-
- General laboratory consumables
- Occupational safety, Security
- Analytical measurement and testing
- Stirring, Shaking, Mixing
- Sample preparation
- Distillation, separation, filtration
- Heating and cooling technology
- Liquid Handling
- Vacuum technology, Drying, Dry storage
- Optical instruments and microscopes
- Cleaning and sterilisation
- Environmental-, soil-, water-, food analysis
- Chromatography
- Cleanroom
Glass working
Guard columns for EC columns NUCLEODUR® C18 Isis, 3µm
C18 phase with special polymeric, crosslinked surface modification - USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%C
high steric selectivity
outstanding surface deactivation
suitable for
LC/MS due low bleeding characteristics
pH stability 1 - 10
broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins...
Accessories and replacement parts for EC columns
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart...
Guard columns for EC columns NUCLEODUR® C18 Gravity, 3µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases
available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...
VarioPrep columns for preparative HPLC C18 Pyramid, 5µm
stabel in 100 % aqueous eluent systems- USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 % C
7 and 10µm particles for preparative separations on request
interesting polar selectivity features
excellent base deactivation; suitable for
LC/MS due low bleeding characteristics...
VarioPrep columns for preparative HPLC NUCLEODUR® C18 Isis, 5µm
C18 phase with special polymeric, crosslinked surface modification - USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%C
high steric selectivity
outstanding surface deactivation
suitable for
LC/MS due low bleeding characteristics
pH stability 1 - 10
broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins...
VarioPrep columns for preparative HPLC NUCLEODUR® Sphinx RP, 5µm
distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for
LC/MS...
VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....
VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5, 100-7, 100-10, C18 ec
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....
VarioPrep preparative columns NUCLEDUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....
VarioPrep preparative columns NUCLEODUR® 100-10 C18 ec, 10µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....
VarioPrep preparative columns NUCLEODUR® 100-5 C18ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....
VarioPrep preparative columns NUCLEODUR® 100-5 SioH ( unmodified ), 5µm
totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0,9ml/g, surface (BET) 340m²/g, density 0.47g/ml, pressure stability 800 bar, pH stability 2 - 8; available particle sizes 3µm and 5µm; larger particles (10, 12, 16, 20 , 30 and 50µm) for preparative applications are available as bulk materials....
VarioPrep preparative columns NUCLEODUR® C18 Gravity
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases
available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...
VarioPrep preparative columns NUCLEODUR® C18 Isis
C18 phase with special polymeric, crosslinked surface modification - USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%C
high steric selectivity
outstanding surface deactivation
suitable for
LC/MS due low bleeding characteristics
pH stability 1 - 10
broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins...
VarioPrep preparative columns NUCLEODUR® C18 Pyramid
stabel in 100 % aqueous eluent systems- USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 % C
7 and 10µm particles for preparative separations on request
interesting polar selectivity features
excellent base deactivation; suitable for
LC/MS due low bleeding characteristics...
VarioPrep preparative columns NUCLEODUR® Sphinx RP
distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for
LC/MS...
Capillary columns GC BP20
Polyethylene Glycol phase. GC column for analyses such as alcohol, free acids, fatty acid methyl esters, aromatics, solvents and essential oils. Suitable replacement for: Carbowax 20M, CP-Wax 52 CB, DB-WAX, Elite-WAX, HP-20M, HP-INNOWax RH-WAX, Rtx-Wax, Stabilwax, SUPELCOWAX 10, TG-WaxMS, VF-WAXms, ZB-WAX....
Capillary columns GC BPX5
5% Phenyl Polysilphenylene-siloxane. General purpose GC column for routine gas chromatographic analysis. Suitable replacement for: DB-5, DB-5ms, DB-5.625, XTI-5, Rtx-5ms, Ultra-2, HP-5, HP-5MS, HP5-TA, SPB-5, MDN-5S, CP-Sil8CB, Rxt-Sil 5MS, AT-5ms, VB-5, ZB-5, VF-5ms.
- Very low bleed
- Non-polar
- Extremely inert
Guard columns for NUCLEOGEL® SUGAR 810 Ca columns
sulphonated polystyrene / divinylbenzene resins in diffent ionic forms
and RP chromatography
separation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatography
H
+ form: separation of sugars, sugar alcohols and organic acids - USP L17 - eluent in column 0.01 N H2SO4...
Guard columns for NUCLEOGEL® SUGAR 810 H columns
sulphonated polystyrene / divinylbenzene resins in diffent ionic forms
and RP chromatography
separation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatography
H
+ form: separation of sugars, sugar alcohols and organic acids - USP L17 - eluent in column 0.01 N H2SO4...
EC analytical columns NUCLEODUR® C18 Isis, 1.8µm
C18 phase with special polymeric, crosslinked surface modification - USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%C
high steric selectivity
outstanding surface deactivation
suitable for
LC/MS due low bleeding characteristics
pH stability 1 - 10
broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins...
EC analytical columns NUCLEODUR® 100-3 C18 ec, 3 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....