HPLC columns

Filter

 EC analytical columns NUCLEODUR® C18 Isis, 5
µ
m

MACHEREY-NAGEL

C18 phase with special polymeric, crosslinked surface modification - USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%C
high steric selectivity
outstanding surface deactivation
suitable for LC/MS due low bleeding characteristics
pH stability 1 - 10
broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins...

 EC analytical columns NUCLEODUR® 100-3 C8 ec, 3
µ
m

MACHEREY-NAGEL

Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....

 EC analytical columns NUCLEODUR® 100-5 C8 ec, 5
µ
m

MACHEREY-NAGEL

Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....

 EC analytical columns NUCLEODUR® C18 Gravity, 3
µ
m

MACHEREY-NAGEL

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases

available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...

 EC analytical columns NUCLEODUR® C18 Pyramid, 3
µ
m

MACHEREY-NAGEL

stabel in 100 % aqueous eluent systems- USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 % C
7 and 10µm particles for preparative separations on request
interesting polar selectivity features
excellent base deactivation; suitable for LC/MS due low bleeding characteristics...

 EC analytical columns NUCLEODUR® C18Pyramid, 5
µ
m

MACHEREY-NAGEL

stabel in 100 % aqueous eluent systems- USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 % C
7 and 10µm particles for preparative separations on request
interesting polar selectivity features
excellent base deactivation; suitable for LC/MS due low bleeding characteristics...

 EC analytical columns NUCLEODUR® C8Gravity, 5
µ
m

MACHEREY-NAGEL

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases

available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...

 EC analytical columns NUCLEODUR® C18 Gravity, 5
µ
m

MACHEREY-NAGEL

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases

available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...

 EC analytical columns NUCLEODUR® Sphinx RP, 3
µ
m

MACHEREY-NAGEL

distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for LC/MS...

 EC analytical columns NUCLEODUR® Sphinx RP, 5
µ
m

MACHEREY-NAGEL

distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for LC/MS...

 EC analytical columns NUCLEODUR® 100-3 CN-RP, 3
µ
m

MACHEREY-NAGEL

pore size 110 Å, particle sizes 3µm and 5µm; 7%C - USP L10
multi-mode columns (RP and NP)
widens the scope in selectivity
differnet retention characteristics compared to C8 and C18
stable against hydrolysis at low pH values, working range pH 1-8
high reproducibility from lot to lot...

 EC analytical columns NUCLEODUR® 100-5 CN, 5
µ
m

MACHEREY-NAGEL

pore size 110 Å, particle sizes 3µm and 5µm; 7%C - USP L10
multi-mode columns (RP and NP)
widens the scope in selectivity
differnet retention characteristics compared to C8 and C18
stable against hydrolysis at low pH values, working range pH 1-8
high reproducibility from lot to lot...

 EC analytical columns NUCLEODUR® 100-5 CN-RP, 5
µ
m

MACHEREY-NAGEL

pore size 110 Å, particle sizes 3µm and 5µm; 7%C - USP L10
multi-mode columns (RP and NP)
widens the scope in selectivity
differnet retention characteristics compared to C8 and C18
stable against hydrolysis at low pH values, working range pH 1-8
high reproducibility from lot to lot...

 EC analytical columns NUCLEODUR® 100-5 NH2, 5
µ
m

MACHEREY-NAGEL

pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8
multi-mode columns (RP and NP)
normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides
reversed phase chromatography (RP) ...

 EC analytical columns NUCLEODUR® 100-5 NH2-RP, 5
µ
m

MACHEREY-NAGEL

pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8
multi-mode columns (RP and NP)
normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides
reversed phase chromatography (RP) ...

 EC analytical columns NUCLEOSIL® 100-5 C18 PAH, 5
µ
m

MACHEREY-NAGEL

Base material NUCLEOSIL ® silica, particle size 5µm, pore size 110 Å; polymeric coating - USP L1; eluent in column acetonitrile / water 70:30; allows efficient gradient separation of the 16 PAH in accordance with EPA, detection of the separated PAH by UV (250 to 280nm), with diode array or with fluorescence detection at different wavelegths for excitation and emission (acenaphthylene cannot be analysed with fluorescence detection)....

 EC analytical columns NUCLEOCEL DELTA-RP S, 5
µ
m

MACHEREY-NAGEL

NUCLEOCEL DELTA enantiomer separation based on cellulose derivatives

base material silica,
chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40
similar phases: Chiralcel ® OD, Kromasil ®, CelluCoat™, Eurocel ® 01
standard particle size 10µm...

 EC analytical columns NUCLEOCEL DELTA S, 5
µ
m

MACHEREY-NAGEL

NUCLEOCEL DELTA enantiomer separation based on cellulose derivatives

base material silica,
chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40
similar phases: Chiralcel ® OD, Kromasil ®, CelluCoat™, Eurocel ® 01
standard particle size 10µm...

 EC analytical columns NUCLEODUR® 100-3

MACHEREY-NAGEL

totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0,9ml/g, surface (BET) 340m²/g, density 0.47g/ml, pressure stability 800 bar, pH stability 2 - 8; available particle sizes 3µm and 5µm; larger particles (10, 12, 16, 20 , 30 and 50µm) for preparative applications are available as bulk materials....

 EC analytical columns NUCLEODUR® 100-3 NH2-RP, 3
µ
m

MACHEREY-NAGEL

pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8
multi-mode columns (RP and NP)
normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides
reversed phase chromatography (RP) ...

 EC analytical columns NUCLEODUR® 100-5

MACHEREY-NAGEL

totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0,9ml/g, surface (BET) 340m²/g, density 0.47g/ml, pressure stability 800 bar, pH stability 2 - 8; available particle sizes 3µm and 5µm; larger particles (10, 12, 16, 20 , 30 and 50µm) for preparative applications are available as bulk materials....

 EC analytical columns NUCLEODUR® C18 Gravity, 1.8
µ
m

MACHEREY-NAGEL

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases

available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...

 EC analytical columns NUCLEODUR® C18 Pyramid, 1.8
µ
m

MACHEREY-NAGEL

stabel in 100 % aqueous eluent systems- USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 % C
7 and 10µm particles for preparative separations on request
interesting polar selectivity features
excellent base deactivation; suitable for LC/MS due low bleeding characteristics...

 EC analytical columns NUCLEODUR® C8Gravity, 1.8
µ
m

MACHEREY-NAGEL

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases

available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...

 EC analytical columns NUCLEODUR® Sphinx RP, 1.8
µ
m

MACHEREY-NAGEL

distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for LC/MS...

Add to shopping cart