Hygromètres
Membrane de transfert LLG, en nitrocellulose renforcée

Les membranes de transfert en nitrocellulose renforcée combinent la capacité de liaison des membranes en nitrocellulose à la force de résistance de celles en nylon. Ces membranes sont utilisées pour les transferts d'ADN/ARN nécessitant un faible bruit de fond ou pour les hybridations multiples. Elles sont bien adaptées pour la chimiluminescence ou les systèmes de détection radiographiques. Capacité de liaison BSA jusqu'à 100 µg/cm...
Membrane de transfert LLG, nitrocellulose renforcée 0,45µm, 200mm x 20cm, VE=5
LLG
PO number | Package size | Price per package | |||
---|---|---|---|---|---|
6268174 This product of our assortment corresponds with your search. |
5 Pièce | Login / Register here |
|
Membrane de transfert LLG, en nitrocellulose renforcée, Largeur mm: 200, Longueur mm: 200, Taille des pores µm: 0.22
LLG
PO number | Package size | Price per package | |||
---|---|---|---|---|---|
6268175 This product of our assortment corresponds with your search. |
5 Pièce | Login / Register here |
|
Membrane de transfert LLG, nitrocellulose, Largeur mm: 200, Longueur mm: 200, Taille des pores µm: 0.22
LLG
PO number | Package size | Price per package | |||
---|---|---|---|---|---|
6268163 This product of our assortment corresponds with your search. |
25 Pièce | Login / Register here |
|
Amersham™ Protran™ 0.45 NC nitrocellulose Western blotting membranes
Nitrocellulose membranes with a 0.45 µm pore size for use in Western blot protocols. Excellent sensitivity, resolution, and low background. for a wide range of laboratory applications.
Features & Benefits:
- Low background and excellent signal-to-noise ratios
- Compatible with a variety of labelling and detection systems
- High binding capacity
- Suitable for proteins with a wide range of molecular weights
- Ideal tool for your antibody purification and analysis workflow
- Long shelf life of bound proteins
Amersham™ Hyperfilm ECL™

Double-coated, high sensitivity film optimized for use in all blue and green light chemiluminescence systems for Western blot analysis and validated for use with Amersham ECL™ and CDP-Star.
Features & Benefits:
- High sensitivity Western blot membrane to detect low concentrations of nucleic acid and protein targets
- Clear background for excellent contrast and improved band resolution
- Produces publication-quality images
- Easy to read and simple-to-use
- To be processed in automatic processors or manually in tanks and trays using most common X-ray film developers and fixers
Amersham™ Hybond™ P 0.45 PVDF blotting membranes
PVDF blotting membrane with 0.45 µm pore size, hydrophobic and of high physical strength, for use with standard colorimetric and chemiluminescent detection methods for proteins of < Mr 20 000.
Features & Benefits:
- Protein binding capacity over 200 μg/cm² for easy signal detection.
- High protein retention even after harsh washing steps.
- High protein capture during transfer minimizes sample loss.
- Suitable for stripping and reprobing
Transfer membranes Amersham Hybond LFP, PVDF
Low fluorescent, hydrophobic blotting membrane for protein transfer. Optimized for fluorescence detection in Western blotting applications.
- Protein binding capacity over 200 µg/cm2
- Higher sensitivity due to low background fluorescence
- Compatible with many blocking agents, transfer buffers and total protein blot stains
- Available in the standard precut sizes for laboratory applications
Amersham™ Hybond™ P 0.2 PVDF Western blotting membranes

PVDF blotting membrane with 0.2 µm pore size, hydrophobic with high physical strength, for use with standard colorimetric and chemiluminescent detection methods. The small pore size of the membrane minimizes "blow-through" and increases protein binding over a wide range of molecular weights.
...
Amersham™ Protran™ 0.2 NC nitrocellulose Western blotting membranes
Nitrocellulose membranes with a 0.2 µm pore size, offering excellent sensitivity, resolution and low background for Western blot protocols.
Features & Benefits:
- Low background and excellent signal-to-noise ratios, without the need for stringent washing conditions
- Compatible with a variety of Western blot labeling and detection systems
- Risk of ”blow-through“ reduced by high binding capacity of small proteins (< Mr 20 000)
- Optimized for chemiluminescent and fluorescent detection
- Long shelf life of bound proteins to the transfer membrane
Amersham™ Protran™ Premium 0.2 NC nitrocellulose Western blotting membranes
Nitrocellulose blotting membrane, with 0.2 µm pore size, for excellent sensitivity, resolution, and low background.
Features & Benefits:
- Low auto-fluorescence across a wide range of excitation/emission wavelengths makes the membrane suitable for fluorescence-based immunodetection and multiplexing.
- High binding capacity (173 - 203 µg IgG/cm²) of small proteins (< Mr 20 000) reduces risk of "blow-through"
Amersham™ Protran™ Premium 0.45 NC nitrocellulose Western blotting membranes
Nitrocellulose blotting membrane with 0.45 µm pore size, for excellent sensitivity, resolution and low background.
Features & Benefits:
- High binding capacity (162 - 180 µg IgG/cm²)
- Suitable for proteins of a wide range of molecular weights
- 100% pure nitrocellulose membrane for use with all ECL Western blotting systems and protein blotting applications.
- Available in popular precut sizes for laboratory application
Amersham™ Protran™ 0.45 NC supported Western blotting membranes
Reinforced 0.45 µm protein blotting membrane for multiple reprobings.
Features & Benefits:
- High binding capacity
- Versatile, robust and excellent signal-to-noise ratios
- Optimal for applications when stripping and reprobing is required
- Suitable for proteins of a wide range of molecular weights
Blotters semi-secs

Ces blotters semi-secs permettent un transfert rapide d'ADN, d'ARN et de protéines en láespace de 15 à 30 minutes seulement. Adapté à tous types de blotting : western, southern et northern grâce à un tampon et procédures adaptées. Compatibles avec des épaisseurs de gels de 0,25 à 10 mm sans besoin d'équipement supplémentaire. Chaque unité est compatible avec son système omniPAGE vertical correspondant. Le botting semi-sec a pour avantage le transferts économiques car une utilisation très faible de volume de tampon. Typiquement, uniquement quelques millilitres de tampons sont nécessaires par transfert. Opération sûre et temps de transfert homogène grâce au couvercle à vis hermétique (permettant un contrˆle parfait de la pression). Les électrodes, anode revêtue de Pt et cathode en acier inox, ne se corrodent pas et permettent une utilisation sûre pendant plusieurs années. La dispersion uniforme de la chaleur permet un temps de transfert stable sans perte d'échantillon due à la chaleur ni distortion de transfert. Translucide, permet une vision du blot, pour s'assurer du positionnement et du transfert corrects. Les plaques d'électrodes sont complètement séparées pour éviter toute déformation ou endommagement....
Papiers de blotting

Recommandés pour les méthodes de blotting avec des gels comme Southern, Northern et Western Blots, ainsi que les blottings semi-secs de protéines
- Fabriqués à partir de matériaux ultra-purs sans utilisation d'additifs, il n'y a donc pas de risque de contamination des membranes et des gels pendant les étapes de transfert
- Effet capillaire uniforme et transfert régulier des liquides
- Résistance élevée à l'humidité pour une manipulation en sécurité
Système de transfert Nytran SuPerCharge TURBOBLOTTER™

Le TurboBlotter est un système de transfert très facile à installer, simple et peu coûteux, qui travaille sans courant électrique ou source de vide. Permet une haute résolution de transfert d'ADN et ARN en juste une heure.
Dispositif de blotting économisant du tampon et du papier de blotting.
...
Blotter humide omniBLOT

L'omniBlot est une unité autonome pour le procédé de blot en cuve. Chaque unité est constituée d'une cuve OmniPAGE et d'un couvercle, d'un insert d'électroblotting ainsi que de cassettes et de tampons de fibres. Le design universel de la cuve et des couvercles correspondants est compatible avec les systèmes PAGE verticaux ou IEF avec les inserts correspondants en option....
Immobilon FL-Membrane
In contrast to nitrocellulose, Immobilon membranes have a number of advantages. An optimized coloring capacity, a broad solvent compatibility and a lower background make the membranes your solution. Immobilon membranes do not rupture or curl and can be cut without breaking. Reprobing is also possible many times. The Immobilon FL membranes are ideal for fluorescence applications thanks to their optimized transfer membrane....
Membrane de transfert, en nitrocellulose renforcée

Les membranes de transfert en nitrocellulose renforcée combinent la capacité de liaison des membranes en nitrocellulose à la force de résistance de celles en nylon. Ces membranes sont utilisées pour les transferts d'ADN/ARN nécessitant un faible bruit de fond ou pour les hybridations multiples. Elles sont bien adaptées pour la chimiluminescence ou les systèmes de détection radiographiques. Capacité de liaison BSA jusqu'à 100 µg/cm...
Membrane de transfert, nitrocellulose

Membrane de transfert en nitrocellulose pure pour toutes les applications en protéine ou immunoblotting. Sensibilité élevée et faible bruit de fond garantissent des résultats exceptionnels dans tous les transferts. Compatible avec tous les systèmes de détection. Capacité de liaison BSA jusqu'à 100 µg/cm...