Filter products
Turbidity
Imhoff pattern. DIN 12672. Transparent SAN (Styrene acrylonitrile). With screw cap for draining the contents. Temperature-resistant up to max. 85°C.
Acrylic/PP. To hold two Imhoff sedimentation cones. Compact and easy to transport even when fully loaded.
Imhoff pattern. DIN 12672. Graduations and inscriptions in contrasting white enamel. Ring mark at 1000ml.
The microprocessor-based waterproof Infra-Red Turbidity meter TN-100 is easy-to-use and meets all rigor of rugged field applications. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).IP67 Waterproof and Dustproof, easy cleaning and maintenance Automatic Push-Button Calibration (4 points) for unprecedented full-range accuracy Power-saving feature allows over 1200 measurementsLarge Easy-to-Read Display for optimum viewing of measurements with user-friendly message codes for easy troubleshooting Meets Performance Criteria as specified by ISO 7027 (DIN EN 27027) method Scope of supply: Turbidity meter with 4 calibration standards, 3 empty cuvettes, sturdy carrying case, batteries and instruction manual
For determining the depth of visibility and light permeability of water. Sturdy design made of strong, hard-wearing plastic. Lead weight for better lowering. The approx. 15 cm high rod is fitted with an eyelet for fastening the lowering engine. The lowering line is marked in intervals of 100 cm with figures from 1 to 10 and in between additionally with line markings each 50 cm for better reading of the depth of visibility while the disk is being lowered.Lowering line, please order separately.
CLP-Info
- H317: May cause an allergic skin reaction.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P363: Wash contaminated clothing before reuse.
- P501: Dispose of contents/container to
turbidimeter TB 300 IR Infrared LED (no ADR)
USB cable
Imhoff pattern, solid grey PVC. Stable design.
Imhoff pattern, solid grey PVC. Stable design.
For simultaneous injection of coagulant or reagents in six sample beakers.
For flocculation tests of water and waste water.choice of 2- or 6-bank modelsdigital speed displaytwo adjustable speed presetsaccurate and reproducible speedsdiffused base illumination with black backgroundaccepts beakers up to 1000ml.Supplied with rotor blades but without beakers.With BioCote silver based antimicrobial protection.
Transparent, sturdy frame for three 1000 ml Imhoff sedimentation vessels.
For two sedimentation cones made of plastic.
Scale: up to 1000 ml, ring mark: at 1000 ml, subdivision: 0.1 ml (0-2 ml), 0.5 ml (2-10 ml), 1 ml (10-40 ml), 2 ml (20-100 ml), 50 ml (100-1000 ml).
Imhoff pattern, wood.
CLP-Info
- H317: May cause an allergic skin reaction.
- H350: May cause cancer .
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P405: Store locked up.
The portable turbidity meters are characterised by the use of Multipath 90° BLAC® technology. Samples with low and high turbidity can be analyzed entirely nephelometric (Detection angle 90°) with the highest accuracy over the complete measuring range up to 4000 NTU. By eliminating stray light, highly accurate results are achieved for low turbidities down to 0.01 NTU.High performance optics to ensure accuracyElimination of stray light through light absorbing trap (BLAC®)Intuitive colour touch screen with animated guided procedures and straightforward data management, multilingualVisual warning for out-of-tolerance readingsData logger for 250 measurements plus all calibrations, verifications and factory recovery procedures3 different modes: single, signal averaging, fast settlingUSB-C interfaceScope of supply: Instrument, carrying case with plastic insert, T-CAL® calibration and verification standards, silicone oil, sample vials with black lids, cleaning cloth, brush for sample vials, screwdriverWith infra red LED light source (860 nm), acc. to ISO 7027. Incl. Turbidity standards with 5, 20, 800 and 4000 NTU.
CLP-Info
- H317: May cause an allergic skin reaction.
- H350: May cause cancer .
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P405: Store locked up.
The portable turbidity meters are characterised by the use of Multipath 90° BLAC® technology. Samples with low and high turbidity can be analyzed entirely nephelometric (Detection angle 90°) with the highest accuracy over the complete measuring range up to 4000 NTU. By eliminating stray light, highly accurate results are achieved for low turbidities down to 0.01 NTU.High performance optics to ensure accuracyElimination of stray light through light absorbing trap (BLAC®)Intuitive colour touch screen with animated guided procedures and straightforward data management, multilingualVisual warning for out-of-tolerance readingsData logger for 250 measurements plus all calibrations, verifications and factory recovery procedures3 different modes: single, signal averaging, fast settlingUSB-C interfaceScope of supply: Instrument, carrying case with plastic insert, T-CAL® calibration and verification standards, silicone oil, sample vials with black lids, cleaning cloth, brush for sample vials, screwdriverWith white light LED light source, acc. to EPA (pending). Incl. Turbidity standards with 5, 20, 800, 2000 and 4000 NTU.
The turbidity meters Turb® 430 IR acc. to DIN ISO 27027 and Turb® 430 T acc. to US EPA 180.1 meet the requirements of the nephelometric measurement at 90° stray light for drinking water with highest precision, especially in the range < 1 NTU. The measuring range comprises 0-1100 NTU/FNU with automatic measuring range switching and is therefore suitable for water analysis as well as quality control, such as gasoline, cell cultures, as well as in the food and beverage industries.The measurement and automatic 3-point calibration runs self-explanatory and menu-controlled. The calibration takes place via an AMCO Clear® standard set (0.02-10-1000 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata. The quality assurance of the measured results is supported by calibration interval setting with documentation.Scope of supply: Turbidity meter in case with table insert, calibration set 0.02-10.0-1000 NTU, PC software LSdata, accessories
The turbidity meters Turb® 430 IR acc. to DIN ISO 27027 and Turb® 430 T acc. to US EPA 180.1 meet the requirements of the nephelometric measurement at 90° stray light for drinking water with highest precision, especially in the range < 1 NTU. The measuring range comprises 0-1100 NTU/FNU with automatic measuring range switching and is therefore suitable for water analysis as well as quality control, such as gasoline, cell cultures, as well as in the food and beverage industries.The measurement and automatic 3-point calibration runs self-explanatory and menu-controlled. The calibration takes place via an AMCO Clear® standard set (0.02-10-1000 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata. The quality assurance of the measured results is supported by calibration interval setting with documentation.Scope of supply: Turbidity meter with calibration set 0.02-10.0-1000 NTU
Highly accurate turbidity standards composed of suspended microspheres, suitable for Instrument calibration and control of all turbidity meters. Stable, shelf life of 2 years (from Date of Manufacturing). NIST traceable, US EPA approved and tested in compliance with ISO 7027. HDPE bottles of 100 or 500 ml.Non Ratio for Non Ratio Turbidity Measuring instruments will measure the scattered light from the sample at a 90° angle from the incident light (one detector).