Tintometer
BOD measurement system BD 600
Product number:
6268048
Quantity per packaging unit:
1 Stück
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H360FD: May damage fertility. May damage the unborn child.
- P201: Obtain special instructions before use.
- P202: Do not handle until all safety precautions have been read and understood.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
- P310: Immediately call a POISON CENTER/doctor/
- P390: Absorb spillage to prevent material damage.
- P405: Store locked up.
- P501: Dispose of contents/container to
BOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.
Scope of supply:
- Measuring principle: respirometric, electronic pressure sensor
- Measuring ranges: 0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 - 4000 mg/l O2
- Application: BOD5/BODF/OECD301F
Scope of supply:
- BD 600, complete unit with 6 sensor heads and control unit with batteries
- Power supply unit incl. Y-cable for common power supply of BD 600 and stirring unit
- Inductive stirring unit
- 6 sample bottles
- 6 rubber gaskets
- 6 magnetic stirring rods
- 1 overflow flask, 157 ml
- 1 overflow flask, 428 ml
- 1 bottle, 50 ml potassium hydroxide solution
- 1 bottle, 50 ml nitrification inhibitor solution
- 1 instruction manual
- Remote control
| Battery/ rechargeable battery: | 3 x C, AlMn |
|---|---|
| Depth: | 230 mm |
| Dimensions (WxDxH): | 181 x 230 x 375 mm |
| Height: | 375 mm |
| IP code: | IP 51 |
| Measuring time: | 28 d |
| No. of measuring positions: | 6 |
| Package size: | 1 Stück |
| Power supply: | 100 ... 240 V, 50/60 Hz |
| Type: | BD 600 |
| Type of auxiliary energy: | Battery/mains connection |
| Width: | 181 mm |
| Packaging type: | - |
| Document | Download |
|---|---|
| Safety Data Sheet |