-
- General laboratory consumables
- Occupational safety, Security
- Analytical measurement and testing
- Stirring, Shaking, Mixing
- Sample preparation
- Distillation, separation, filtration
- Heating and cooling technology
- Liquid Handling
- Vacuum technology, Drying, Dry storage
- Optical instruments and microscopes
- Cleaning and sterilisation
- Environmental-, soil-, water-, food analysis
- Chromatography
- Cleanroom
GC columns
Capillary columns GC BPX5
5% Phenyl Polysilphenylene-siloxane. General purpose GC column for routine gas chromatographic analysis. Suitable replacement for: DB-5, DB-5ms, DB-5.625, XTI-5, Rtx-5ms, Ultra-2, HP-5, HP-5MS, HP5-TA, SPB-5, MDN-5S, CP-Sil8CB, Rxt-Sil 5MS, AT-5ms, VB-5, ZB-5, VF-5ms.
- Very low bleed
- Non-polar
- Extremely inert
Capillary columns GC BPX70
70% Cyanopropyl Polysilphenylene-siloxane. Able to be solvent rinsed. Industry standard column for fatty acid methyl esters, carbonhydrates, pharmaceuticals, GC/MS applications. Suitable alternative to: DB-23, Rtx-2330, SP-2330, CP-Sil 88, SP2380, HP-23....
Capillary columns SolGel-Wax
Polyethylene Glycol (PEG) in a SolGel matrix. Suitable replacement for: DB-Wax, Rtx- Wax, Stabilwax, HP20M, HP-Wax, HP-INNOWax, Supelcowax-10, AT-Wax, Nukol, CP, Wax 52CB, VB-WAX, ZB-WAX.
- Robust high-temperature column.
- Polar phase
- Low bleed and inert
GC Capillary columns HYDRODEX β-6TBDM
cyclodextrin derivatives with high melting point:
for GC-enantiomer separation diluted with polysiloxanes
Heptakis-(2,3-di-O-methyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for γ-lactones, cyclopentanones, terpenes, esters, tartrates.
...
GC Capillary columns HYDRODEX β-TBDAC
cyclodextrin derivatives with high melting point:
for GC-enantiomer separation diluted with polysiloxanes
Heptakis-(2,3-di-O-acetyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for alcohols, esters, ketones, aldehydes, δ-lactones.
...
GC Capillary columns LIPODEX® E
LIPODEX® cyclodextrin phase for enantiomer separation
base material: cyclic oligosaccharide consisting of eight glucose units bonded through α-1,4-linkages (y-cylodextrin) regioselective alkylation and acylation of the hydroxyl groups leads to a lipophilic phase, which is well suited for GC enantiomer analyses; important advantage: many compounds can be analysed without derivatisation (however, for certain substances enantioselectivity can be favourably influenced by formation of derivatives)...
OPTIMA® 1 high performance capillary columns for GC
100% dimethylpolysiloxane
nonpolar phase separation of components according to boiling points thick film columns ≥3µm film are especially recommended for solvent analysis.
Similar phases: Permabond
® SE-30, OV-1, DB-1, SE-30, HP-1, SPB-1, CP-Sil 5 CB, Rtx-1, 007-1, BP1, MDN-1, AT-1, ZB-1, OV-101....