Filter products
Photometric analyses (cuvette tests)
NANOCOLOR Lead (without CCl4) Standard test (additionally carbon tetrachloride is necessary) consists of 2 boxes:
NANOCOLOR Manganese standard test measuring range: 0.005 – 3.00 mg/L Mn
NANOCOLOR Methanol 15 tube test measuring range: 0.2-15.0 mg/L MeOH sufficient for 23 determinations
CLP-Info
- H301: Toxic if swallowed.
- H311: Toxic in contact with skin.
- H314: Causes severe skin burns and eye damage.
- H331: Toxic if inhaled.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P405: Store locked up.
NANOCOLOR Molybdenum 40 tube test measuring range: 1.0-40.0 mg/L Mo(VI) 1.6-65.0 mg/L MoO42- sufficient for 20 determinations
CLP-Info
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P264: Wash skin thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P284: [In case of inadequate ventilation] wear respiratory protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P405: Store locked up.
- P501: Dispose of contents/container to thgHazMat.product.entsorgungFachgerecht
NANOCOLOR Nickel 4 tube test measuring range: 0.10-7.00 mg/L Ni2+ 0.02-1.00 mg/L Ni2+ sufficient for 20 determinations
CLP-Info
- H225: Highly flammable liquid and vapour.
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H332: Harmful if inhaled.
- H335: May cause respiratory irritation.
- H350: May cause cancer .
- H400: Very toxic to aquatic life.
- P201: Obtain special instructions before use.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
NANOCOLOR Nickel standard test measuring range: 0.01-10.0 mg/L Ni2+ sufficient for 250 determinations
CLP-Info
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P264: Wash hands thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to regulated waste treatment
NANOCOLOR Nitrat standard test measuring range: 0.9-30.0 mg/L NO3-N 4-140 mg/L NO3- sufficient for 100 determinations
NANOCOLOR Nitrate 50 for examination on Skalar robots Tube test with Barcode pack of 20 tests Concentration sulphuric acid 51-65%
NANOCOLOR Nitrate 8 for examination on Skalar robots Tube test with Barcode pack of 20 tests Concentration sulphuric acid 51-65%
CLP-Info
- H317: May cause an allergic skin reaction.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P272: Contaminated work clothing should not be allowed out of the workplace.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P362+P364: Take off contaminated clothing and wash it before reuse.
- P501: Dispose of contents/container to
NANOCOLOR Nitrate Z standard test measuring range: 0.02-1.0 mg/L NO3-N 0.1-5.0 mg/L NO3- sufficient for 500 determinations
NANOCOLOR Nitrite 2 for examination on Skalar robots Tube test with Barcode pack of 20 tests
NANOCOLOR Nitrite 4 for examination on Skalar robots tube test measuring range: 0.1-4.0 mg/L NO2-N 0.3-13.0 mg/L NO2- sufficient for 20 determinations
NANOCOLOR org. Complexing agents 10 tube test, for screening measuring range: 0.5-10.0 mg/L IBiK sufficient for 10-19 determinations
CLP-Info
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H351: Suspected of causing cancer .
- P201: Obtain special instructions before use.
- P202: Do not handle until all safety precautions have been read and understood.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P264: Wash hands thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301: IF SWALLOWED:
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P405: Store locked up.
- P501: Dispose of contents/container to regulated waste treatment
NANOCOLOR Organic acids 3000 tube test measuring range: 30-3000 mg/L CH3COOH 0.5-50.0 mmol/L CH3COOH sufficient for 20 determinations
NANOCOLOR ortho Phosphate 1 for examnation on Skalar robots Tube test with Barcode sufficient for 20 determinations
CLP-Info
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P264: Wash skin thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to local/regional/national/international regulations
NANOCOLOR ortho Phosphate standard test measuring range: 0.04-6.5 mg/L PO4-P 0.1-20.0 mg/L PO43- sufficient for 500 determinations
NANOCOLOR ortho Phosphate standard test measuring range: 0.2-17 mg/L PO4-P 0.5-50 mg/L PO43- sufficient for 500 determinations
NANOCOLOR ortho- and total Phosphate 5 for exemination on Skalar robots Tube test with Barcode pack of 20 tests
NANOCOLOR ortho-Phosphate 15 for examination on Skalar robots Tube test with Barcode pack of 20 tests
NANOCOLOR Oxygen 12 tube test measuring range: 0.5-12.0 mg/L O2 sufficient for 22 determinations