Solvent storage/handling

Filter

 Reagent bottles DURAN®, pressure resistant

DWK

DURAN ® reagent bottles, DIN thread, ISO 4796. Pressure resistance, as a result of amended shape, in the range of -1 up to +1.5 bar (tested by the TÜV in accordance with DIN EN 1595, with GS mark). Neutral / Type 1 glass in accordance with USP/EP. With Retrace code (Batch identification). Certificate available via the Internet. Autoclavable....

 Flexible connecting system for DURAN® GL 45 flasks

DWK

For safe transfer of liquid media within a closed and sterile system (evaporation is reduced).

  • Screw closure GL 45 with two, three or four ports GL 14 thread
  • Autoclavable
  • Temperature restistant up to max. 140 °C
  • Flexible modular system
  • Sterile pressure equalisation is possible through use of a membrane filter
  • Unused ports can be provided with a blind cap
...

 Safety Waste Caps V2.0, GL 45

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.
Scope of supply:
...

 SafetyWasteCaps, V2.0, S 60/61

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.
Scope of supply:
...

 Blindstopfen für SafetyCaps / SafetyWasteCaps

SCAT

...

 HPLC bottles, DURAN® complete system 4-port screw cap

DWK

For sterile transfer of media or for feeding solvent to HPLC instruments. The bottle is pressure/vacuum resistant from -1 to +1.5 bar (tested by TÜV in accordance with EN 1596, GS marked). Complete with a 4-port screw cap (autoclavable, reusable) made from PP, 4 connection screw caps (black, M8 thread) and silicone seal. Suitable for tube diameters of 1.6mm and 3.2mm. Spare parts are available individually. Further connection system components for the GL45 thread are available upon request (Tubing not included). Neutral / Type I glass acc. to USP/EP. With Retrace Code (Batch Identification), with certificate available via the internet. Autoclavable....

 Tube fittings for the tube connector Safety Waste Caps

SCAT

Connectors for variable tube connector sizes on Safety Waste Caps.
Further configurations available on request....

 HPLC starter kits Generation 2.0, GL 45

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.

  • Complete set for one HPLC system with up to 4 solvent reservoirs
  • Price advantage compared to ordering piece by piece
  • Suitable for all current HPLC systems
  • Use the supplied blind plugs to tighten connectors which are temporarily inactive or not in use
...

 Collectors for tube connector for SafetyWasteCaps

SCAT

Collectors for additional parts to add more tubings and capillaries. Delivered with fittings.
Further configurations available on request....

 Fittings for SafetyCaps / SafetyWasteCaps

SCAT

Fittings with integrated ferrule for SafetyCaps and SafetyWasteCaps.
Use the blind plugs to tighten connectors which are temporarily inactive or not in use....

 Safety Caps V2.0, GL 45

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.
Scope of suppy:
Safety Cap, air valve, change indicator, PFA fittings, PFA blind plug, labelling field...

 Safety Waste Caps, S 55

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.
Scope of supply:
...

 Adapters for exhaust filters

SCAT

Space problems in the lab? Use the adapters for the exhaust filter to gain more free space. Attach the exhaust filter in any position - perfect when dealing with lower installation heights....

 Flanged Tubing, PTFE, PA

Bohlender

Flanged PTFE tubing with black tube end fittings UNF ¼" 28 G made of PP and washers made of PA. The tubing is ready for use. Temperature resistant from 0 to +100 °C, pressure resistant up to 30 bar, universal chemical resistance....

 Inlet filter for solvents

SCAT

HPLC solvent filters for 3.2mm OD tubing....

 Safety Waste Caps, with mechanical level control

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.
The integrated float warns in time if the container is overfilled. Perfect for containers of opaque material, where the fill level is not visible from the outside....

 Safety Caps, GL/ S 40, with shut-off valve

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.
Scope of supply:
Safety Cap, air valve, change indicator, PFA fittings...

 Safety Caps, NS 29/32

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.
Scope of supply:
Safety Cap with NS 29/32, lock nut, air valve, change indicator, PFA fittings, PFA blind plug...

 Safety Waste Caps, S 51

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.
Scope of supply:
...

 Safety Waste Caps, S 70/71

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.
Scope of supply:
...

 Safety Waste Caps, S 90

SCAT

For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.
Scope of supply:
...

 Scrubber Adapter for Bottles, PTFE

Bohlender

Consisting of PTFE body with connecting nut and two lateral GL18 threaded necks, a 300mm long FEP inlet tube and a gas distributor with frit. Easy in- and outlet of gas by means of rigid-walled tubing (e.g. PTFE) which can be connected to the threaded necks using Bola Laboratory Screw Joints. Elastic tubing can be connected by means of hose connectors. Inlet tube can be individually shortened. Special feature: the body of the adapter can be turned independently from the connecting nut. This means, that the completely assembled adaptor can be removed and fixed onto another bottle without the risk of disarranging the tubing. Suitable for bottles with GL45 or GLS80 threads and capacities between 100ml and 5000ml....

 Thread adapters for SafetyCaps / SafetyWasteCaps, female / male thread

SCAT

Use SafetyCaps and SafetyWasteCaps also for bottles with GL40 or GL38 thread. Further adapters in different thread sizes are available on request....

 Exhaust filters V3.0, with change indicator

SCAT

The exhaust air filters are equipped with three different activated carbon layers, which bind acids and alkalis and adsorb organic solvent vapours. Depending on the required capacity, filter with different service lifes are available.

  • Filter media with a very high performance spectrum for acids and alkalis
  • Optimised for binding buffer solutions and solvent vapours
  • With splash guard
  • 1500 m²/g adsorption surface area
...

 Waste SafetyCaps

KEFO

Ideal for collecting liquid HPLC waste. The activated carbon in the exhaust filter binds all hazardous solvent vapours. Replacement of the exhaust filter after 6 months is recommended. Both capillaries and hose barbs can be inserted into the capillary connections.

  • With timestrip sticker
  • Caps and fittings made of PP
  • Body and hose barbs made of PTFE
...

Add to shopping cart