Filter products
Autoklaves, Accessories
Exhaust hose 1 m
CLP-Info
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P264: Wash thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P337+P313: If eye irritation persists: Get medical advice/attention.
- P362+P364: Take off contaminated clothing and wash it before reuse.
Laboratories are very concerned about hygiene, cleanliness and comfort in the workplace. Try Anabac® autoclave deodorant balls to improve the working environment in the laboratory. These autoclave deodorant balls bring a discrete scent that speaks of cleanliness.
Bowie Dick test compliant with EN ISO 11140-1 Type 2 and EN ISO 11140-4 standards.Equivalent to the test pack indicated in EN 285Plasticized indicator sheet with colour change from pink to blackEach pack is contained in a little, practical box to be inserted directly into the autoclave
Crepe paper, adhesive. With indicator. Colour changes according to DIN EN ISO 11140-1. Rolls of 50 m.
Type 4 indicators Stericontrol Steam are multiparameter indicators designed to react to the critical steam sterilization process parameters.Multiple variable indicator for 121/134 °C steam cyclesComplies with EN ISO 11140-1 Type 4 standard
The stripes change color once the ambient temperature reaches steam sterilisation temperature level. Irreversible color change from pale yellow to dark brown proves that the sterilisation protocols has been successfully covered. Adhesive at the back of the rolled paper strongly adheres to paper, plastic and textile surfaces yet easily removable without leaving any trace. Slightly crepped paper surface allows easy marking by any kind of pen.
Permanent filterset for polySteribox® SH
polySteribox® L with annual filter
This device is the innovative solution for the simultaneous and continuous detection of up to five gases. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. The device can be equipped with three electrochemical, and two catalytic bead, infrared or photoionisation sensors. It is the ideal companion in a great number of applications where reliable monitoring of oxygen, toxic and combustible gases and vapors in ambient air is necessary.Basic unit with rubber-boot, carrying strap, calibration adapter, water and dust filter. In order to get a fully operational unit, a power pack and up to 5 sensors have to be ordered. And, optionally, a built-in pump or a datalogger can be ordered.
Feed water autom. HG50
Device lid, inox, for STERI 250/350
Solit basket for AE-AES-28 stainless steel, Ø 280mm, H 200mm, non perforated
Biological control involves the use of indicators, which check whether all microorganisms were killed during the sterilisation process. The bio-indicators are unique, as they directly indicate how many microbial spores have actually been killed. Thanks to the reliability and quality of the information, the regular use of a bio-indicator can lead to an improvement in the performance of the sterilisation process and thus to better results.Features:No external laboratory is required for performance evaluationEasy handlingReasonable to use after repairs or maintenance of autoclavesApplication:Program 3.5 minutes, holding time at 121 °C or 134 °CAfter sterilisation, break the vial in order to bring the nutrient solution into contact with the spore strip
Flat bath cover with 4 openings Ø 92 mm, and set of rings, for PURA 10
For welding all polyethylene, polypropylene, cellulose or polyamide foils up to a thickness of 2 x 0.25 mm. Expandable with a plug-in table and a film roll-off device. With cutting device and double-sided heating tape clamping device. M model sealers have an additional holding magnet as well as a welding and cooling automatic.
Lift-up bath cover, for PURA 4 transparent, up to +100°C
Connecting equipment and fittings with GL threads with hard-walled tubing or tubes made of glass, plastic or metal. Fixing probes, thermometers, dip tubes or cables in reaction vessels. Black screw caps made of PPS, inner parts consisting of a v-ring (PPS), a tapered ring and a sealing ring (both PTFE) as well as an o-ring (FKM) for tubing diameters under 3 mm (not exposed to the medium). Good chemical resistance, the medium is only exposed to PTFE. Temperature resistant from -50 to 250 °C, pressure stable up to 10 bar, suitable for vacuum.
Fast and secure connection for liquids, gases, compressed air and vacuum. Rapid couplings are ideal when connecting and separating hoses, machines, apparatus and containers. Thanks to the secure O-ring seal, the quick-release couplings are guaranteed to be leak-proof. All couplings and nipples can be inserted into each other within the same flow size.
The DURAN® Screw Cap GL 45 thermocouple holder consists of a holder fitted into a blue DURAN® polypropylene GL 45 cap that accepts up to three separate thermocouple wires used in autoclaves or sterilizers.Applications"Loaded Chamber heat penetration" tests during Performance Qualification (PQ)Routine sterilization /autoclave cyclesPerformance tests after autoclave maintenance or repairFeaturesUsable with DURAN® original GL 45 laboratory bottles (1000 ml or less).The 240 mm PTFE tube may be cut to lengthSuitable for holding up to three separate thermocouple wires (Conductor sizes 1/0.3 mm, 1/0.5 mm or 7/0.2 mm)Retrace code for product traceability and downloadable certificate
The DURAN® temperature probe holder GL 45 consists of a stainless steel holder that is permanently fitted into a blue DURAN® polypropylene GL 45 cap. The holder will accept the 6.0 mm metal temperature measuring probes that are commonly used in laboratory autoclaves and sterilizers.ApplicationsRoutine sterilization /autoclave cycles"Loaded Chamber heat penetration" tests during Performance Qualification (PQ)Performance tests after autoclave maintenance or repairFeaturesUsable with DURAN® original GL 45 laboratory bottles (1000 ml or less).The depth of the probe can be adjusted to suit the bottle sizeAdjustable ferrule suitable for 6.0 mm diameter probesRetrace code for product traceability and downloadable certificateEasy positioning of the sensor in the middle of the bottle