Cells W600
Cells made of optical glass or Borosilicate glass 3.3, 21 mm x 40 mm, for instument Models Fs, PFXi/PFX195, 880, 950 and 995. (Note: PFXi/PFX-195 max. path length 50 mm).
W600/OG/xx for unheated samples (up to 40 °C)
W600/B/xx for heated samples (up to max. 100 °C)
Further versions available on request....
BOD-Measurement-System BD 600
BOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days....
pH meter SensoDirect pH 110
The SensoDirect pH 110 is a portable, battery operated pH meter. The instrument is equipped as standard with protective casing and built-in electrode holder. It is equipped with a LC display showing two decimal places. The gel electrode of the SensoDirect pH 110 is temperature resistant over the range -5 to 80 °C. It is fitted with a BNC connector as standard....
Reference standard kits Chloride for photometers MD series
The reference standards are used to check the photometric detection accuracy and reproducibility of measurement results. Adjustment of the photometers is not possible with the reference standard kits. When checking the photometers with the reference standard kit, the appropriate method is selected and the measured value in mg/L is compared with the reference value of the standard kit. The shelf life is two years from the date of manufacture if used and stored properly....
Thermostatic cabinets TC, with steel door
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display....