Filter products
Kjeldahl
The temperature-controlled InKjel TC-series devices combine the advantages of infrared and block digestion in one system: Fast Infrared digestion at defined temperatures ensures high sample throughput.In the programmable version InKjel TCP, the user has a choice of 25 freely configurable programs for temperature and digestion time.The high-quality quartz infrared heaters of InKjel TC reach 830 ° C in a minute and achieve uniform heating at all sample positions.
Rapid digestion system with manually adjustable energy control and direct heating of the samples through high-quality quartz radiators (1500W).Quartz infra-red radiators peak at 830°C within 1 min.Particularly uniform heating at all sample positionsAll InKjel systems are fitted completely with multi-level consoles, fume extraction unit, sample rack and glass digestion vessels.Configurations available:6 sample vessels each 250ml12 sample vessels each 100ml12 sample vessels each 250ml4 sample vessels each 500ml4 sample vessels each 750ml
Rapid digestion system with 25 freely configurable programmes for power and digestion time and direct heating of the samples through high-quality quartz radiators (1500W).Quartz infra-red radiators peak at 830°C within 1 min.Particularly uniform heating at all sample positionsAll InKjel systems are fitted completely with multi-level consoles, fume extraction unit, sample rack and glass digestion vessels.Configurations available:6 sample vessels each 250ml12 sample vessels each 100ml12 sample vessels each 250ml4 sample vessels each 500ml4 sample vessels each 750ml
CLP-Info
- H411: Toxic to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P391: Collect spillage.
Kjeldahl catalyst tablets 3,5 G K2S04, 0,4 G CUS04 (box of 1000 pcs.)
Block digestion systems with high-quality corrosion-resistant block housing made of stainless steel. With 16, 24 or 40 sample slots for micro Kjeldahl digestion vessels with a volume of 100 ml. High-efficiency heating and extraction hood with exhaust collector.behr single-knob control for particularly easy and fast programming.Menu navigation in national language.25 freely configurable programs for block temperature and digestion time.Applications can be saved.USB interface.The removable inspection door on the insertion rack enables the progress of the digestion to be observed.Complete systems with digestion vessels, rack and extraction hood.
Block digestion systems with high-quality corrosion-resistant block housing made of stainless steel. With 8, 12 or 20 sample slots for standard Kjeldahl digestion vessels with a volume of 250 ml. High-efficiency heating and extraction hood with exhaust collector.behr single-knob control for particularly easy and fast programming.Menu navigation in national language.25 freely configurable programs for block temperature and digestion time.Applications can be saved.USB interface.The removable inspection door on the insertion rack enables the progress of the digestion to be observed.Complete systems with digestion vessels, rack and extraction hood.
The S-series steam distillers are the ideal complement to the behr Kjeldahl digestion system.Exemplary safety and reliabilityRobust casing of polyurethaneDistillation time approx.. 3 mins. per sampleDetection limit 0.1 mg NRecovery rate >99.5%Reproducibility ± 1%Steam generating capacity adjustable from 10% - 100%Extremely simple, menu-controlled operation of the programmable units via one single operating element (behr one-button operation)Programmable reaction timeSerial interface (RS232)Filling level monitoring for can setPractical quick clamping device
The S-series steam distillers are the ideal complement to the behr Kjeldahl digestion system.Exemplary safety and reliabilityRobust casing of polyurethaneDistillation time approx.. 3 mins. per sampleDetection limit 0.1 mg NRecovery rate >99.5%Reproducibility ± 1%Steam generating capacity adjustable from 10% - 100%Extremely simple, menu-controlled operation of the programmable units via one single operating element (behr one-button operation)Programmable reaction timeSerial interface (RS232)Filling level monitoring for can setPractical quick clamping device
The S-series steam distillers are the ideal complement to the behr Kjeldahl digestion system.Exemplary safety and reliabilityRobust casing of polyurethaneDistillation time approx.. 3 mins. per sampleDetection limit 0.1 mg NRecovery rate >99.5%Reproducibility ± 1%Steam generating capacity adjustable from 10% - 100%Extremely simple, menu-controlled operation of the programmable units via one single operating element (behr one-button operation)Programmable reaction timeSerial interface (RS232)Filling level monitoring for can setPractical quick clamping device
The S-series steam distillers are the ideal complement to the behr Kjeldahl digestion system.Exemplary safety and reliabilityRobust casing of polyurethaneDistillation time approx.. 3 mins. per sampleDetection limit 0.1 mg NRecovery rate >99.5%Reproducibility ± 1%Steam generating capacity adjustable from 10% - 100%Extremely simple, menu-controlled operation of the programmable units via one single operating element (behr one-button operation)Programmable reaction timeSerial interface (RS232)Filling level monitoring for can setPractical quick clamping device
The S-series steam distillers are the ideal complement to the behr Kjeldahl digestion system.Exemplary safety and reliabilityRobust casing of polyurethaneDistillation time approx.. 3 mins. per sampleDetection limit 0.1 mg NRecovery rate >99.5%Reproducibility ± 1%Steam generating capacity adjustable from 10% - 100%Extremely simple, menu-controlled operation of the programmable units via one single operating element (behr one-button operation)Programmable reaction timeSerial interface (RS232)Filling level monitoring for can setPractical quick clamping device
AlcoholVolatile acid contentsFermentation process (beer, etc.)Ammonium chloride in liquorice productsDistillation units for determining alcohol and volatile acid content in wine and other alcoholic drinks. Complete glassware, with volumetric flasks and pycnometer. Because of its rapidity, the behr D 1 and D 2 are especially suitable for high sample throughputs.
AlcoholVolatile acid contentsFermentation process (beer, etc.)Ammonium chloride in liquorice productsDistillation units for determining alcohol and volatile acid content in wine and other alcoholic drinks. Complete glassware, with volumetric flasks and pycnometer. Because of its rapidity, the behr D 1 and D 2 are especially suitable for high sample throughputs.
The weighing paper is low in nitrogen and dissolves residue-free in acid solutions. Suitable for Kjeldahl analysis.Thin and lightweightTransparent and smooth parchment surfaceEasy weighing and transfer of samplesReliable for quantitative transfer
behrotest readily liberated cyanide glassware kit for DET 5
behrotest total cyanide glassware kit for DET 5
behrotest DET base configuration heating block, controller water cooling distributor
Digestion apparatus with Kjeldahl flasks with glass suction system,6x500 ml,max. 750°C
Digestion apparatus with Kjeldahl flasks with glass suction system,6x750 ml,max. 750°C
CLP-Info
- H411: Toxic to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
Kjeldahl tablets (without addition of Se and Hg) 5 g/tablet