bifunctional modification much more hydrophilic than conventional polystyrene-divinylbenzene polymers and thus easily wettable with water....

 CHROMABOND® Florisil®

MACHEREY-NAGEL

Magnesium silicate for SPE

Matrix magnesium silicate (MgO to SiOH 15:85), high purity, particle size 150 to 250µm.

Recommended application: organic tin compounds, aliphatic carboxylic acids, PCB, PAH....

 CHROMABOND® HR-X

MACHEREY-NAGEL

Spherical, hydrophobic polystyrene-divinylbenzene resin for SPE
Hydrophobic polystyrene-divinylbenzene copolymer pH stability 1 to14. High-purity material with highest reproducibility and lowest blank values due to a novel manufacturing process, spherical particles 85mm; pore size 55 to 60Å. Very high surface 1000m²/g; capacity 390mg/g (caffeine in water). Excellent recovery rates especially for the enrichment of pharmaceuticals/active ingredients due to the spherical structure of the particles, very homogeneous surface, and optimised pore structure....

 CHROMABOND® SiOH-H2SO4/SA

MACHEREY-NAGEL
GHS05

Combination phase for SPE analysis of PCBs

H2SO4: H 2SO 4-impregnated silica phase for oxidation of accompanying compounds to ionic and/or polar compounds.
SA: strongly acidic cation exchanger based on silica with benzenesulphonic acid modification for removal of ionic and sulphur-containing compounds....

 Reservoir columns for application of medium-size samples

MACHEREY-NAGEL

...

 QuEChERS adsorbent CHROMABOND® Diamino / PSA

MACHEREY-NAGEL

QuEChERS method and pre-mixes
Within a few years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strong matrix-contaminated samples.
Standard clean-up of food samples...

 CHROMABOND® XTR Sorbens

MACHEREY-NAGEL

50 bags of 14.5g (for max. 20ml aqueous solution each)....

 Empty columns CHROMABOND®, PP

MACHEREY-NAGEL

Empty CHROMABOND ® column (PP) for SPE, one PE-filter element is already inserted in the column....

 CHROMAFIL® MULTI 96 filter plates

MACHEREY-NAGEL

96-well polypropylene plates for simultaneous filtration of 96 samples
Advantages of this high-throughput system are:

  • economical by saving time and solvent
  • use of multi-channel pipettors facilitates liquid transfer steps
  • readily adaptable to all common automated/robotic handling systems
  • minimised dead volume (≤ 40µl)
  • membrane materials correspond to the respective CHROMAFIL® syringe filters
...

 Adapters for CHROMABOND® columns

MACHEREY-NAGEL

...

 Accessories CHROMABOND® QuEchERS

MACHEREY-NAGEL

QuEChERS method and pre-mixes
Within a few years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strong matrix-contaminated samples.
Standard clean-up of food samples...

 CHROMABOND® CN/SiOH

MACHEREY-NAGEL

Combination phase for SPE analysis of PAH

Special combination phase, cyanopropyl phase for selective adsorption of polycyclic aromatics via Π-Π interactions, unmodified silica phase for removal of polar compounds.

Recommended applications: Extraction of the 16 PAHs according to EPA from soil samples....

 CHROMABOND® Drug

MACHEREY-NAGEL

Special silica phase for SPE enrichment of drugs from urine or plasma

Base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, special bifunctional modification - C 8/SA (strong cation exchanger - benzenesulphonic acid).

...

 CHROMABOND® NAN

MACHEREY-NAGEL
GHS05

Special phase for SPE analysis of PCB from sludge

Special combination phase:
N: sodium sulphate for removal of trace water.
A: SiOH/AgNO 3 phase for removal of sulphur, sulphur-containing and polar compounds.

Recommended application: extraction of PCB from sludge....

Add to shopping cart