Filter products
Air sampling and analysis
Fast measurement with one hand: The Dräger-Tube pump accuro® allows you to use the established Dräger-Tubes® to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.Gas pump Dräger accuro® set consisting of:Dräger-Tubes® pump accuro®, ready bag, with tube opener and spare part set
Membrane filters specially designed for air and virus collection, 25mm pack of 50
Pollution monitors for collecting gases and vapours in the ambient atmosphere. Ideal for detecting pollutant concentration in the workplace. The 3M™ Pollution monitor is equipped with a single charcoal adsorbent wafer that binds pollutants in the air by means of diffusion.Suitable for personal and area monitoringEasy to use: the pollution monitor can simply be clipped onto clothingSmall and lightweight
The gas analysers are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside. Easy and intuitive operation via touchscreen, even by untrained personnelCreate your own methodAvailable method parameters: scales, measurement procedures, limit values, comment and much moreSelectable measurement methods: single or continuousSeveral single measurement procedures: manual, automatic, min/max detectionShortcut keys for most important functionsShort measurement period, high accuracy even with small sample volumeValidation possibleCompliance with global standards such as GMP/GLP and 21 CFR Part 11Documentation of all measured values of the last 999 measurementsIntegrated interfaces, flexible data export (USB, Ethernet, RS-232)Compact design in robust cast aluminum housingBuilt-in air pressure sensorIntegrated flow rate monitoringWith the electrochemical oxygen cell the instrument measures the oxygen concentration within the range of 0.5 and 35 vol % and with an accuracy of ±0.2 vol %.
The gas analysers are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside. Easy and intuitive operation via touchscreen, even by untrained personnelCreate your own methodAvailable method parameters: scales, measurement procedures, limit values, comment and much moreSelectable measurement methods: single or continuousSeveral single measurement procedures: manual, automatic, min/max detectionShortcut keys for most important functionsShort measurement period, high accuracy even with small sample volumeValidation possibleCompliance with global standards such as GMP/GLP and 21 CFR Part 11Documentation of all measured values of the last 999 measurementsIntegrated interfaces, flexible data export (USB, Ethernet, RS-232)Compact design in robust cast aluminum housingBuilt-in air pressure sensorIntegrated flow rate monitoringWith the electrochemical oxygen cell the instrument measures the oxygen concentration within the range of 0.5 and 35 vol % and with an accuracy of ±0.2 vol %. The non-dispersive infrared sensor measures carbon dioxide within the range of 0 and 100 vol % and with an accuracy of ±0.5 vol %.
The gas analysers are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside. Easy and intuitive operation via touchscreen, even by untrained personnelCreate your own methodAvailable method parameters: scales, measurement procedures, limit values, comment and much moreSelectable measurement methods: single or continuousSeveral single measurement procedures: manual, automatic, min/max detectionShortcut keys for most important functionsShort measurement period, high accuracy even with small sample volumeValidation possibleCompliance with global standards such as GMP/GLP and 21 CFR Part 11Documentation of all measured values of the last 999 measurementsIntegrated interfaces, flexible data export (USB, Ethernet, RS-232)Compact design in robust cast aluminum housingBuilt-in air pressure sensorIntegrated flow rate monitoringWith the zirconium dioxide sensor (ZrO2) the instrument measures the oxygen concentration over the entire measurement range between 0 and 100 vol % and with an accuracy of ±0.02 vol % abs.
The gas analysers are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside. Easy and intuitive operation via touchscreen, even by untrained personnelCreate your own methodAvailable method parameters: scales, measurement procedures, limit values, comment and much moreSelectable measurement methods: single or continuousSeveral single measurement procedures: manual, automatic, min/max detectionShortcut keys for most important functionsShort measurement period, high accuracy even with small sample volumeValidation possibleCompliance with global standards such as GMP/GLP and 21 CFR Part 11Documentation of all measured values of the last 999 measurementsIntegrated interfaces, flexible data export (USB, Ethernet, RS-232)Compact design in robust cast aluminum housingBuilt-in air pressure sensorIntegrated flow rate monitoringWith the zirconium dioxide sensor (ZrO2) the instrument measures the oxygen concentration over the entire measurement range between 0 and 100 vol % and with an accuracy of ±0.02 vol % abs. The non-dispersive infrared sensor measures carbon dioxide within the range of 0 and 100 vol % and with an accuracy of ±0.5 vol %.
Made from 5 mil (125 µm) FEP fluoropolymer film, these flexible, sturdy bags are heat sealed on all four sides for complete chemical resistance and leak-proof operation. They are inert to most chemicals and have low permeability which limits sample loss. These FEP bags are easy to use. They can be stored for an unlimited period prior to use. Applications include gas sample analysis, extracting air samples from smokestack exhaust systems, monitoring air quality or calibrating instruments in the field. The bags are individually packaged.Chemically resistantFlexibleWill not contaminate sampleWith a nickel-plated, brass on/off valve that accepts 6.4 mm I.D. flexible tubing.
Reusable bags made of 2 mil (50 µm) PVDF fluoropolymer film, Chemware® Gas Bags offer an economical alternative for analysis of noncorrosive gases. Durable, heat-sealed seams ensure leak-proof operation. Applications include sampling carbon monoxide, sulfur dioxide, hydrogen sulfide, radon and mercaptan. The bags are individually packaged. When used for liquid samples, bags should be supported with a tray. Custom sizes and configurations available on request.FlexibleWill not contaminate sampleFor use in gas sampling trainsUse for gas or liquid sample containmentWith a nickel-plated, brass on/off valve that accepts 6.4 mm I.D. flexible tubing.
Made from 5 mil (125 µm) FEP fluoropolymer film, these flexible, sturdy bags are heat sealed on all four sides for complete chemical resistance and leak-proof operation. They are inert to most chemicals and have low permeability which limits sample loss. These FEP bags are easy to use. They can be stored for an unlimited period prior to use. Applications include gas sample analysis, extracting air samples from smokestack exhaust systems, monitoring air quality or calibrating instruments in the field. The bags are individually packaged.Chemically resistantFlexibleWill not contaminate sampleWith PTFE/silicone septum in polypropylene housing for use with a hypodermic needle.
Digital probes with intelligent calibration concept. All probe heads can be easily attached to the universal handle.
Mains adapter 100-240 V
Manometer EN837-1 KL 1.6 with factory certificate
Prüfröhrchen Methylacrylat 51/a VE=10 Ätzender, saurer anorganischer fester Stoff, N.A.G UN 3260, 8, III, (E)
Mouthpiece with breath back barricade, pack of 250
NiMH Accu, T4 UN 3496, 9, M11
Perchloroethylene tubes 2/a pack of 10, 2-300ppm
Monitor für organ. Dämpe Typ 3500 (ohne Analyse)
Benzol 0,5-10 ppm (kalibrierter Chip)
Car-adapter-cable for flow-check