Electrodes and accessories for oxygen determinatio
3 exchange diaphragm heads for StirrOX G, WP 3-ST
Sample flasks PF 600, brown
Combination oxygen, conductivity sensor ConOx-3
Cable AS/IDS-100 100 m
Cathode cleaner (abrasive foil) for oxygen sensors
Changing cap SC-FDO® 925
These standards are ideal for use as control standards to verify that correct analysis for COD has taken place. Extensive range (10 to 60000 ppm), NIST traceable, 2 years shelf-life. Bottles of 500 ml.
For the qualified calibration of conductivity measuring systems according to ISO. The reference temperature of the calibration solution is 25 °C. Highest precision of ±0.5 %. Traceable to international standards: SRM by NIST. With quality certificate.
4-electrode measuring cells made of graphite with integrated temperature sensor and fixed cable. Ideal for samples with normal and high conductivity.
For connecting electrodes with built-in temperature sensors and MultiPin™ plug head. Suitable for a wide range of measuring devices from different manufacturers.
For Dissolved oxygen meters FiveGo™ FG4. Galvanic sensor with integrated temperature sensor NTC 30 kOhm for the measurement of dissolved oxygen.
Electrolyte solution to refill the liquid filled reference system of pH electrodes.
Electronic solution ELY/G, 50 ml
CLP-Info
- H314: Causes severe skin burns and eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Potassium hydroxide solution.
CLP-Info
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Membrane covered galvanic dissolved oxygen for measurement of water and aqueous solutions. Low maintenance and without polarization time. The CellOx® 325 is a dissolved oxygen sensor with built-in temperture compensation by a NTC 30 kOhm sensor and membrane leakage monitoring for field and laboratory applications. It has a fast response (t99<60 s) and a low-maintenance operation. The application ranges from surface water, waste water treatment, BOD measurement to industrial and special applications. An electrolyte filling is sufficient for up to 6 months service life. The calibration vessel is included in the delivery.For Oxi 3xx, Oxi 3xxi, ProfiLine Oxi 197, ProfiLine Oxi 197i, ProfiLine Multi 197i, Multi 340i, Oxi 3205, Oxi 3210, Oxi 3310, ProfiLine Oxi 1970i, ProfiLine Multi 1970i, inoLab®.
Optical IDS D.O. sensor for portable MultiLine® IDS and InoLab® Multi IDS benchtop meters. Measures the dissolved oxygen according DIN ISO 17289:2014-12. For applications in the lab and in process, outdoor and waste water treatment plants. Low maintenance (t99 < 60 s). No oxygen consumption, with inclined membrane for avoiding air bubbles. Factory calibrated membrane with smart chip. Built-in NTC 30 kOhm temperature sensor.
The portable hand-held measuring instrument SD 315 Oxi meets the daily requirements for a robust and reliable instrument for the determination of dissolved oxygen in aqueous media. The Clark oxygen sensor with integrated temperature probe enables immediate measurements without time-consuming run-in time (polarisation time).Simple calibration against air or according to DIN EN ISO 5814Alarm function with adjustable limitsAutomatic pressure and temperature compensationAuto Hold FunctionAutomatic switch-off individually selectable from 1 to 120 minBacklit LCD displaySensor status display in % after each calibrationSalinity correctionParameter: dissolved oxygen (O2), O2 concentration in mg/l, O2 saturation in %, temperature in °C/°FBattery status indicatorFlexible stand at the rear allows the unit to be set up or fastened to a beltData transfer and evaluation via software possibleScope of supply: Instrument, protective covering, electrode holder, carrying case, galvanic oxygen sensor with 10 m cable, KOH refill electrolyte, spare membrane, calibration bottle with sponge, batteries, manual
CLP-Info
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
For use with Oxi 3xxi, ProfiLine Oxi 1970i, ProfiLine 3205, 3210, 3310.Membrane-covered oxygen sensor with low flow requirement and removable cage guard, for field applications (fish farm revival pools) and for educational purposes.Ready to measure - no polarisation timeIMT compensation via two integral temperature sensorsService life with one electrolyte filling approx. 6 monthsMinimal flow requirementNo zero currentSensor is watertight (IP 68 - 2)Standard with 3m cable and watertight plugStandard with calibration/storage vessel OxiCal® -DStandard with cage guard SK-D
Sensor for polarographic oxygen measurement with high accuracy and repeatability. For use in laboratory, field and industry. Robust construction. Diaphragm mechanically protected by steel mesh, shaft made of glass-fibre reinforced PPS. With integrated temperature sensor.InLab® oxygen sensors are designed for use with the SevenExcellence™ multi-channel tabletop meter and the portable SevenGo™ 6 metersInLab®-ISM oxygen sensors are equipped with Intelligent Sensor Management, which enables simple calibration in the air and permanent monitoring of the sensor statusDesigned for use with the SevenExcellence™ multi-channel tabletop meter and the portable SevenGo™ 68 dual-channel instruments.
For inoLab® Oxi 730, ProfiLine 197i/1970i, inoLab® 740 Oxi, inolab Oxi 7310. Self-stirring oxygen sensor.Single-handed useHigh reproducibilityReady for immediate use, no polarisation period necessaryExtremely low internal consumption of oxygen by the electrodeNo zero point calibration necessary6 months operation with one electrolyte fillingIMT function compensationMembrane leakage monitoring, damaged membranes are indicatedScope of supply: Oxygen sensor, OxiCal®-ST calibration and storage vessel, 3 exchange membrane heads, electrolyte, abrasive foilPlease order cleaning solution separately.