- General laboratory consumables
- Occupational safety, Security
- Analytical measurement and testing
- Stirring, Shaking, Mixing
- Sample preparation
- Distillation, separation, filtration
- Heating and cooling technology
- Liquid Handling
- Vacuum technology, Drying, Dry storage
- Optical instruments and microscopes
- Cleaning and sterilisation
- Environmental-, soil-, water-, food analysis
- Chromatography
- Cleanroom
Membrane filters
Syringe filter Minisart® NML, SFAC
Housing MBS. SFCA / CA (Surfactant-free Cellulose Acetate) membrane. For sterile, particle free, ultrapure filtration of small volumes of liquid up to approx. 100 ml. Colour coded and printed for easy membrane and pore size identification. With hydrophilic cellulose acetate membrane for minimum adsorption. Ready-to-use. With female luer-lock inlet, male luer slip outlet....
Syringeless filters SEPARA
SEPARA integrates in one single device auto-sampler vial, filtration membrane, plunger, and cap/septa. The single step filtering process is efficient and saves time. Fast and simple to use. Reducing sample loss. After filtration the sample is ready to use in most standard autosampler. The pre-slit cap ensures easy and clean transfer of sample. 5 different septa material, PP vial with Ø 12 x 33 mm, Filtering capacity 0.48 ml, dead volume <30 µl, maximum operating temperature 50 °C...
MF-Millipore™ membrane, mixed cellulose ester, 47 mm
MF-Millipore™ Membranes have a biologically inert mixture of cellulose acetate and cellulose nitrate. The MF-Millipore™ filters without Triton® surfactant have a lower water extractable content compared to the standard MF-Millipore™ filters and contain a minimal amount of wetting agent.
Features & Benefits:...
Steritop™ Filter units
For fast and uncomplicated sterile filtration of aqueous solutions in bottles with narrow or wide threads, the Steritop™ bottle top filter with large filter surface is ideal. Inside the funnel there is a small tab with which you can securely attach a separately available pre-filter during filtration. In order to provide optimum protection against contamination, the thread of the bottle cap is slightly set back....
Durapore® Membrane Filter
Durapore® PVDF membranes are characterized by high throughput and high flow rate. To maximize recovery and minimize interaction with your sample, the membrane has very low protein binding.
Features & Benefits:
- Can be sterilized by ethylene oxide and gamma irradiation
- Available in different pore sizes
Membrane Filters, nylon
Recommended for filtration, sterilisation and clarifications of mobile phase in HPLC processes with aqueous, alkaline and organic samples
- Made entirely of polyamide, hydrophilic
- High non-specific adsorption, high mechanical stability
- Qualified for many solvents and alkaline solutions, pH range 3-14
- Maximum temperature 134 °C
Millipak® Filter
The stacked-disk format of Millipak® filter units eliminates the risk of fiber release from downstream support material.
Features & Benefits:
- No risk of membrane cracking as the 0.22 µm membrane is supported by a rigid plastic disc with channels
- As the membranes are welded onto the support disc, the risk of contamination is considerably reduced
- Minimum dead volume thanks to the large filter surface
MF-Millipore™ membrane, mixed cellulose ester, 25 mm
MF-Millipore™ Membranes have a biologically inert mixture of cellulose acetate and cellulose nitrate. The MF-Millipore™ filters without Triton® surfactant have a lower water extractable content compared to the standard MF-Millipore™ filters and contain a minimal amount of wetting agent.
Features & Benefits:...
MF-Millipore™ membrane, mixed cellulose ester, black
MF-Millipore™ Membranes have a biologically inert mixture of cellulose acetate and cellulose nitrate. The MF-Millipore™ filters without Triton® surfactant have a lower water extractable content compared to the standard MF-Millipore™ filters and contain a minimal amount of wetting agent.
Features & Benefits:...
Microcon®
Solutions of any macromolecules, simple and efficient, desalt and concentrate. Suitable for any centrifuge holding 1.5 ml tubes.
Features & Benefits:
- Even with diluted solutions the recovery is more than 95%.
- Reverse spin to maximize recovery even in the smallest sample
- Storage of filtrate or concentrated sample, very easy in standard microcentrifuge tubes
- concentration factor up to 100 x
Membrane Filters, Cyclopore™, PC
Membrane filters Cyclopore™ polycarbonate are true pore size microporous membranes featuring the sharp cut-off and reproducible microfiltration characteristics of track-etched membrane filters.
- Low affinity for stains improves visibility under a microscope
- Low protein binding minimizes sample loss of proteinaceous samples
- Narrow pore size distribution and high pore density support rapid surface capture of analyte
- Negligible absorption and adsorption of filtrate; nonhygroscopic
- No particle shedding enables clean filtrate
- Biologically inert
- Filters are autoclavable for 30 min at 121 °C
Disposable Filtration Capsules, Polycap TF™
Hydrophobic PTFE membrane for applications involving organic solvents and chemically aggressive solutions.
- Maximum operating pressure of 4.1 bar forward and 3.0 bar reverse
- 1 µm capsules incorporate a PP prefilter
- Autoclavable up to 132 °C maximum
- Connectors: stepped barb (SB) and female national pipe thread (FNPT)
Durapore® Membrane Filters, hydrophobic PVDF
Durapore® PVDF membranes offer high flow rates and throughput, low extraction, agents, and broad chemical compatibility.
Features & Benefits:
- Can be sterilized by ethylene oxide and gamma irridation
- Avialable in different pore size
- Very low protein binding to minimize interaction with your sample and maximize recovery
Filtration Capsules Polycap TC
Polycap TC filtration capsules feature dual layer polyethersulfone (PES) membranes and provide efficient filtration for aqueous solutions.
- 100% integrity-tested during manufacturing
- Polypropylene housing thermally fused to eliminate surfactants and mold releasing agents that could affect analysis
- Manufactured according to ISO9001:2008 QMS standards
- Available in sterile versions with a filling bell option
- PES membranes protein adsorption characteristics: HAS 0.4 µg/cm²; Insulin 2.0 µg/cm²; gammaglobulin 1.5 µg/cm²
- Connectors: stepped barb (SB)
Immobilon NC-Membranes
In contrast to nitrocellulose, Immobilon membranes have a number of advantages. An optimized coloring capacity, a broad solvent compatibility and a lower background make the membranes your solution. Immobilon membranes do not rupture or curl and can be cut without breaking. Reprobing is also possible many times. The Immobilon NC membrane without surfactant, is perfect for not disturbing cell wall integrity during cell wall growth....
Membrane filters, mixed cellulose ester, with grid
Recommended for clarification and sterilisation of aqueous solutions, microbiological analysis and particle counts
- Membranes with grid lines are ideal for microbiological analysis (bacterial counts) of water, pharmaceuticals, beverages, cosmetics, etc. for the measurement of coliform bacteria and other germs
- Gridded membranes (black grid on white membrane) for counts of colonies as a standard method of quantification, black grid, clearly defined sections (3.1 x 3.1 mm grid)
- Special ink, non-toxic and totally free from bacterial growth inhibitors, is used for imprinting
- Sterilised membranes (packaged in individual blisters)
Membrane Filter, mixed cellulose ester
Recommended for clarification and sterilisation of aqueous solutions, microbiological analysis and particle counts.
- Qualified for aqueous solutions (pH 4-8), hydrocarbons and some dilute solvents
- High non-specific adsorption: 160 µg/cm2 for gamma globulin and pore size 0.2 µm (decreases with increasing pore size)
- High mechanical stability, ideal for gravimetrical measurements
- Maximum temperature 180 °C
Membrane Filters, cellulose acetate, non sterile
Recommended for aqueous samples, biological applications and protein filtration.
- Compatible to aqueous solutions with pH 4-8, most alcohols, hydrocarbons and oils
- Filtration of aqueous solutions for biological and clinical analysis
- Sterilisation of biological solutions (CA-membranes with a pore size of 0.2 µm are specially recommended when the recovery of proteins is critical)
- High thermal stability: 180 °C
- Very low nonspecific adsorption
Membrane Filter, hydrophobic, PTFE
Made entirely of PTFE (polytetrafluorethylene), reinforced by Polypropylene net.
- Permanently hydrophobic
- Allowing passage of air even at low differential pressure
- Resistant to almost all chemicals, very strong acids, cryoliquids, alkalis, aggressive organic solvents
- Must be pre-wetted with an organic solvent, such as ethanol, methanol or isopropanol, before filtration of aqueous samples
- Max. Temperature 145 °C