Filter products
Test incubators
The climate chamber generation with the unique ControlCOCKPIT for a quick and intuitive operation. Unparalleled temperature and humidity homogeneity for long-term stable ambient conditions.PID microprocessor control with integrated auto-diagnostic systemInterior stainless steel 1.4301 (ASTM 304), deep-drawnStructured stainless steel housing, rear of zinc-plated steelHigh-Operation and adjustment of all parameters directly at the ControlCOCKPIT temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standardsInternal data logger with a storage capacity of at least 10 yearsGerman, English, French, Spanish language settings available on the ControlCOCKPITDigital backwards counter with target time setting adjustable between 1 minute and 99 daysThe SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamberAdjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT, for example relative humidityMoisture tight standard entry port, at the back, 40 mm inner diameter, can be closed by silicone stopperTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysAvailable parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), programme time, relative humidity, time zones, summertime/wintertimeTwo Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an errorAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB portControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID functionDisplaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online loggingMultiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2 and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN/MAX values for over/undertemperature alarm
Thanks to unbeatable energy efficiency and low-maintenance operation, the HPPeco constant climate chambers are perfectly suited for stability tests, environmental testing and materials testing. The high precision temperature control as well as the active humidification and dehumidification were particularly adapted to the ICH guidelines, option Q1A, for stability tests.LED light module for sizes 110 to 750 (as an option): dimmable LED light in three alternative colour temperatures (cold white light, warm white light or cold white and warm white light, dimmable in steps of 1 %)Heating and cooling seamlessly with one system thanks to Peltier technology. Almost vibration-free and extremely quietTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysYou can find a detailed description of the "TwinDISPLAY" model at www.memmert.com
Constant climate chambers for long-term tests and accelerated stability tests of pharmaceutical products according to the ICH guideline Q1A. Particularly energy-efficient and low-noise thanks to Peltier technology with patented heat dissipation.Homogeneous climate even with full loadElectronically controlled APT.line™ preheating chamber technologyTemperatures up to 28 °C below ambient temperature possibleInner chamber made completely of stainless steel2 stainless steel grids incl. shelf supportAccess port with silicone plug Ø 30 mm, left sideUnit self-test for comprehensive status analysisLCD display for indication of temperature, humidity, alarms and additional informationInternal data logger with USB interfaceIndependent water supply via canisters
Environmental chambers are ideal for material testing under dynamic conditions. The standard rapid alternation speeds of approx. 5 K/min enable standard-compliant testing.Homogeneous climate conditions thanks to APT.line™ preheating chamber technologyTouchscreen controller with time-segment and real-time programmingInternal data logger, measured values can be read out via USBProgrammable condensation protectionTroubleshooting system with visual and acoustic alarmsHeated viewing window with LED interior lightingBINDER Multi Management Software APT-COM™ Basic EditionClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmEthernet interfaceAdjustable ramp functionIntegrated chart recorderDoor heatingInner chamber made of stainless steel1 stainless steel rackHumidity regulation with capacitive humidity sensor and responsive steam humidificationAutomatic water and wastewater managementIntegrated 20 l water storage tank4 zero-voltage relay contactsCFC-free refrigerant R-452AModels with 480 V nominal voltage are equipped with a voltage and frequency converter.
Environmental chambers are ideal for material testing under dynamic conditions. The standard rapid alternation speeds of approx. 5 K/min enable standard-compliant testing.Homogeneous climate conditions thanks to APT.line™ preheating chamber technologyTouchscreen controller with time-segment and real-time programmingInternal data logger, measured values can be read out via USBProgrammable condensation protectionTroubleshooting system with visual and acoustic alarmsHeated viewing window with LED interior lightingBINDER Multi Management Software APT-COM™ Basic EditionClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmEthernet interfaceAdjustable ramp functionIntegrated chart recorderDoor heatingInner chamber made of stainless steel1 stainless steel rackHumidity regulation with capacitive humidity sensor and responsive steam humidificationAutomatic water and wastewater managementIntegrated 20 l water storage tank4 zero-voltage relay contactsCFC-free refrigerant R-452A and R-23Models with 480 V nominal voltage are equipped with a voltage and frequency converter.
The units are suitable for apptications in the pharmaceutical or life science sector. Optimal incubation conditions due to temperature, light, and humidity control.Stainless steel interior and shelvesMassive doorDirected horizontal airflow systemAdjustable defrost timerOver- and under-temperature protectionRefrigerant R-513AHeight-adjustable, vertical light modules (optional)Programmable light cycles: on/off cycles for every day of the week, dawn/dusk simulationsAccess port Ø 54 mm
The Memmert humidity chamber HCP - This climate chamber offers a full range of comfort, reliability and safety. This humidity chamber is ideally suited for environmental testing, environmental simulation, accelerated service life tests and 85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78.The active humidity control is the guarantee for ideal homogeneity of temperature and humidity as well as for short recovery times after opening the door. In combination with heating on all six sides, including heated inner glass door, it also minimises vaporisation in the interior and thus the risk of condensed water dripping onto the test object. An aluminium thermal conductive layer supports optimum temperature distribution and serves as a heat accumulator in case of a temporary power failure.Model variant TwinDISPLAY: ControlCOCKPIT with two colour displaysYou can find a detailed description of the "TwinDISPLAY" model at www.memmert.com
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars.
Shelves made of stainless steel, perforated.If you are ordering replacement shelves, please provide the serial number prior to ordering, since it might be necessary to order other shelves with different dimensions.
Light module cold white 6.500 K: LED strips arranged on the side walls of the interior, 10 for model 110; 14 for models 260, 410 and 750; programme controlled dimming from 0 to 100 % (in 1 % steps); ramp programming in combination with temperature and humidityLight module cold white 6.500 K + warm white 2.700 K: LED light strips - 10 strips for model 110; 14 strips for model 260, 410 and 750 (5 resp. 7 alternating cold white light strips and 5 resp. 7 warm white light strips); on the side walls of the interior, programme controlled dimming from 0 to 100 % (in 1 % steps); ramp programming in combination with temperature and humidity
The cooled incubators with the unique ControlCOCKPIT for a quick and intuitive operation. Ideal at temperatures around zero and below. For rapid and precise alternation between heating up and cooling down times in ramp operation. Extraordinarily quiet.Standard equipment :PID microprocessor control with integrated auto-diagnostic systemInterior stainless steel, material 1.4301 (ASTM 304) very stable and easy to cleanStructured stainless steel housing, scratch-resistant, robust and durable; rear of zinc-plated steel (all sizes mounted on lockable castors)High-temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standardsInternal data logger with a storage capacity of at least 10 yearsGerman, English, French, Spanish, Polish, Czech, Hungarian language settings available on the ControlCOCKPITDigital backwards counter with target time setting adjustable between 1 minute and 99 daysThe SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamber.Adjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPITTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysYou can find a detailed description of the "TwinDISPLAY" model at www.memmert.com
Drain fitting G 1 ½ Type V
FDA integration per additional device (up to max. 15 pieces) into an already acquired FDA license. (E05019) / ***Serial number required***
Smart card empty preformats (32 kB MEMoryCard XL for max. 40 ramps)
Write-/readdevice for PC-interface (Chipdrive-Micro)
Alarm function for overtemperature switchable audible alarm, with adjustable limit value at the temperature selector
Premium module: The premium module comprises the inert gas inlet (only sizes 49/101), extra connectors for thermoshelves, one for VO29, two for VO49/VO101, an additional thermoshelf for model size 49/101.Vacuum pump module: Without pump with antivibration metal plate at the bottom to accommodate the vacuum pump, including full-sight glass door, socket, signal cable and connecting hose to the vacuum oven.Chemical-resistant vacuum pump: With 4x diaphragm, pump capacity: approx. 50 Nl/min = 3.0 m/h³, automatic purge control, with signal cable (3 m) to control the rotation speed and vacuum connecting hose (3 m).
The climate chamber generation with the unique ControlCOCKPIT for a quick and intuitive operation. Unparalleled temperature and humidity homogeneity for long-term stable ambient conditions.PID microprocessor control with integrated auto-diagnostic systemInterior stainless steel 1.4301 (ASTM 304), deep-drawnStructured stainless steel housing, rear of zinc-plated steelHigh-Operation and adjustment of all parameters directly at the ControlCOCKPIT temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standardsInternal data logger with a storage capacity of at least 10 yearsGerman, English, French, Spanish language settings available on the ControlCOCKPITDigital backwards counter with target time setting adjustable between 1 minute and 99 daysThe SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamberAdjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT, for example relative humidityMoisture tight standard entry port, at the back, 40 mm inner diameter, can be closed by silicone stopperTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysAvailable parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), programme time, relative humidity, time zones, summertime/wintertimeTwo Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an errorAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB portControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID functionDisplaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online loggingMultiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2 and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN/MAX values for over/undertemperature alarmSpecially designed for testing pharmaceutical products according to ICH, Q1A and Q1B, option 2, and similar global standards for stability tests of cosmetics and food.
Commissioning devices on APT-COM port and configuration of a device to the software, without on-site cabling
Spacer bolts 30 mm Fan shaft cover