Filter products
Electrodes and accessories for oxygen determinatio
Tripodset with arm and Electrode holder for screwing on the devices of the Lab and ProLab family
VisiFerm DO ESC 325 HO Oxygen electrode, 325 mm, VP8, 4 ppb to 25 ppm (DO)
2-electrodes measuring cells LRD 01-7 with thread and cable 7m
9 way serial cable (not for use with 3505)
Oxygen-electrode 10 m cable
Maintenance Kit consists of membrane cap and Micro SD card with software and calibration data.
D.O. sensors with continuous measuring accuracy. Selction of models with an automatic self diagnosis system, a shorter response time and different cable lengths. All models are supplied with accessories box and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).TriOxmatic® 700: For biological cleaning steps (wastewater treatment plants).With automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Medium response time of t90 < 180 s. Only available as retrofit fitting for analog converters of the Ecoline® and QuadroLine® series. Digital version still available (IQ Sensor Net System 181).TriOxmatic® 690: For measuring tasks in wastewater/water. Economic model without self diagnosis.TriOxmatic® 701: With increased resolution for the measurement of residual oxygen in the denitrification. Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations.Scope of supply: Sensor incl. accessories box with membrane heads, electrolyte solution, cleaning solution, cathode cleaner
Changing cap SC-FDO® 925
Sensor cable in high quality.
Electrolyte solution ELY/NH
Gasdichte Spritze 2.5MDF-LL-GT 2,5 ml
Robust oxygen sensor with an integrated NTC temperature sensor for the IQ Sensor Net to regulate biological cleaning steps. Free of calibration and flow, DIN-compliant. Suitable for use with an overpressure of up to 10 bar. Response time (at 25 °C) t90 < 150 s.
pH buffers for the daily and high-precision calibration and adjustment of pH electrodes.Accuracy (±0.02) and reproducibility help to optimise the pH value and thus increase product quality and yieldTraceable to NIST and PTB standard reference material
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Spare electrolyte KOH 100, 100ml for SensoDirect Oxi UN 1814, 8, II, (E)
Leak-proof and robust pH probe for pH meter 206-pH2, insensitive to contamination, with maintenance-free gel electrolyte and gel storage cap.
Platinum cathode/lead anode.
Measuring vessel MG 1.0/E, 1000 ml
Active terminal box KI/pH-MIQ/S IP 65, 240x165x95mm