Filter products
BOD
CLP-Info
- H360FD: May damage fertility. May damage the unborn child.
- P201: Obtain special instructions before use.
- P202: Do not handle until all safety precautions have been read and understood.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
- P405: Store locked up.
- P501: Dispose of contents/container to
OxiTop® PM, BSB-Tesst equipment pack á 10 tablets no dangerous good
Karlsruher BOD bottle with NS19 conical ground joint.
The special bottle neck of the Karlsruhe bottles absorbs the water which is displaced by the stopper of the electrode. This construction guarantees clean working and ensures at the same time that the test results are not adulterated by unwanted entry of oxygen into the samples.
Nitrification inhibitor flask with 50ml liquid
Winkler pattern. Soda-lime glass.For determination of dissolved oxygen in water. The measured capacity is specified to ± 0,01ml. With white labelling area. Solid, bevelled glass stopper, secured with an accessory spring clip. Each bottle is adjusted to the relevant stopper. Stoppers and bottles are therefore not interchangeable. Each bottle and its stopper is marked with a unique, matching identification number.
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubator
BOD measurement,for 12 places,OxiTop IS12 UN 1823, 8, II, (E)
With NS 19 cone glass stopper.
BOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Measuring principle: respirometric, electronic pressure sensorMeasuring ranges: 0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 - 4000 mg/l O2Application: BOD5/BODF/OECD301FGLP conformityScope of supply:BD 600, complete unit with 6 sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 sample bottles6 rubber gaskets6 magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualRemote control
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Easy-to-use, respirometric measuring system for determining the biological oxygen demand (BOD). The method is based on changes of pressure in a closed system using measuring heads attached to the sample bottles. The BOD can be determined simultaneously in up to 6 or 12 samples.No dilution of the sample requiredDirect reading of the BOD, the time course and the intermediate values on the graphical display of the measuring headsInput of the used sample volume directly at the measuring headMonitoring time between 1 and 7 daysPermanent display of the current status at each measuring headColoured measuring heads with adjustable, numerical sample identificationScope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12An incubator is required to operate the OxiTop®-i IS. Please order separately.
Respirometric measuring system for 6 measuring heads for determination of aerobic soil respiration, OxiTop®-IDS B6M-2.5 acc. to AT4 guideline. These sets are suitable for forecast, survey and monitoring of clean-up operations as well as measurement of bio-degradation of pesticides, fungicides, insecticides and fertilizers for example.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Bluetooth® connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsMeasurement duration selectable (0.5 hours to 180 days)Please order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.Scope of supply: 6 measuring heads, 6 sample bottles PF45/500 (500 ml), 6 adapters OxiTop® AD/SK
These tests quantify the biological degradability of chemicals.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Respirometric degradability tests according to OECD 301F/DIN EN ISO 9408Versatile measurement by using the BOD special modeMeasurement duration selectable (0.5 hours to 180 days)Bluetooth® connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsPlease order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.OxiTop®-IDS Set 6 also for BOD self-monitoring measurementsScope of supply: 6 x OxiTop®-IDS measuring heads, 6 x bottles PF600 (510 ml), 6 x rubber sleeves, nitrification inhibitor, overflow measuring flask, 6 x magnetic stirring bars, stirring bar retriever, stirring platform IS 6
Sample bottle glass BSB-5
Sensor heads for the reliable determination of 90 to 4000 ppm BOD.The sensor heads are screwed directly onto the BOD bottlesAutomatic storage of 5 results in 24-hour intervalsMeasured readings in mg/l (ppm) can be read directly on the sensor at any timeProtected against splashing water (IP 54)
Sensor heads for the reliable determination of 90 to 4000 ppm BOD.The sensor heads are screwed directly onto the BOD bottlesAutomatic storage of 5 results in 24-hour intervalsMeasured readings in mg/l (ppm) can be read directly on the sensor at any timeProtected against splashing water (IP 54)500 ml brown glass bottle with BOD sensor, KOH reservoir, stirring rod.
Measuring systems for the reliable determination of 90 to 4000 ppm BOD. Complete with sensor heads and multi-position magnetic stirrer.The sensor heads are screwed directly onto the BOD bottlesAutomatic storage of 5 results in 24-hour intervalsMeasured readings in mg/l (ppm) can be read directly on the sensor at any timeProtected against splashing water (IP 54)Scope of supply BOD sensor system 6: 6-position magnetic stirrer, each 6 BOD sensors incl. batteries, 500 ml brown glass bottles, KOH reservoirs and magnetic stirring rodsScope of supply BOD sensor system 10: 10-position magnetic stirrer, each 10 BOD sensors incl. batteries, 500 ml brown glass bottles, KOH reservoirs and magnetic stirring rods
Compact temperature cabinets with internal sockets for the use of OxiTop® IS 12 stirring platforms.Incubation conforming to standardsSuited for BOD, OECD 301F, soil respiration, anaerobic degradationTemperature adjustable in steps of 1 K between 10 and 40 °CEco-friendly refrigerant R600aNote: The necessary temperature constancy will only achieved in combination with the samples.Model with insulation glass door allows visual control of the OxiTop® heads without opening the door.
Compact temperature cabinets with internal sockets for the use of OxiTop® IS 12 stirring platforms.Incubation conforming to standardsSuited for BOD, OECD 301F, soil respiration, anaerobic degradationTemperature adjustable in steps of 1 K between 10 and 40 °CEco-friendly refrigerant R600aNote: The necessary temperature constancy will only achieved in combination with the samples.
Compact temperature cabinets with internal sockets for the use of OxiTop® IS 12 stirring platforms.Incubation conforming to standardsSuited for BOD, OECD 301F, soil respiration, anaerobic degradationTemperature adjustable in steps of 1 K between 10 and 40 °CEco-friendly refrigerant R600aNote: The necessary temperature constancy will only achieved in combination with the samples.Model with insulation glass door allows visual control of the OxiTop® heads without opening the door.
Compact temperature cabinets with internal sockets for the use of OxiTop® IS 12 stirring platforms.Incubation conforming to standardsSuited for BOD, OECD 301F, soil respiration, anaerobic degradationTemperature adjustable in steps of 1 K between 10 and 40 °CEco-friendly refrigerant R600aNote: The necessary temperature constancy will only achieved in combination with the samples.