Filter products
Autoclaves
Circulation cooler Minichiller 600w OLÉ -20...+40°C, water-cooled 230 V / 50/60 Hz
Standing autoclave Tuttnauer 2840 ELV-C-G-D vertical, 28 ltr., incl. recooling and steam maker, 280x400mm
Initiation 3850/3870 incl.transport to location, isntallation, initiation and control of installation
LabStar 25 Equipment variant "Dry Lab
Table autoclave Tuttnauer 3840 EL-D 52 ltr., 380x400mm incl. heating
Sterilizing box HMT 230 FA/MA 345 x 183 x 125 mm, with lid, side walls with boring that can be closed
Insert with 4 trays for sterilising small items and pipette boxes
The features of the laboratory autoclave line are specifically designed for most common laboratory applications and can be used for the sterilzation of liquids, instruments, glass, waste and for the preparation of nutrient media.Stores the last 200 cycles in built-in memoryOption: second flexible Pt 100 probe30 Identification Codes and Passwords for access level controlThe controller and software comply with the 21 CFR part 11 standardFilter replacement notifications based on the number of cyclesData archiving via USB interfaceDouble sterilization time monitoringIn/Out test (enables technicians to check each system component separately)Sterilization temperature range up 105 °C to 137 °COptional Disinfection/Isothermal Temperature range from 60°C to 105°C7 standard sterilisation programsOptions available:Fast cooling technology and ventilator to reduce cooling time additionallyVacuum pump to evacuate residual airExhaust air filtrationLifting device to elevate/to lower heavy sterilzation goodsPrinter to document the performed cycle (Please order separately)R.PC.R software allows complete control and monitoring of the autoclave
The features of the laboratory autoclave line are specifically designed for most common laboratory applications and can be used for the sterilzation of liquids, instruments, glass, waste and for the preparation of nutrient media.Stores the last 200 cycles in built-in memoryOption: second flexible Pt 100 probe30 Identification Codes and Passwords for access level controlThe controller and software comply with the 21 CFR part 11 standardFilter replacement notifications based on the number of cyclesData archiving via USB interfaceDouble sterilization time monitoringIn/Out test (enables technicians to check each system component separately)Sterilization temperature range up 105 °C to 137 °COptional Disinfection/Isothermal Temperature range from 60°C to 105°C7 standard sterilisation programsOptions available:Fast cooling technology and ventilator to reduce cooling time additionallyVacuum pump to evacuate residual airExhaust air filtrationLifting device to elevate/to lower heavy sterilzation goodsPrinter to document the performed cycle (Please order separately)R.PC.R software allows complete control and monitoring of the autoclave
Autoclave HMT 232 N with UK-Plug -tabletop unit, semi-automatic - chamber volume: 16l
Autoclave HS-100 MSV Chamber volume (liters): 100 Power supply (V): 3x230 / 400V
Autoclaves,HV-25,temperature range 60-100°C chamber size 240x550 mm,cap. 25 ltrs,up to 1.9
Automatic autoclaves AE-110 B
Automatic autoclaves AE-110 DRY
Automatic autoclaves AE-150 DRY
Automatic autoclaves AE-28-DRY
Automatic autoclaves AE-50 DRY
Automatic autoclaves AE-75 B
Automatic autoclaves AE-75 DRY
AUTOMATIC AUTOCLAVES AES-28