Filter products
Photometric analyses (cuvette tests)
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H372: Causes damage to organs through prolonged or repeated exposure .
- H373: May cause damage to organs through prolonged or repeated exposure .
- P234: Keep only in original packaging.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P264: Wash thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P314: Get medical advice/attention if you feel unwell.
Single-parameter photometer for analysing various parameters in water treatment. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable.Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsOne-point calibrationProgramming option for one customised methodNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupScope of supply: Photometer, 3 x 24 mm round glass cuvettes with lid and sealing ring, screwdriver, 3 x stirring rods, 10 ml syringe, cleaning brush, USB-C to USB-A cable, carrying case, 2 x AA batteries, operating instructions, reagents
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H372: Causes damage to organs through prolonged or repeated exposure .
- H373: May cause damage to organs through prolonged or repeated exposure .
- P234: Keep only in original packaging.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P264: Wash thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P314: Get medical advice/attention if you feel unwell.
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
Single-parameter photometer for analysing various parameters in water treatment. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable.Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsOne-point calibrationProgramming option for one customised methodNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupScope of supply: Photometer, 3 x 24 mm round glass cuvettes with lid and sealing ring, screwdriver, 3 x stirring rods, 10 ml syringe, cleaning brush, USB-C to USB-A cable, carrying case, 2 x AA batteries, operating instructions, reagents
Modern, mobile photometers for rapid, reliable water testingAll important water analysis parameters from Aluminium to Zinc are covered by these two devices. Combined with the high precision of Lovibond® reagents, a reliable and quick analysis of water samples is guaranteed. Reagent tablets, powder reagents, liquid reagents, or cuvette tests are used depending on the method. Please order separately. Six long-lasting LEDs serving as a light source in combination with interference filters guarantee the highest precision. The devices are designed without moving optical parts and thus have a maintenance-free measuring unit.Highest/reproducible precision with interference filterDisplay with background lightingMore than 120 pre-programmed methodsAutomatic selection of wavelengthUser guidance in German, English, French, Spanish, Italian, Portuguese, PolishMore than 35 user-specific methods possibleWaterproof housing (as defined in IP 67)Handheld format, portableBuffer for up to 500 data recordsBluetooth interface for connection to smart phones and tabletsCost-free iOS®- and Android™-App for data management and email deliveryScope of supply: The instrument is supplied complete and ready-to-use in a carrying case, incl. 4 batteries, 3 vials diam. 24 mm, 3 vials diam. 16 mm, 1 adapter each for 16 mm and 13 mm vials.Please order reagents separately.
With Dual Beam Technology. The MultiDirect is a modern, microprocessor-controlled photometer with ergonomically designed keypad and large-format graphic display. It is equipped with a wide range of pre-programmed methods (e.g. ammonia, COD, phosphate) based on the proven range of Lovibond® tablet reagents, liquid reagents, vial tests and powder reagents. The calibration and software-supported control options mean that the unit is also suitable for use as a testing instrument. The seven standard rechargeable batteries (supplied) ensure easy mobile use.Wide range of pre-programmed methodsLarge, graphics displayRS232 interfaceSuitable for use with standard rechargeable batteriesUpdates for new methods and languages via the Internet1000 data set memoryCustom method recall is also possibleScope of supply: MultiDirect, ready-to-use incl. 7 x rechargeable batteries and battery charger for 100 - 240V, 3 each 24mm and 16mm cuvettes, 16mm cuvette adapter, 3 x syringes, 1 x 100ml plastic beaker and case with waterproof insert. Without reagents and without battery (please order separately).Verification Standard Kit: The verification standard kit for the MultiDirect is designed to reassure the user about the accuracy and the reliability of the results. The shelf life of the standard kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Measurements are taken in mAbs.
CLP-Info
- H226: Flammable liquid and vapour.
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P233: Keep container tightly closed.
- P234: Keep only in original packaging.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Photometer for the analysis of determined parameters in drinking, industrial and waste water. Different models are available for common analyses as well as for special applications.Ergonomic, waterproof designAccurate, reproducible measurement resultsUser calibration and single point calibrationMeasurement results are displayed directly in ABS or %TZero value remains valid for all tests with the same sample thanks to the one-time zero (OTZ) functionAutomatic storage of measured values with time and date stamp and optional data transfer (IRiM module)Bluetooth® interfaceScroll memoryAutomatic shutdownAdjustment function displayScope of supply: Photometer, carrying case, reagents for 100 tests, cuvettes, batteries, standard accessories
CLP-Info
- H226: Flammable liquid and vapour.
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P233: Keep container tightly closed.
- P234: Keep only in original packaging.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Benchtop devices suitable for mobile use. For precise water control through high-precision optics and high-quality interference filters with long-term stable LEDs as light sources.Automatic shutdownReal time clock and dateAdjustment function displayIlluminated LCD-display
powder test CI-2 TP TP 0.0-5.0 mg/l CI2
CLP-Info
- H272: May intensify fire; oxidiser.
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- H335: May cause respiratory irritation.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P313: Get medical advice/attention.
Test set, phosphate 5-60 mg/l, 690nm UN 1444, 5.1, III, (E)
CLP-Info
- H318: Causes serious eye damage.
- P262: Do not get in eyes, on skin, or on clothing.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Hydrazine test powder 30g
REAGENZTABLETTEN DPD NR.1 / RAPI
CLP-Info
- H226: Flammable liquid and vapour.
- H319: Causes serious eye irritation.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P233: Keep container tightly closed.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P337+P313: If eye irritation persists: Get medical advice/attention.
The reference standards are used to check the photometric detection accuracy and reproducibility of measurement results. Adjustment of the photometers is not possible with the reference standard kits. When checking the photometers with the reference standard kit, the appropriate method is selected and the measured value in mg/L is compared with the reference value of the standard kit. The shelf life is two years from the date of manufacture if used and stored properly.For instruments with tablet reagent.
COD measurement without reagents.The spectrophotometer of the photoLab® 7000 Series are universally usable and offer complete photometricfunctionality with lauded user-interface and guidance on a brilliant HD 7"" color display. Pioneering is the optical reagent-free measurement (OptRF) of COD, Nitrate and Nitrite. No time-consuming digestion and no harmful chemicals required.Proven routine analysis for waste and drinking water, aquaculture, food & beverage, environmental monitoring and productionCost saving reagent-free OptRF measurementUniversal for industrial, research and educational useLab quality in the field: 4,5 kg light weight, with car battery and field case optionLinking lab with Online-system WTW® IQ SENSORNET via IQ LabLinkFor 16 mm round cuvettes and 10, 20 and 50 mm rectangular cuvettes with automatic recognitionMemory for 5000 values, spectra and kinetics approx. 40 MB, equivalent to approx. 500 spectra (300-900 nm) and 400 kinetics with 150 measured valuesMore than 200 programmed methods, 1000 user defined methods, 20 profiles each for kinetics and absorption spectrum, extensive programming optionsRoutine Analysis:More than 250 programs for commercial test kits, standard parameters, direct readings of coloration, SAK, etc. as well as user-defined programming of routinesBarcode recognition for tests in vials and rectangular cells and automatic cell recognition for 16, 10, 20 and 50 mm without adapter and automatic measurement range selectionUp to three parallel timersOptional PC-Software Package for Brewery and color measurement from CIE to YellownessSpectral and universal analysis from 190 to 1100 nm:Spectral scans in various nm-steps, 700-2000 nm/minKinetics and multi-wavelength readings including special methods like chlorophyll and ADMI color measurementExtensive programming tools for multistep and multi-wavelength functions with user guidanceAQA: Multi-level user-friendly AQA functions with administration tools and comprehensive checking aids for meter and reagents.Data Management:Measurement data, PDF documents, spectra and kinetics data, with data filter for pre-selected data managementExternal barcode reading option for uncoded test kits and sample IDOptional: PC-Software for GLP compliant data management
Chemical digestion of samples is required for the photometric determination of COD, TOC, total chromium, total phosphate and total nitrogen. The required temperatures and reaction time can be selected by using the membrane keypad of the reactor RD 125. The unit works at three different temperatures (100/120/150 °C) and three pre-set reaction times (30/60/120 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm. The RD 125 reactor is fitted with 24 holes for 16 mm diameter vials. Power supply 230 V, 50-60 Hz or 115 V, 50-60 Hz (switchable).
CLP-Info
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- P284: [In case of inadequate ventilation] wear respiratory protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P362+P364: Take off contaminated clothing and wash it before reuse.
- P501: Dispose of contents/container to
For the determination of TOC in water samples. The screw couplings make it easier to screw the cuvettes together. They ensure that the digestion is possible in a closed system.
CLP-Info
- H226: Flammable liquid and vapour.
- H319: Causes serious eye irritation.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P233: Keep container tightly closed.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P337+P313: If eye irritation persists: Get medical advice/attention.
Verification standards for checking the accuracy and reliability of measurement results.
Adapter for 13mm cuvettes, black
Adapter for 16mm cuvettes, black
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H411: Toxic to aquatic life with long lasting effects.
- EUH031: Contact with acids liberates toxic gas.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P264: Wash face, hands and any exposed skin thoroughly after handling.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P337+P313: If eye irritation persists: Get medical advice/attention.
- P391: Collect spillage.
Ammonium cuvette test measuring range 47-130 mg/l NH4-N *
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H411: Toxic to aquatic life with long lasting effects.
- EUH031: Contact with acids liberates toxic gas.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P264: Wash face, hands and any exposed skin thoroughly after handling.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P337+P313: If eye irritation persists: Get medical advice/attention.
- P391: Collect spillage.
Ammonium cuvette test measuring range 2.0-47 mg/l NH4-N *
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H411: Toxic to aquatic life with long lasting effects.
- EUH031: Contact with acids liberates toxic gas.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P264: Wash face, hands and any exposed skin thoroughly after handling.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P337+P313: If eye irritation persists: Get medical advice/attention.
- P391: Collect spillage.
Ammonium cuvette test measuring range 1.0-12 mg/l NH4-N *