Filter products
Spectrophotometers
PS. Conical base. Sample cups for use in autoanalysers.
LLG-uniSPEC 1 UV/VIS spectrophotometer is the ideal device for various routine laboratory applications including quality control, basic research and education. This high quality, accurate and cost-efficient unit is equipped with a large LCD display that shows standard curves and other test results.LLG-uniSPEC 1 enables without software the measuring of absorption, transmission as well as concentration, and factor determination via standard curves. It can save 200 groups of data and display wavelength, absorbance and transmittance.Optional software based on Windows 10 expand the application to kinetics, spectrum scanning and multi-wavelength measurements.Single beam system, grid with 1200 lines/mmSilicon photodiode detectorStand-alone unit with large 2.5” LCD DisplayOptional software for Windows 10Automatic wavelength settingEasy creation of standard curves for concentration determinationTungsten lamp and deuterium lamp reduce stray light which ensure high photometric accuracyUSB and parallel port4 position cell holder (10 mm) includedAdditional cell holders optionally availableLarge storage capacity of up to 200 groups of test resultsWavelength resolution 0.1 nmScope of supply: Spectrophotometer, dust cover, manual, 4 glass cuvettes, 2 quartz cuvettes
High-quality and cost-efficient UV/VIS spectrophotometer for pharmaceutical, biochemical, and clinical lab applications. Suitable for different measurement types such as kinetics, wavelength scans, quantitative analysis, multi-wavelength, and DNA/Protein analysis. LLG-uniSPEC 2 is ideal for standard routine measurements.The device can store and save 200 calibration curves. A pre-adjusted lamp design allows a fast and easy lamp replacement. Both lamps can be individually turned on/off to extend the durability. The device can be used either as stand-alone unit or can be operated via a PC by using the supplied software.Single beam system, grid with 1200 lines/mmSilicon photodiode detectorParallel port for printer outputUSB port4 position cell holder (10 mm) includedAdditional cell holders optionally availableLCD displayDeuterium and tungsten lampAutomatic wavelength adjustmentWavelength resolution 0.1 nmScope of supply: Spectrophotometer, software for connection to PC, 4 glass cells, 2 quartz cells, protective cover
High-quality and cost-efficient UV/VIS spectrophotometer for pharmaceutical, biochemical, and clinical lab applications. Suitable for different measurement types such as kinetics, wavelength scans, quantitative analysis, multi-wavelength, and DNA/Protein analysis. LLG-uniSPEC 4 is ideal for complex measurements e.g. required for quality controls.LLG-uniSPEC 4 features a small band width and a high wavelength accuracy. The device can store and save 200 calibration curves. A pre-adjusted lamp design allows a fast and easy lamp replacement. Both lamps can be individually turned on/off to extend the durability. The device can be used either as stand-alone unit or can be operated via a PC by using the supplied software.Single beam system, grid with 1200 lines/mmSilicon photodiode detectorParallel port for printer outputUSB port4 position cell holder (10 mm) includedAdditional cell holders optionally availableLCD displayDeuterium and tungsten lampAutomatic wavelength adjustmentScope of supply: Spectrophotometer, software for connection to PC, 4 glass cells, 2 quartz cells, protective cover
5+1 cuvette changer SZ 2100 controllable through UviLine
Cuvette holder SZ 2140 single 10mm, thermostatable
Hollow cathode Ca + Mg Ø 51 mm 2 Inch multi element lamp
Hollow cathode lamp Nb
Sipper SZ 2150 incl. quartz-flow cuvette
Software for LLG-uniSPEC 1 and LLG-uniSPEC 2 Windows 10 compatible
Cuvette holder 4 positions
Microplate spectrophotometer with linear and orbital shaking mechanism for versatile measurements of microplate-based assays.Suitable for 6 to 384 well microplatesIncubation of microplates up to 50 °CINNO-X software for data evaluationUSB and RS232 interfaceMonochromator-based UV/Vis absorbanceLuminescence and filter-based fluorescence detection for TRF assaysSuitable for spectral scanning, endpoint measurements, kinetic measurements, and scanning of well areasWavelength range: 200 to 999 nm (absorbance), 190 to 720 nm (luminescence), 350 to 700 nm (fluorescence)Microvolume measurements for quantification of nucleic acids possible with nano volume plate. Please order separately.YFP fluorescence filter (481 nm EX) and TRITC fluorescence filter (543 nm EX) are included in the scope of supply. Further fluorescence filters available on request.
Plate for holding a 24-well microtitre plate with 2 µl sample volume. Suitable for nucleic acid quantification up to 2 ng/µl dsDNA. With slot for a 2.5 ml cuvette with 0.5 mm path length.
Single-parameter photometer for analysing various parameters in water treatment. The innovative optics achieves fast, high-precision measurements. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable. Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsAbsorbance measurement possibleProgramming option for one customised methodOption to customise methods list based on reagent typeNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupMethods: M100, M101, M103, M110, M112, M80, M120, M122, M300, M301, M330, M331Scope of supply: 3 x 24 mm vials with lid, 3 x stirring rods, syringe, cleaning brush, screwdriver, USB-C to USB-A cable, instruction manual, reagents, 2 x AA batteries
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.5.5" colour HD touch-displayAuto-calibration functionIntelligent OTZ (One-Time-Zero) functionCan be used with 1 ml, 16 mm and 24 mm cuvettesData management with free software (LabCOM)/app in free cloud including individual accounts and reporting systemPlease order reagents separately.More than 140 different parameter methods (paid activation required)Scope of supply: Multitest Photometer PrimeLab 2.0, 1 x 24 mm cuvette adapter
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.5.5" colour HD touch-displayAuto-calibration functionIntelligent OTZ (One-Time-Zero) functionCan be used with 1 ml, 16 mm and 24 mm cuvettesData management with free software (LabCOM)/app in free cloud including individual accounts and reporting systemPlease order reagents separately.More than 140 different parameter methods (paid activation required)Scope of supply: Multitest Photometer PrimeLab 2.0, carrying case, 4 x 24 mm/10 ml glass cuvettes with lid, light-shield, 24 mm cuvette adapter, stirring rod, 10 ml plastic syringe, cleaning brush, battery-charger with USB-cable (type C)
CLP-Info
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P331: Do NOT induce vomiting.
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.5.5" colour HD touch-displayAuto-calibration functionIntelligent OTZ (One-Time-Zero) functionCan be used with 1 ml, 16 mm and 24 mm cuvettesData management with free software (LabCOM)/app in free cloud including individual accounts and reporting systemPlease order reagents separately.More than 140 different parameter methodsTurbidity (NTU)/PTSA/fluorescein is not activatedScope of supply: Multitest Photometer PrimeLab 2.0, carrying case, 10 x 24 mm/10 ml glass cuvettes with lid, light-shield, 16 and 24 mm cuvette adapters, stirring rod, 10 ml plastic syringe, cleaning brush, battery-charger with USB-cable (type C), 20 ml luer lock syringe, filter adapter, 2 cans with 50 filter papers, 100 ml can with lid
CLP-Info
- H226: Flammable liquid and vapour.
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P233: Keep container tightly closed.
- P234: Keep only in original packaging.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Photometer for the analysis of determined parameters in drinking, industrial and waste water. Different models are available for common analyses as well as for special applications.Ergonomic, waterproof designAccurate, reproducible measurement resultsUser calibration and single point calibrationMeasurement results are displayed directly in ABS or %TZero value remains valid for all tests with the same sample thanks to the one-time zero (OTZ) functionAutomatic storage of measured values with time and date stamp and optional data transfer (IRiM module)Bluetooth® interfaceScroll memoryAutomatic shutdownAdjustment function displayScope of supply: Photometer, carrying case, reagents for 100 tests, cuvettes, batteries, standard accessories
PE lids for test tubes pack of 1000
Combination of spectrophotometer TR 500 and portable docking station for precise and repeatable measurements of liquids, gels and powders. The precisely fitting docking station was specially developed for the TR 500 so that ambient lighting can not enter the sample. Different glass cells offer a wide range of applications. With their robust shape, the devices are ideal for use in every laboratory.CMOS sensor (256 picture elements, double array)Intuitive 3.5 inch TFT color LCD (capacitive), symbol-basedExternal memory with 2000 standards and 20000 samplesFree PC-based OnShade software which allows graphs and statistical process controlOperation languages: English, French, German, Spanish, Portuguese, ChineseMeasurements are easy-to-read through the angled viewing windowIntegrated cover prevents the effects of extraneous lightScope of supply: Spectrophotometer TR 500, complete TR 500 accessories, sample cover, white background plate, 3 x optical glass cells (10, 20, 30 mm)