Filter products
Sample preparation
CHROMABOND Filter elements for 6 ml glass columns, pack of 250
Octadecyl modified silica phase for SPE, endcappedBase material silica, particle size 45 µm for C18 ec, specific surface 500 m²/g, pH stability 2 to 8. Octadecyl phases, endcapped, carbon content 14 % very non-polar, hydrophobic interactions with a wide variety of organic compounds. Advantageous for clean-up of samples with large structural variations (polarity differences).Recommended applications: non-polar compounds, aflatoxins, amphetamines, antibiotics, antiepileptics, barbiturates, caffeine, drugs, preservatives, fatty acids, nicotine, PAHs, pesticides, PCBs, heavy metals, vitamins. Very well suited for desalting of samples.
Combination phase for SPE of hydrocarbons from water acc. to DIN H53 / ISO DIS 9377-4Special combination phase of sodium sulphate and Florisil®.Recommended application: hydrocarbons from drinking, surface and waste waters.
Combination phase for SPE analysis of PAH from water containing humic acidsSpecial combination phase: aminopropyl phase for removal of interfering humic acids, octadecyl phase for enrichment of PAH.Recommended application: PAH from water containing humic acids.
Extraction mixtures for sample preparation for determination of pesticides in food samples.MACHEREY-NAGEL offers a number of individually weighed and pre-mixed buffers and extraction mixtures, specially composed for different sample matrices.Mix I and Mix II are extraction mixtures, Mix III to Mix VI are clean-up mixtures.The food samples will be extracted with either Mix I or Mix II.Afterwards they will be purified with one of the following mixtures:Mix III (samples with low fat content; e.g. apples, strawberries),Mix IV (moderate content of chlorophyll and carotinoids; e. g. carrots, lettuce),Mix V (high content of chlorophyll and carotinoids; e. g. bell peppers, spinach),Mix VI (high fat content; e. g. avocados).Every mix is prepacked in a 15 ml centrifuge tube. Pack of 50 pieces.
Unmodified silica phase for SPEUnmodified, weakly acidic silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, very polar, adsorbs humidity from air, for this reason it should be kept well closed and if necessary dried before use due to its high affinity for polar compounds it should not be conditioned with polar (e.g. methanol) or water-containing solvents.Recommended applications: aflatoxins, chloramphenicol, pesticides, steroids, vitamins.
For simultaneous preparation of up to 12 or 24 samples, replacement parts and accessories for special applications.Vacuum manifold complete consists of: glass cabinet with lid and lid gasket, removable needles on lower side of lid, vacuum gauge, control valve, valves and caps, variable rack.
Extraction and clean-up mixtures for sample preparation in the pesticide analysis of vegetable foodstuffs according to EN 15662 using GC/MS or LC/MS after acetonitrile extraction and purification using the dispersive SPE-QuEChERS method.The samples are first extracted with Mix A. Purification is done with one of the following mixtures:Mix B (Clean-up mixture for fruits and vegetables with low fat content, e.g. apples, strawberries)Mix C (Clean-up mixture for fruits and vegetables with high fat content, containing oil/wax, e.g. avocados)Mix D (Clean-up mixture for moderately chlorophyll/carotenoid-containing fruits and vegetables, e.g. carrots, salad)Mix E (Clean-up mixture for fruits and vegetables with high chlorophyll/carotenoid content, e.g. sweet peppers, spinach)If required, add ceramic homogenising beads for better mixing.Mix A contains a bag with the required amount of mixture and a 50 ml empty tubeMix B, C, D and E are pre-weighed into a 15 ml tube
Special phase for SPE analysis. For enrichment of PFAS from water, textiles and sediments (contaminated soils). Polymeric combination phase with weak anion exchanger, highly porous, spherical particles.
CHROMABOND Columns Drug BIGpack volume: 3 ml, content of sorbent: 200 mg, PP with, PE-filterelements, 5 bags with 50 pcs.
CHROMABOND columns HLB (30 µm, fine grained) particle size: 30µm volume: 3mL, content of sorbent: 60mg, PP, with PE filter elem.,pack of 30
Chromabond columns HLB (60 µm), 3 mL,500mg PP, with PE filter elements, pack of 30
CHROMABOND Columns HLB 60 µm volume: 3 ml, content of sorbent: 60 mg, PP, with PE-filterelements, pack of 30
CHROMABOND Flash DL 120 Direct Load Cartridges
CHROMABOND Flash DL 200 Direct Load Cartridges
CHROMABOND Flash DL 25 Direct Load Cartridges
CHROMABOND Flash DL 330 Direct Load Cartridges
CHROMABOND Flash Starter kit consist of: 1 Tube, material: PTFE, OD: ⅛″, ID: 1,5 mm, length: 3 m 5 Nut, material: PP, connection: ¼″-28 5
CHROMABOND PP tank SPE for vaccum manifold for 24 columns (REF 730151N) pack of 2
CHROMABOND PP-Tank for vaccum manifold for 12 columns pack of 2