Filter products
Photometric analyses (cuvette tests)
CLP-Info
- H226: Flammable liquid and vapour.
- H302: Harmful if swallowed.
- H312: Harmful in contact with skin.
- H314: Causes severe skin burns and eye damage.
- H332: Harmful if inhaled.
- H370: Causes damage to organs .
- H410: Very toxic to aquatic life with long lasting effects.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P264: Wash hands thoroughly after handling.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P311: IF exposed or concerned: Call a POISON CENTER/doctor/
- P310: Immediately call a POISON CENTER/doctor/
- P391: Collect spillage.
Aluminium cuvette test measuring range 0.02-0.5 mg/l *
CLP-Info
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H360: May damage fertility or the unborn child .
Ammonia Assay Kit (Rapid), 96 assays (manual) / 960 assays (microplate) / 960 assays (auto-analyser), for the rapid measurement and analysis of ammonia in all samples, including grape juice and wine (and other foods/beverages)
CLP-Info
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P332+P313: If skin irritation occurs: Get medical advice/attention.
Ammonia conditioning powder for seawateranalysis pack with 100 tests
Ammonium buffer solution for complexometry (ammonium chloride/ammonia) pH = 10-11 Titripur®
CLP-Info
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H412: Harmful to aquatic life with long lasting effects.
- P264: Wash thoroughly after handling.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P312: IF SWALLOWED: Call a POISON CENTRE/doctor/ if you feel unwell.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Ammonium Cell Test Method: photometric 0.20 - 8.00 mg/l NH4-N 0.26 - 10.30 mg/l NH4+ Spectroquant®
CLP-Info
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H412: Harmful to aquatic life with long lasting effects.
- P264: Wash skin thoroughly after handling.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P312: IF SWALLOWED: Call a POISON CENTRE/doctor/ if you feel unwell.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Ammonium Cell Test Method: photometric 4.0 - 80.0 mg/l NH4-N 5.2 - 103.0 mg/l NH4+ Spectroquant®
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H361d: Suspected of damaging the unborn child.
- H411: Toxic to aquatic life with long lasting effects.
- EUH031: Contact with acids liberates toxic gas.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P264: Wash face, hands and any exposed skin thoroughly after handling.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P337+P313: If eye irritation persists: Get medical advice/attention.
- P391: Collect spillage.
Ammonium cuvette test measuring range 0.015-2 mg/l NH4-N
CLP-Info
- H225: Highly flammable liquid and vapour.
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H336: May cause drowsiness or dizziness.
- H412: Harmful to aquatic life with long lasting effects.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P312: IF SWALLOWED: Call a POISON CENTRE/doctor/ if you feel unwell.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Ammonium Test Method: photometric 0.010 - 3.00 mg/l NH4-N Spectroquant®
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H311: Toxic in contact with skin.
- H314: Causes severe skin burns and eye damage.
- H373: May cause damage to organs through prolonged or repeated exposure .
- H410: Very toxic to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
AOX Cell Test Method: photometric 0.05 - 2.50 mg/l Spectroquant®
CLP-Info
- EUH210: Safety data sheet available on request.
Aqua-check pack of 100
CLP-Info
- H318: Causes serious eye damage.
- H341: Suspected of causing genetic defects .
- H412: Harmful to aquatic life with long lasting effects.
- P201: Obtain special instructions before use.
- P202: Do not handle until all safety precautions have been read and understood.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to
Ascorbic Acid Assay Kit (L-Ascorbate), 40 assays (manual) / 400 assays (microplate) / 400 assays (auto-analyser), for the analysis of L-ascorbic acid in beverages, meat, flour, dairy and vegetable products
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H319: Causes serious eye irritation.
- H412: Harmful to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
BOD Cell Test Method: photometric 0.5 - 3000 mg/l Spectroquant®
Calibratrion Standard for Photometer HI 701
Cell holder W600, for PFX195
Cellulase Assay Kit (CellG5 Method), 120 / 240 assays (manual), 480 assays (autoanalyser)
CHECKIT COLORPLATE CHLORIDE DPD 0 - 1 MG/L
CHECKIT® Disc DBNPA 0-6.8 ppm
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H311: Toxic in contact with skin.
- H314: Causes severe skin burns and eye damage.
- H373: May cause damage to organs through prolonged or repeated exposure .
- H410: Very toxic to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P312: IF SWALLOWED: Call a POISON CENTRE/doctor/ if you feel unwell.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P314: Get medical advice/attention if you feel unwell.
Chloride Cell Test Method: photometric 5 - 125 mg/l Cl- Spectroquant®
CLP-Info
- H226: Flammable liquid and vapour.
- H301: Toxic if swallowed.
- H311: Toxic in contact with skin.
- H314: Causes severe skin burns and eye damage.
- H331: Toxic if inhaled.
- H370: Causes damage to organs .
- H411: Toxic to aquatic life with long lasting effects.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P311: IF exposed or concerned: Call a POISON CENTER/doctor/
- P391: Collect spillage.
- P403+P233: Store in a well-ventilated place. Keep container tightly closed.
Chloride Cuvette Test/measur. range 1-70 mg/l+70-1000 mg/l *
Chlorine Dioxide Test Method: photometric, DPD 0.020 - 10.00 mg/l ClO2 Spectroquant®