Filter products
Universal, Heating and Drying incubators
Expansion rack 023 VD/L E3 st.steel
Expansion rack 056 VD/L E3 st.steel
Expansion racks - stainless steel
Expansion racks Aluminum
Expansion racks-stainless steel incl. calibration
Expansion racks-stainless steel incl. calibration
Expansion racks-stainless steel incl. calibration
Access port with silicone plug - 10mm right
Feed-through 30 mm, left with silicone stopper for FD series
Feedthrough 50mm, left with silicone stopper
Feedthrough 50mm, right with silicone stopper
HEPA air filter at the Fresh air supply from the device Filter class H14 (according to EN1822-1: 2009
Safer than disinfection, hot-air sterilisation of containers and instruments.The safety feature for this hot air steriliser: Setpoint Wait. This means that the programme for sterilisation only starts when the set temperature has been reached. This feature can also be used with freely positionable Pt100 temperature sensors. Here the sterilisation time only begins when the set temperature has been reached at all measurement points, and reliable sterilisation is guaranteed at all times.Textured stainless steel housing, rear of zinc-plated steel, intuitively operated TwinDISPLAY(TFT colour display) with touchscreenYou can find a detailed description of the "TwinDISPLAY" model at www.memmert.comAvailable parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), programme time, relative humidity, time zones, summertime/wintertimeTwo Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an errorAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB portControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID functionDisplaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online loggingMultiple overtemperature protection: Electronic temperature monitoring TWW/TWB and mechanical temperature limiter TB acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over/undertemperature alarm
Insert grille - Alluminium
Interface converter - cable set RS 422 and interface converter RS 232 / RS 422
Interface converter - cable set RS 422 and interface converter RS 422 / Ethernet
Interface RS 422, accessories - extension cable RS 422 (50 m) between interface converter and device or plug-in distributor RS 232 / RS 422
RS 422 cable set and interface converter RS 422 / USB for connection to plug-in distributor 10-fold or for connection to 1 device
For daily laboratory use. Models with flap door or lift door available, for temperatures from 1100 °C to 1400 °C. Equipped with programmable controllers B 510 (with touch panel, 5 programmes with 4 segments each), or C 550 (with touch panel, 10 programmes with 20 segments each), L 1/12 with controller R 7 (continuous operation).Dual shell housing made of textured stainless steel sheets for low external temperatures and high stabilityAdjustable air inlet integrated in doorExhaust air outlet in rear wall of furnaceSolid state relays provide low-noise operationStandard connector 230 V 1/N/PE 50/60 Hz24 and 40 l with 400 V 3/N/PE 50/60 HzOptional:Chimney, chimney with fan or catalytic converterOver-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and loadProtective gas connection to purge with non-flammable protective or reaction gases (not available in combination with chimney, chimney with fan or catalytic converter)Manual or automatic gas supply systemProcess control and documentation via VCD software package for monitoring, documentation and controlCeramic heating plates with integrated heating wire, splash and exhaust protected, easy to replaceHeating from two sides (three sides for interior volumes of 24, 40 and 60 l)The hot side of the lift door is facing away from the operator
Multi Management Software APT-COM Version 4, GLP Edition for recording, controlling and monitoring