-
- General laboratory consumables
- Occupational safety, Security
- Analytical measurement and testing
- Stirring, Shaking, Mixing
- Sample preparation
- Distillation, separation, filtration
- Heating and cooling technology
- Liquid Handling
- Vacuum technology, Drying, Dry storage
- Optical instruments and microscopes
- Cleaning and sterilisation
- Environmental-, soil-, water-, food analysis
- Chromatography
- Cleanroom
HPLC columns
Guard columns for EC columns NUCLEODUR® C18 Isis, 3µm
C18 phase with special polymeric, crosslinked surface modification - USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%C
high steric selectivity
outstanding surface deactivation
suitable for
LC/MS due low bleeding characteristics
pH stability 1 - 10
broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins...
Accessories and replacement parts for EC columns
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart...
Guard columns for EC columns NUCLEODUR® C18 Gravity, 3µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases
available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications
Pore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C8
7, 10, 12 and 16µm particles for preparative separations on request...
VarioPrep columns for preparative HPLC C18 Pyramid, 5µm
stabel in 100 % aqueous eluent systems- USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 % C
7 and 10µm particles for preparative separations on request
interesting polar selectivity features
excellent base deactivation; suitable for
LC/MS due low bleeding characteristics...
VarioPrep columns for preparative HPLC NUCLEODUR® C18 Isis, 5µm
C18 phase with special polymeric, crosslinked surface modification - USP L1
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%C
high steric selectivity
outstanding surface deactivation
suitable for
LC/MS due low bleeding characteristics
pH stability 1 - 10
broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins...
VarioPrep columns for preparative HPLC NUCLEODUR® Sphinx RP, 5µm
distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for
LC/MS...
VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....
VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5, 100-7, 100-10, C18 ec
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....
VarioPrep preparative columns NUCLEDUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography....