Blot Imaging

Filter

 Amersham™ ECL™ Prime Western Blotting Detection Reagent

Cytiva

Highly sensitive chemiluminescence detection reagent with long-lasting signal for accurate detection of minute changes in protein levels. Stable signal emission, enabling repeated exposures and making it easier to process several blots in the same experimental run.

Features & Benefits:

  • Intense and long-lasting signal allows for multiple exposures, making the reagent highly suitable for large experimental series and allowing for convenient handling time between the end of the experiment and detection
  • Accurate detection of both high and low abundant proteins on the same blot after a single exposure
  • Optimized for use with Amersham Hybond P (PVDF) membranes and compatible with Amersham Protran (nitrocellulose) Western blotting membranes
  • Compatible with Amersham ECL Rainbow Molecular Weight Markers and Amersham ECL DualVue Western Blotting Markers
...

 Filters for Gel documentation systems chemiPRO

Cleaver

...

 Amersham™ ECL™ rainbow molecular weight markers

Cytiva

Ready-to-load marker providing sharper, more intense bands on gels and blots and improved band spacing for more accurate molecular weight determination. The bright, distinctive colors of the markers allow easier confirmation of transfer to blotting membranes and orientation.
Comprising a mixture of individually colored proteins that are combined to produce bands of equal color intensity. The approximate protein concentration is 1 to 2 mg/ml, depending on the product. Each 250 µl pack size is sufficient for use with 50 minigels (10 x 8 cm) or 25 large gels (20 x 20 cm)....

 Sistema de documentación de gel chemiPRO-302E

Cleaver

Solución completa para quimioluminiscencia y Western blot fluorescente. Con cámara CCD refrigerada de alta sensibilidad y alta eficiencia cuántica, para la detección de proteínas de nivel picogramo. La refrigeración Peltier permite aumentar los tiempos de exposición para detectar la quimioluminiscencia débil sin añadir ruidos de fondo molestos. Adecuado para manchas occidentales de quimioluminiscencia, auto-radios, ADN o ARN teñidos con bromuro de etidio, SYPRO, SYBR y tintes SAFE en geles de agarosa, proteínas teñidas de azul Coomassie o plata en geles de acrilamida, geles libres de manchas, geles fluorescentes o manchas teñidas con Qdots, DyLight, Alexa Fluor, CY DYES y tintes IR LI-COR. Además GFP-plantimaging, detección de colonias o placas en placas de Agar, bioluminiscencia y geles 2d. El software gratuito permite la creación automática de imágenes de manchas multicolores con una interfaz sencilla y fácil de usar....

 HI-LED lighting modules for Gel documentation systems chemiPRO

Cleaver

...

 Gel documentation system chemiPRO XL6 / XL9

Cleaver

Imaging system for the detection of proteins in Western Blot analysis. Peltier cooling of the highly sensitive CCD camera allows exposure times to be increased to detect even faint chemiluminescence without adding background noise.

  • Cooled, high-resolution camera with high quantum efficiency (QE)
  • Motorised lens, stage and filter wheel (7-stage)
  • Long-life white LED EPI lighting
  • CFR21 Part 11 compliant
  • With acquisition and analysis software genePIX and geneQUANT
...

 Amersham™ ECL™ Select Western Blotting Detection Reagent

Cytiva

Very sensitive chemiluminescent detection reagent with highly intense signal output, for detection of medium to very low protein levels. High signal intensity makes ECL Select suitable for demanding Western blotting applications, allowing detection of minute protein quantities. Its long lasting signals allows for multiple exposures and a convenient time window between the experiment and analysis. Signals can be detected with a CCD camera or X-ray film....

 Immobilon HRP Substrat

Millipore

The Immobilon Western HRP substrate offers a high sensitivity for Western or dot/slot/spot blotting on PVDF membranes as well as on nitrocellulose membranes. The HRP substrate is compatible with all commonly used buffers and blocking reagents. Blots on PVDF membranes can be re-examined, allowing detection of multiple target proteins on the same blot....

 Kits de sustrato, ECL

Cleaver

Sustrato de ECL con salida lumínica estable. La formulación proporciona un fondo bajo para una alta relación señal-ruido.
El kit de prueba incluye soluciones de luminol / potenciador y peróxido.

LumiGO: Para la detección de picogramas bajos. 125 ml de solución de luminol/enriquecedor, 125 ml de solución de peróxido....

 Mini Western Blotting Workflow Package WESTERNFLOWPROMINI

Cleaver

Complete package for Western blotting of mini gels with chemiluminescence. It includes everything necessary from gel loading to gel documentation and quantification.

  • Gel documentation system chemiPro with UV transilluminator and large imaging area. Acquisition and analysis software is already included licence-free
  • Vertical electrophoresis tank omniPAGE Mini for protein analysis in up to 4 gels
  • Power supply PowerPro can be operated in constant mode or programmed. With the power supply can be used to operate both the electrophoresis tank and the semi-dry blotter
...

Add to shopping cart