-
- General laboratory consumables
- Occupational safety, Security
- Analytical measurement and testing
- Stirring, Shaking, Mixing
- Sample preparation
- Distillation, separation, filtration
- Heating and cooling technology
- Liquid Handling
- Vacuum technology, Drying, Dry storage
- Optical instruments and microscopes
- Cleaning and sterilisation
- Environmental-, soil-, water-, food analysis
- Chromatography
- Cleanroom
HPLC columns
EC analytical columns NUCLEODUR® C18Pyramid, 5µm
stabel in 100 % aqueous eluent systems- USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 % C
7 and 10µm particles for preparative separations on request
interesting polar selectivity features
excellent base deactivation; suitable for
LC/MS due low bleeding characteristics...
EC analytical columns NUCLEODUR® C8Gravity, 5µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases
available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...
EC analytical columns NUCLEODUR® C18 Gravity, 5µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases
available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...
EC analytical columns NUCLEODUR® Sphinx RP, 3µm
distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for
LC/MS...
EC analytical columns NUCLEODUR® Sphinx RP, 5µm
distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for
LC/MS...
EC analytical columns NUCLEODUR® 100-3 CN-RP, 3µm
pore size 110 Å, particle sizes 3µm and 5µm; 7%C - USP L10
multi-mode columns (RP and NP)
widens the scope in selectivity
differnet retention characteristics compared to C8 and C18
stable against hydrolysis at low pH values, working range pH 1-8
high reproducibility from lot to lot...
EC analytical columns NUCLEODUR® 100-5 CN, 5µm
pore size 110 Å, particle sizes 3µm and 5µm; 7%C - USP L10
multi-mode columns (RP and NP)
widens the scope in selectivity
differnet retention characteristics compared to C8 and C18
stable against hydrolysis at low pH values, working range pH 1-8
high reproducibility from lot to lot...
EC analytical columns NUCLEODUR® 100-5 CN-RP, 5µm
pore size 110 Å, particle sizes 3µm and 5µm; 7%C - USP L10
multi-mode columns (RP and NP)
widens the scope in selectivity
differnet retention characteristics compared to C8 and C18
stable against hydrolysis at low pH values, working range pH 1-8
high reproducibility from lot to lot...
EC analytical columns NUCLEODUR® 100-5 NH2, 5µm
pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8
multi-mode columns (RP and NP)
normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides
reversed phase chromatography (RP) ...
EC analytical columns NUCLEODUR® 100-5 NH2-RP, 5µm
pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8
multi-mode columns (RP and NP)
normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides
reversed phase chromatography (RP) ...