Skip to main content Skip to search Skip to main navigation
pH electrode with chemically resistant PEEK shaft and open junction for general applications in the laboratory and outdoors.

  • ARGENTHAL™ reference system with silver ion trap
  • Solid XEROLYT® reference electrolyte

  • With fixed cable
  • Waterproof (IP 67)


ISM version: With automatic sensor recognition and storage of calibration history. Calibration data and probe ID are stored in the sensor and transmitted automatically to the measuring device
Product Cable length Temperature sensor Type Purchase unit Price per unit
9041509 10 m NTC 30 kOhm InLab® Expert Go-ISM 1 Stück
Price is loading...
9041515 5 m NTC 30 kOhm InLab® Expert Go-ISM 1 Stück
Price is loading...
6233316 1.8 m Without InLab® Expert Go 1 Stück
Price is loading...
7626196 1.8 m NTC 30 kOhm InLab® Expert Go-ISM 1 Stück
Price is loading...
Cable length: 5 m
Connection plug: BNC/RCA
Diaphragm: Hole
Electrolyte: XEROLYT® polymer
Max. pH value: 14
Max. temperature: 100 °C
Min. pH value: 0
Min. temperature: 0 °C
Package size: 1 Stück
Shaft length: 120 mm
Shaft Ø: 12 mm
Temperature: 0 ... 100 °C
Temperature sensor: NTC 30 kOhm
Type: InLab® Expert Go-ISM
pH range: 0 ... 14
Packaging type: -
Alternative products
pH electrode InLab Expert Pro body
Mettler-Toledo
pH electrode InLab® Expert Pro

pH electrode with chemically resistant PEEK shaft and open junction for general applications in the laboratory and outdoors.ARGENTHAL™ reference system with silver ion trapSolid XEROLYT® reference electrolyteWith integrated temperature probe and fixed cableISM version: With automatic sensor recognition and storage of calibration history. Calibration data and probe ID are stored in the sensor and transmitted automatically to the measuring device

Quantity per PU: 1 Stück
pH electrode InLab Expert body
Mettler-Toledo
pH electrode InLab® Expert

pH electrode with chemically resistant PEEK shaft and open junction for general applications in the laboratory and outdoors.ARGENTHAL™ reference system with silver ion trapSolid XEROLYT® reference electrolytePlease order compatible cable separately.

Quantity per PU: 1 Stück
[LLG] pH electrode InLab® Expert DIN | Type: InLab® Expert DIN
Mettler-Toledo
pH electrode InLab® Expert DIN

pH electrode with chemically resistant PEEK shaft and open junction for general applications in the laboratory and outdoors.ARGENTHAL™ reference system with silver ion trapSolid XEROLYT® reference electrolyteWith integrated temperature probe and fixed cableConnector: DIN 19262 / 4 mm

Product number: 9041503
Quantity per PU: 1 Stück
Accessories
Technical Buffer pH 2.00 pack of 30
Mettler-Toledo
Buffer solutions
ghs07 WARNING
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.
  • P302+P352: IF ON SKIN: Wash with plenty of water/
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Sealed sachets in boxes as indicated. For single use only. Packaging ensures that buffer solution is always fresh, has not been used before and is not contaminated.

Product number: 7661134
Quantity per PU: 30 Stück
pH value (25°C)
pH buffer solutions,technical,pH 5.00
Mettler-Toledo
pH buffer solutions

Technical, NIST/DIN and certified buffer solutions for calibrating pH electrodes.Tolerance: ± 0.02 pH

Product number: 4679281
Quantity per PU: 1 Stück
Content
Package size
Product specific notes
pH value (25°C)
[LLG] Regeneration solution for pH electrodes
Mettler-Toledo
Regeneration solution for pH electrodes
Dual
Use
ghs05 Danger
  • H314: Causes severe skin burns and eye damage.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
  • P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Regeneration solution for reactivating pH electrodes. Treatment time approx. 1 minute.

Product number: 6070389
Quantity per PU: 1 Stück
[LLG] Storage solution InLab® | Type: InLab®
Mettler-Toledo
Storage solution InLab®

Storage solution for ph and ORP electrodes.

Product number: 6264638
Quantity per PU: 1 Stück
Cleaning sol. pepsin-HCl with a
Mettler-Toledo
Cleaning solution for electrodes
ghs05 Danger
  • H314: Causes severe skin burns and eye damage.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
  • P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Pepsin HCl solution for cleaning and maintenance of ph electrodes. Removes protein deposits from diaphragms, helping to maintain electrode performance.

Product number: 6310626
Quantity per PU: 6 Stück
Content
No. of packages
Package size