Autoclaves

Filter

 Optima® FFAP capillary columns for GC

MACHEREY-NAGEL

polyethylene glycol 2-nitroterephthalate

close equivalent USP G25 / G35
polar phase
recommended for FAME, free carboxylic acids
similar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukol

for columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp....

 Optima® WAX capillary columns for GC

MACHEREY-NAGEL

polyethylene glycol 20000 daltons

USP G16
polar phase
recommended for solvent analysis and alcohols
suitable for aqueous solutions
similar phases: Premabond ® CW 20 M , DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax, 007-CW, BP20, AT-Wax, ZB-Wax...

 Capillary columns GC BP20

SGE (Trajan)

Polyethylene Glycol phase. GC column for analyses such as alcohol, free acids, fatty acid methyl esters, aromatics, solvents and essential oils. Suitable replacement for: Carbowax 20M, CP-Wax 52 CB, DB-WAX, Elite-WAX, HP-20M, HP-INNOWax RH-WAX, Rtx-Wax, Stabilwax, SUPELCOWAX 10, TG-WaxMS, VF-WAXms, ZB-WAX....

 Capillary columns GC BP21

SGE (Trajan)

Nitroterephtalic acid modified PEG. For low molecular weight acids, alcohols, aldehydes, acrylates and ketones. Suitable replacement for: DB-FFAP, HP-FFAP, Stabilwax-DA, CPWax-58CB.

  • Polar phase
  • Able to be solvent rinsed (water or methanol are not recommended for rinsing)
...

 Capillary columns GC BP5

SGE (Trajan)

5% Phenyl / 95% Dimethyl Polysiloxane. Low bleed. General purpose GC column for all routine analyses such as aromatics, pesticides, herbicides, hydrocarbons. Suitable replacement for: DB-5, Rtx-5, HP-5, Ultra-2, PTE-5, SPB-5, MDN-5, CP-Sil 8CB, VB-5, ZB-5, VF-5ms....

 Capillary columns BPX-Volatiles

SGE (Trajan)

Cyanopropyl Polysilphenylene. Polar phase. For environmental analyses, volatile organic substances, alcohol analyses and for the EPA method 624, USP G43 methods, 502.2, SW-846 and 8240 / 8260 methods. Suitable replacement for: DB-VRX, HP-624, OPTIMA 624, ELITE-624, 007-624, RTXVOLATILES, SPB-624, TRV1, CPSIL 13 CB, VOCOL, VB-624, CP-624....

 Capillary columns GC BPX90

SGE (Trajan)

90% Cyanopropyl Polysilphenylene-siloxane. For the fast separation of fragrances, aromatics, pesticides, PCB, isomers of fatty acid methyl esters.

  • Bonded phase
  • Highly polar
  • Thermally stable
  • Able to be solvent rinsed
...

 Capillary columns GC BP1 PONA

SGE (Trajan)

100% Dimethyl Polysiloxane. For the analysis of petroleum products. Suitable Replacement for: Petrocol DH, DB-Petro, HP-PONA, AT-Petro, Elite-PONA, ZB-1, 007-1-100-0.5F, Rtx-1PONA, CP Sil PONA.

  • Non-polar phase for PONA analysis
  • Detailed hydrocarbon analysis according to ASTM
  • Crosslinked and washable
  • Very high resolving power columns for complex samples
...

 Capillary columns GC BP1

SGE (Trajan)

100% Dimethyl Polysiloxane. General purpose GC column for all routine analyses such as hydrocarbons, aromatics, pesticides, phenol, herbicides and amines. Suitable replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.

  • Low bleed
  • Non-polar
...

 Capillary columns GC BP10

SGE (Trajan)

14 % Cyanopropylphenyl Polysiloxane. For analysis of organochlorine pesticides. Suitable replacement for: DB-1701, Rtx-1701, SPB-7, HP-1701, CP-Sil 19CB, 007-1701, PE-1701, SP-1701.

  • Low bleed
  • Highly inert
  • Able to be solvent rinsed
...

Add to shopping cart