Photometric analyses (cuvette tests)

Filter

 Deuterium lamp for spectrophotometer LLG-uniSPEC

LLG

...

 Reagent Tablets for Photometers and Comparators Lovibond®

Tintometer

...

 Reagent tablets for Photometer Lovibond®

Tintometer

...

 Reagent solutions for photometers Lovibond®

Tintometer

Solution with 15 ml or refill bottle with 100 ml....

 Reagents VARIO for Photometer Lovibond®and HACH®

Tintometer
GHS03 GHS05 GHS07 GHS08 Restricted raw material

Suitable for Lovibond ®Photometers as well as for Photometers of company HACH ®*...

 Photometer photoLab® and photoFlex®, stored test protocols

WTW
GHS05 GHS07

A: Stored in photoLab ® S6, S12, photoLab ® 6000 Serie and photoLab ® Spektral
B: Stored in photoLab ® S12, photoLab ® 6000 Serie and photoLab ® Spektral
C: Stored in photoFlex ® and photoFlex ® Turb ®...

 Reagent tablets for Comparators CHECKIT® / 2000+

Tintometer

...

 Photometer photoLab® and photoFlex®, stored test programs

WTW
GHS05 GHS09 Restricted raw material

A: Stored in photoLab ® S6, S12, photoLab ® 6000/7000 Serie and photoLab ® Spectral
B: Stored in photoLab ® S12, photoLab ® 6000/7000 Serie and photoLab ® Spectral
C: Stored in photoFlex ® STD, photoFlex ®...

 Reference standard kits Chloride for photometers MD series

Tintometer

The reference standards are used to check the photometric detection accuracy and reproducibility of measurement results. Adjustment of the photometers is not possible with the reference standard kits. When checking the photometers with the reference standard kit, the appropriate method is selected and the measured value in mg/L is compared with the reference value of the standard kit. The shelf life is two years from the date of manufacture if used and stored properly....

 Cuvettes for photometers

Tintometer

...

 Accessories for Photometers PrimeLab 1.0

LLG

...

 Cells for Photometer photoLab®

WTW

Cuvettes for photometric routine and water analytics in the UV-VIS and VIS range. Cells with matt side surface are suitable for the automatic cell detection of the photoLab ® filter and spectral photometer. The glass and quartz cuvettes have a marking in order to place the cuvettes into the photometer in the same direction for an even higher precision....

 Accessories for photometer photoFlex® series and turbidimeters Turb® 430 series

WTW

LabStation with LSdata software for easy data evaluation. The rechargeable battery is included in the delivery.

  • direct export to MS-Excel
  • GLP-conform data transfer
  • calibration curve calculation
  • adjustment between meter and PC
...

 Accessories to Flame Photometer FF-200

Jenway

Please Note: These products will only operate with the correct type of air compressor and gas regulator as specified below....

 Thermoreactor RD 125

Tintometer

Chemical digestion of samples is required for the photometric determination of COD, TOC, total chromium, total phosphate and total nitrogen. The required temperatures and reaction time can be selected by using the membrane keypad of the reactor RD 125. The unit works at three different temperatures (100 / 120 / 150 °C) and three pre-set reaction times (30 / 60 / 120 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm. The RD 125 reactor is fitted with 24 holes for 16 mm diameter vials....

 Handheld photometers pHotoFlex® series, with / without pH and turbidity measurement

WTW

Handheld photometers for use in a wide range of areas such as process control, mobile water testing or wine industry. Easy operation with menu driven, user guidance.

  • Smart cuvette adapter: holds 28mm or 16mm round cuvettes with height 91 to 104mm; to be used with a variety of different test types
  • Optics: LED's with filters, accuracy < 2nm
  • Available wavelengths: 436 nm, 517 nm, 557 nm, 594 nm, 610 nm and 690 nm
  • Concentration, Absorption, Transmission
  • Methods can be downloaded from the Internet
  • 35 (pHotoFlex® STD) 100 user defined routines
  • 100 (pHotoFlex® STD) / 1000 data sets, RS 232 interface
  • pH range: pH 0 to 16.00 (±0.01) for DIN standard combination electrodes
  • incl. calibration interval and calibration protocol
  • Batteries: 4 button cells
...

 Photometer photoLab® and photoFlex®, stored test programs

WTW
GHS05 GHS06 GHS08 Restricted raw material

A: Stored in photoLab ® S6, S12, photoLab ® 6000/7000 Series and photoLab ® Spectral
B: Stored in photoLab ® S12, photoLab ® 6000/7000 Series and photoLab ® Spectral
C: Stored in photoFlex ® STD, photoFlex ®...

 Photometer photoLab® S6 and S12 - Filter photometer

WTW

High-precision, laboratory photometers with multilevel AQA / IQC functions. Features easy operation, GLP-conforming documentation, simultaneous turbidity compensation: open cover, place cell, measure! Automatic selftest and zeroing of the optical systems during start up. AutoSelect for cuvettes recognition via barcode; all necessary settings automatically of more than 150 programmed methods with automatic cuvette detection. Unique barcode-support for 10, 20 und 50 mm cuvette for high quality and economic reagent test kits. The RS232 interface transfers data to the user"s PC. With real time clock and memory (incl. date/time) for 500 (S6) or 1000 (S12) data records. To be used with 16mm round cells and rectangular cells (only S12) 10, 20 and 50mm path length. Autozeroing. CE, UL, CUL tested....

 Accessories for Lovibond® photometers

Tintometer

...

 Photometer system MD 600 / MD 610

Tintometer

Modern, mobile photometers for rapid, reliable water testing
All important water analysis parameters from Aluminium to Zinc are covered by these two devices. Combined with the high precision of Lovibond ® reagents, a reliable and quick analysis of water samples is guaranteed. Reagent tablets, powder reagents, liquid reagents, or cuvette tests are used depending on the method. Please order separately. Six long-lasting LEDs serving as a light source in combination with interference filters guarantee the highest precision. The devices are designed without moving optical parts and thus have a maintenance-free measuring unit. Up to 1000 data records can be stored in the MD 600, MD 610 stores 500 data records....

 Photometer system MultiDirect

Tintometer

With Dual Beam Technology. The MultiDirect is a modern, microprocessor-controlled photometer with ergonomically designed keypad and large-format graphic display. It is equipped with a wide range of pre-programmed methods (e.g. ammonia, COD, phosphate) based on the proven range of Lovibond ®...

 Reference standard kit pH for photometers MD series

Tintometer
GHS02 GHS07

The reference standards are used to check the photometric detection accuracy and reproducibility of measurement results. Adjustment of the photometers is not possible with the reference standard kits. When checking the photometers with the reference standard kit, the appropriate method is selected and the measured value in mg/L is compared with the reference value of the standard kit. The shelf life is two years from the date of manufacture if used and stored properly....

 Photometers MD 100

Lovibond

The Lovibond ® MD 100 Photometers are designed for analysis of different parameters in drinking water, industrial process water and waste water. With a total of more than 30 different types, instruments are available for routine testing as well as for special applications. The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Provided with calibration and software-based adjustment options the MD 100 is suitable for use as a testing instrument. The tests are conducted using either Lovibond...

 Reagents for Photometer MD 100 Boiler Water/Cooling Water

Tintometer

...

 Photometers MD 100 Boiler Water/Cooling Water

Tintometer

Photometer instruments, specially designed for cooling and boiler water analysis. Thanks to the handy format and the user-friendly indicator chemistry, most of the important parameters can be determined on site. The photometers are supplied pre-calibrated with test methods, simply add the appropriate Lovibond...

Add to shopping cart