Filter products
Burners
For operation with gas cartridges CV 300 Plus (Cat.-No.: 6.243 905) or CV 470 Plus (Cat.-No.: 9.018 512).
Bunsen burner with needle valve and pilot flame DIN (NG-2411 BO0031).
With air regulator and needle gas valve. Adjustable nozzle.
DIN 30665. Air regulation, spar flame.
DIN 30665. Air regulation.
CLP-Info
- H220: Extremely flammable gas.
- P102: Keep out of reach of children.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P377: Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
- P381: In case of leakage, eliminate all ignition sources.
- P403: Store in a well-ventilated place.
With needle gas valve and air regulator.Only for the gas cartridge 9.018 364.
Electrothermal's Electric Bunsen combines the advantages of a regular gas burner with the clean, easy operation of their electric mantles. The Electric Bunsen is ideal for non-contact heating of test tubes, crucibles, small flasks, and beakers, regardless of their shape.Conical shaped heating element directs radiant heat to the top cavityTop cowl deflects heat away from your handAir circulation from the vented housing keeps the base cool enough to hold during operationCorrosion-resistantWith controller CN-200
For precise and time-controlled flaming of different kinds of inoculating loops. Minimization of gas consumption, the life of the inoculating loops is significantly increased. The inoculating loop is placed into the carousel after use and is sterilized immediately after turning the holder in flaming position. Sterilization time infinitely adjustable. Designed for continuous work-flow with sample series in the Laminar Flow. Comfortable manual rotation, fully automated flaming process. For use with Safety Bunsen Burners schuett phoenix II standard and accu. Sterilization time: 3 to 5 s (adjustable from 1 s to 120 min). For 6 inoculating loop holders.
Mobile device for scarfing and flame-sterilising. With piezoelectric-ignition and gas supply control to create a soft or sharp flame. Infinite adjustment of the flame. Highest operational safety. In short-term use, the flame is activated as long as the push button is pressed. For continuous operation with lock key.schuett easyflame to use with propane/butane gas1. Suitable with gas cartridges with 7/16" connection thread, e.g. CG 1750, Express 444, AT 2000.2. Adapters for CV 360 or CP 250 gas cartridges optional.
Mobile device for scarfing and flame-sterilising. With piezoelectric-ignition and gas supply control to create a soft or sharp flame. Infinite adjustment of the flame. Highest operational safety. In short-term use, the flame is activated as long as the push button is pressed. For continuous operation with lock key.schuett easyflameplus for connecting natural gas and propane / butane gas with gas safety hoses1. Natural gas hose for central gas supply for easy plugging the device (hose barb included)2. Propane / butane gas hose with fitting (1/4 "-left-hand thread) for the use of gas cartridge adapters or gas cylinders with pressure reducer. Matching adapters C 206 and CV 300/470 (already equipped with gas safety hose, 0.5m and reducer). Gas safety tubing in other lengths on request.
Flints 3 x 20 mm for gas lighter 9.018 801
With heart screw. Thread M8.
Laboratory heating device for the safe, rapid heating of large samples. Can be used anywhere, even where standard burners with an exposed flame cannot be used.Heats up quickly, constant heatingNo open flames, no soot, odourlessIntegral continuous electronic power adjustment between 0% and 100%Casing safe to touch even when hotBuilt-in casing handles for safe transportInert ceramic, long-life heating elementBuilt-in overheat monitorProtection of electrical components against spilled liquidsAdditional side safety shield on burner elementIncludes four-arm support for flat bottom containers. By using an accessory bracket the burner can be mounted on a tripod
The PowerCube is suitable for all rapid, non-contact heating activities in laboratories, industry and education. Reagent bottles, flasks or dishes, depending on their size, can be placed directly on the support trivet over the heating element or attached to a stand mounting.Advantages:Particularly safe as no open flame is usedStable thanks to practical cube shape. The casing itself only gets slightly hot in useAccelerated heating-up rate in comparison with other electrical heating devicesHeating element sealed in ceramic, therefore insensitive to external influences (spillages)Low operational cost due to the long life heating element and low power consumption of only 200 W, in spite of high temperatures of 700°C
Sterilisation with light. Sterilisation of inoculating loops, tweezers and small instruments within seconds.Sturdy and maintenance-freeNo gas, no open flame - Works with standard electrical powerIntuitive, easy to useInstant, ready-to-use, no warm-up time, no waitingSterilization temperature: 900 to 1300°CTouch-free START, with IR- sensor and adjustable timer (5 to 7 seconds)For use in Laminar Flow CabinetsIdeal for mobile operation in the fieldThe schuett solaris is the perfect solution if an open flame should be avoided or gas cartridges etc. are not available. Used with standard electrical power. Reaches the safe working temperature of 900 to 1300°C within a split second. No excess heat, no energy consumption between work cycles. START is generated by an infra-red sensor, which allows for efficient one-handed operation. Pathogenic material is kept inside the sterilization chamber. No spreading, no splashing. Working angle adjustment (4-steps).Scope of supply: schuett solaris inoculation loop sterilizer, 2 x quartz glass tubes, 1 x inoculation loop holder with inoculation loop (sample)
With stopcock. Air regulation, max. 1300°C. An anti-slip rubber coating under the base ensures absolute stability.
For metallic gas cartridges according to DIN EN 417:2012. Outside thread M 10 x 1.
Quartz tube with bottom.
For sterilising, heating, flame sterilising. For use in every microbiological laboratory or in safety cabinets. Housing made of stainless steel and safety glass. UV- and solvent resistant. For case of cleaning and flame-sterilising. Suitable for use with natural gas (central gas) or butane/propane gas (gas cartridges).Modern Bunsen burner with state-of-the-art safety features plus outstanding quality characteristics:Controlled burning time 1 sec to 120 min (selectable)Automatic safety shut-off (selectable)Overheating protection/burner control by sensorsPrecise economic flame regulation (stable flame in strong air current)Flame and ignition monitoring"Push-and-Twist" bayonet fixture for burner head, no tools needed for cleaningTilting right or leftSafety standard acc. to DIN 30665 part 1, DIN-DVGWschuett phoenix II eco: with LED control lamp and foot-switch. Start flame by foot-switch or button (On/Off). Best suited for use in microbiological safety cabinets.
Maximum temperature 1300°C, with needle valve, thermo safety element (bimetallic flame sensor with magnetic lock), air regulator and pilot light. Nickel-plated brass and steel. An anti-slip rubber coating under the base ensures absolute stability.