Filter products
Elemental analysis
Cells made of optical glass or Borosilicate glass 3.3, 21 mm x 40 mm, for instument Models Fs, PFXi/PFX195, 880, 950 and 995. (Note: PFXi/PFX-195 max. path length 50 mm).W600/OG/xx for unheated samples (up to 40 °C)W600/B/xx for heated samples (up to max. 100 °C)Further versions available on request.
CLP-Info
- H226: Flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P312: Call a POISON CENTRE/doctor/ if you feel unwell.
- P403+P235: Store in a well-ventilated place. Keep cool.
The test kits have been specially developed for the analysis of boiler, cooling and service water.
For use, for example, with the Nessleriser systems from Lovibond®.
Nessler cylinder AF306P, 113 mm: For use with the Nessleriser 2150 for the measurement of the Pt-Co/Hazen colour discs NSH (10-90 mg Pt/l) and NSB (70-250 mg Pt/l) and NSX (50-300 mg Pt/l).Nessler cylinder DB420, 250 mm: For use with the Nessleriser 2250 for the measurement of the Pt-Co/Hazen colour discs CAA (0-30 mg Pt/l) and CAB (30-70 mg Pt/l).
Watesmo allows the quick and easy detection of water and water vapor in organic solvents.Scope of supply: 1 reel (5 m length, 10 mm width)
The Pooltester is designed for the simultaneous determination of the most popular water treatment agents and the pH value. Each pool tester contains tablets in foil for every 20 analyzes and a multilingual user manual.
Reliable and preciseNon-bleedingEasy and quick analysisMade in Europe
For semi-quantitative determinations.
For determining water hardness.Colour change from green to red.
CLP-Info
- H319: Causes serious eye irritation.
- H351: Suspected of causing cancer .
- P201: Obtain special instructions before use.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
- P337+P313: If eye irritation persists: Get medical advice/attention.
Powder reagents in individually sealed packages.
CLP-Info
- H372: Causes damage to organs through prolonged or repeated exposure .
- P264: Wash thoroughly after handling.
- P314: Get medical advice/attention if you feel unwell.
Measuring tablets DPD Nr. 3 pack of 500
A large selection of water test discs are available for colorimetric chemical analyses and colour classification. Each test disc is equipped with fade-free, non porous glass filters, the quality of which is not impaired by UV light or other environmental influences.Test discs whose code begins with "N", are designed for use in the Nessleriser 2150. All other test discs are designed for use in the comparator 2000+ . The most popular water test discs feature in the table below. Other test discs are available on request.
Initial equipment for HPLC with b.safe-Caps for bottles with thread GL 45. Furthermore fittings for easy connection of capillary tubing, blind fittings for closing unused connections and air valves for a trouble-free withdrawal of solvents are included. For up to 4 storage bottles.Scope of supply: 4 x b.safe-cap GL 45 with 2 connections UNF ¼" 28G, 4 x air valve with service life indicator, 8 x fittings yellow for tubing O.D. 3.2 mm, 4 x blind fittings
Total Organic Carbon (TOC) standards are manufactured from high purity raw materials and are suitable for calibrating of TOC analysers to a high accuracy. These standards are independent, traceable and certified. TOC750P contains preservatives.
Cells made of optical glass 17 mm x 75 mm, for Comparator 2000+ and Comparator 3000 using unheated samples (up to 40 °C).Further versions available on request.
The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid colour control: RCMSi technology (Remote Calibration & Maintenance Service via internet). Users can benefit from the capability for remote calibration and servicing via the internet - eliminating any costs and time delays associated with servicing and guaranteeing compliance with standards. The PFXi range is supplied with a full range of colour scales for specific markets including, but not limited to, Petroleum, Edible Oils, Pharmaceuticals, Brewing and Honey. Users can upgrade scales remotely at any time. Every PFXi is supplied with colour control software for data analysis (LAN & USB cable provided). Optical glass cells, a certified glass calibration filter, a spare lamp and user instructions included. The PFXi-880 and -995 series are available with an optional integrated heater unit. (This is not available for the PFXi-195). This is a critical feature when dealing with materials such as fats and waxes where temperature needs to be maintained at a constant temperature +10°C above the "Cloud Point" of the material.Please Note: CIE values and spectral data readings are standard on all the instruments listed below.
For colorimetric chemical analysis and colour classification. With colour-fast, non-fading glass filters whose quality is not affected by UV light or other environmental influences.Further test discs are available on request.
Lovibond® Comparator 2000+ is a quality instrument for the visual analysis of colour intensity in analysis samples using Lovibond colour discs. The integral cell attachment enables cells with a depth of 40mm to be accepted. The Lovibond® Nessleriser system provides greater depths by using corresponding accessory Nessler tubes. This enables the determination of concentrations below the detection limit of the Lovibond® Comparator 2000+. The integral prism in the Lovibond® Comparator 2000+ brings the glass standard of the colour discs and the colour samples optically into the field of view. The prism is hermetically sealed, preventing the lens from being contaminated. Both the Comparator 2000+ and the Nessleriser are designed in such a way that they compensate for cloudy or coloured water samples. Each device is available for use in daylight or in combination with the artificial daylight unit 2000.
Lovibond® Comparator 2000+ is a quality instrument for the visual analysis of colour intensity in analysis samples using Lovibond colour discs. The integral cell attachment enables cells with a depth of 40mm to be accepted. The Lovibond® Nessleriser system provides greater depths by using corresponding accessory Nessler tubes. This enables the determination of concentrations below the detection limit of the Lovibond® Comparator 2000+. The integral prism in the Lovibond® Comparator 2000+ brings the glass standard of the colour discs and the colour samples optically into the field of view. The prism is hermetically sealed, preventing the lens from being contaminated. Both the Comparator 2000+ and the Nessleriser are designed in such a way that they compensate for cloudy or coloured water samples. Each device is available for use in daylight or in combination with the artificial daylight unit 2000.
Lovibond® Comparator 2000+ is a quality instrument for the visual analysis of colour intensity in analysis samples using Lovibond colour discs. The integral cell attachment enables cells with a depth of 40mm to be accepted. The Lovibond® Nessleriser system provides greater depths by using corresponding accessory Nessler tubes. This enables the determination of concentrations below the detection limit of the Lovibond® Comparator 2000+. The integral prism in the Lovibond® Comparator 2000+ brings the glass standard of the colour discs and the colour samples optically into the field of view. The prism is hermetically sealed, preventing the lens from being contaminated. Both the Comparator 2000+ and the Nessleriser are designed in such a way that they compensate for cloudy or coloured water samples. Each device is available for use in daylight or in combination with the artificial daylight unit 2000.