-
- General laboratory consumables
- Occupational safety, Security
- Analytical measurement and testing
- Stirring, Shaking, Mixing
- Sample preparation
- Distillation, separation, filtration
- Heating and cooling technology
- Liquid Handling
- Vacuum technology, Drying, Dry storage
- Optical instruments and microscopes
- Cleaning and sterilisation
- Environmental-, soil-, water-, food analysis
- Chromatography
- Cleanroom
Counting chambers
Counting chamber, Improved Neubauer

Bright line. With double ruling. Calibratable. Same counting grid as the Improved Neubauer cell, but with rhodium coated chamber base. Rulings are engraved into the Rhodium layer and appear bright under normal microscope settings. By altering the contrast it is possible to reverse the image under the microscope to make the rulings appear brighter or darker as required....
Counting chambers, Fuchs-Rosenthal ruling, bright line

Bright lined, double net ruling, includes 2 haemocytometer glass covers, with LOT number on the packaging, labelled with: usable until, CE pursuant to IVD 98/79 EC. Grid has 16 x large 1 mm² squares. Each square is divided into 16 smaller squares each with a side length of 0.25 mm and an area of 0.0625 mm². These counting chambers are commonly used to count cells in cerebrospinal fluid....
Counting chambers C-Chip, four chambers

Disposable counting chamber made of optical plastic. Dimensions: 25 x 75 mm, thickness 1,6 mm. Various applications such as blood cell counting, cell concentration measurement, sperm counting, investigation of cell viability and bacteria and fungal spore counting.
- No need for coverslips
- Reduces the risk of infectious materials
- Quartz grade optical plastic
- Guaranteed repeatability and reliability
- Individually wrapped
Counting chambers, Thoma ruling, bright line

Bright lined, double net ruling, includes 2 haemocytometer glass covers, with LOT number on the packaging, labelled with: usable until, CE pursuant to IVD 98/79 EC. Grid is the same as the grid in the centre of large square in the Neubauer chamber. The area of the small square is 0.0025 mm². Since the large outer squares are not included, the Thoma system is only used to count thrombocytes and erythrocytes....
Counting chamber according to Improved Neubauer (Petroff)
Counting chamber with special depths (Petroff), Tolerance ±1 µm. For analysis of cell suspensions.
- With double ruling
- In compliance with DIN ISO 12 847
- With 2 haemacytometer cover glasses 20 x 26 x 0.4 mm
- Counting grids are engraved into two ground and polished surfaces in the chamber bottom, located between two elevated also ground and polished stages.
- Individually packed
Counting chamber according to Thoma
For analysis of cell suspensions.
- With double ruling
- In compliance with DIN ISO 12 847
- Tolerance of depth of chamber max. 2 %
- Counting grids are engraved into two ground and polished surfaces in the chamber bottom, located between two elevated also ground and polished stages.
- With 2 haemacytometer cover glasses 20 x 26 x 0.4 mm
- Individually packed
Counting Chambers according to Bürker

For counting thrombocytes or erythrocytes.
For export outside EU only, chamber depth 0.1 mm.
Ruling:
- 9 large squares, surface area 1 mm² each = 9 mm²
- Each large square is divided into 16 groups of squares 0.2 x 0.2 mm
- Additionally there are small squares of a surface area of 0.0025 mm² each
Counting chambers, Nageotte ruling, bright line
Bright lined, double net ruling, includes 2 haemocytometer glass covers, with LOT number on the packaging, labelled with: usable until, CE pursuant to IVD 98/79 EC. For cell counting with very low cell values, e.g. liquor cerebrospinalis, counting residual leucocytes in erythrocyte and thrombocyte PLT concentrates or in plasma. Also suitable for counting of nematodes. The bands are countd by meandering succession....