BOD
With vent, level display and stopcock. Blue solid-coloured (for light protection). Additional lid for easier cleaning.VD series: With distributor frits and compressed air connection without cooling coil.VDT series: With distribution frits and compressed air connection, with internal stainless steel cooling coil and connection for recirculation thermostat. 2x connections inlet / outlet cooling water: 2x ¾" with screwed on ½" connection with nozzle approx. 13 mm. Third connection for ventilation with 6 mm nozzle.
OxiTop® PT, test equipment for negative pressure and leak testing for all OxiTop measuring heads
The Hei-PLATE Mix'n'Heat Core series with heating consists of models Hei-PLATE Mix'n'Heat Core, Hei-PLATE Mix'n'Heat Core+ and Hei-PLATE Mix'n'Heat Core+.With patented Kera-Disk® top plate made of anodized aluminum and fireproof aluminum die cast housingFastest heating times thanks to 800 W (at 230 V), the built in PID controller guarantees precise control without overshooting the temperatureSimple operating conceptLarger distances between the heating plate and knobs for additional protection against burnsLiquids are safely dissipated from the deviceA carrying support on the underside ensures safe transportConnections on the back are protected by a flapWith connection for optional temperature sensor Pt 1000Compatible with EKT Hei-Con contact thermometers for external controlling and display of actual temperature valuesScope of supply: Hei-PLATE Mix'n'Heat Core+, PT 1000 (V4A)
Iincl. 2 x nozzles, 2 x VS25 screwing sets for nozzle, 1 x GK 600 rubber sleeve, 2 x SEP25 septum for nozzle, 2 x STH25 support for nozzle
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readings
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 6 x measuring head grey, 6 x measuring head blue
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 1 x measuring head grey, 1 x measuring head blue
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 3 x measuring head grey, 3 x measuring head blue, 6 sample bottles, 6 rubber quivers, 6 magnetic stirring rods
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 3 x measuring head grey, 3 x measuring head blue
Professional digital multiparameter meters for mobile measurement, wireless preparation, data logger manually or automatically (timed). Easy to clean with a soft brush under water jet. The Multi 3620 IDS with two universal measurement channels is suitable for all WTW IDS pH, ORP, dissolved oxygen sensors, conductivity cells and turbidity sensors, whether connected to cable or wireless. Documentation of meter and sensor data. User control over MultiLab® users. With USB-A and Mini USB-B interface and colour display.Also for controlling OxiTop® IDS.Scope of supply: Instrument, short manual, CD-ROM, rechargeable batteries, driver software for USB, cable, power supply, protection SM Pro, IDS WLM-M module
Professional digital multiparameter meters for mobile measurement, wireless preparation, data logger manually or automatically (timed). Easy to clean with a soft brush under water jet. The Multi 3630 IDS with three universal measurement channels is suitable for all WTW IDS pH, ORP, dissolved oxygen sensors, conductivity cells and turbidity sensors, whether connected to cable or wireless. Documentation of meter and sensor data. User control over MultiLab® users. With USB-A and Mini USB-B interface and colour display.Also for controlling OxiTop® IDS.Scope of supply: Instrument, short manual, CD-ROM, rechargeable batteries, driver software for USB, cable, power supply, protection SM Pro, IDS WLM-M module
Rubber Gasket GLP 6.5cm
These Stirring platforms have been specially developed for BOD measurement with the OxiTop® system. Software-controlled speed regulation prevents the magnetic stirrer bar from getting caught or wobbling. The speed is selected so that an optimal gas exchange with the sample takes place. The stirrer is maintenance-free and non-wearing as it contains no moving parts.The IS 6-Var model has been specially developed for use with large measuring vessels and has space for 6 measuring vessels. Its outer dimensions are identical to those of the IS 12. Speed 180 to 450 rpm.
CLP-Info
- H360FD: May damage fertility. May damage the unborn child.
- P201: Obtain special instructions before use.
- P202: Do not handle until all safety precautions have been read and understood.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
- P405: Store locked up.
- P501: Dispose of contents/container to
Sensor calibration set for BSB/BOD sensor (no dan. goods)
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubator
OxiTop®-IDS wireless measuring head with Bluetooth® LE technology for operation with Multi 3620 IDS or Multi 3630 IDS. For routine BOD readings also operable without IDS multiparameter instrument. OxiTop®-IDS/B with enhanced pressure range up to 1500 hPa and H2S resistant pressure sensor for biogas measurement.Memory for 360 measuring points3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionFor routine BOD readings measurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsIntermediate values available
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H360FD: May damage fertility. May damage the unborn child.
- P201: Obtain special instructions before use.
- P202: Do not handle until all safety precautions have been read and understood.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
- P310: Immediately call a POISON CENTER/doctor/
- P390: Absorb spillage to prevent material damage.
- P405: Store locked up.
- P501: Dispose of contents/container to
BOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Measuring principle: respirometric, electronic pressure sensorMeasuring ranges: 0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 - 4000 mg/l O2Application: BOD5/BODF/OECD301FScope of supply:BD 600, complete unit with 6 sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 sample bottles6 rubber gaskets6 magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualRemote control
BOD bottle 300ml, 69 mm Ø x 165 mm without stopper, Unnumbered pack of 24 (227498)
Bottle DBO 60 ml pack of 36