Filter products
Cleaning and disinfection for instruments
Disinfection set for arium® 611 for disinfection syringes with sodium hypochlorite < 1%
70 % Isopropylalcohol for cleaning, single packed, non sterile, unfolded approx. 60 x 30 mm.100 pcs/box, 2000 pcs/carton.
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H400: Very toxic to aquatic life.
- H411: Toxic to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Mild alkaline liquid cleaning agent for use in special washing machines.neodisher® Alka 300 is mildly alkaline and removes blood, protein residues and organic residues.Instrument steel, chrome nickel steel, chromium-plated and nickel-plated materials, pure aluminium, aluminium-magnesium alloys and ordinary plastics are not affected. Suitability tests should be carried out before use in the case of special instruments, e.g. optical instruments or anaesthetic and respiration materials, as well as anodised aluminium.neodisher® Alka 300 can be used with any level of water hardness, but should generally be used with softened water for reasons of economy.
CLP-Info
- EUH210: Safety data sheet available on request.
pH-neutral, cleaning agent for surgical instruments, anaesthesia equipment and other medical utensils, liquid.Also suitabel for stainless steel, instrument steel, light metals, glass, the usual plastics and the materials of anaesthesia equipment and flexible endoskopes are resistant to working solutions of neodisher MediZym.
CLP-Info
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P337+P313: If eye irritation persists: Get medical advice/attention.
Mildly alkaline cleaner for the manual cleaning of laboratory glassware in immersion baths, powder.Self-acting cleaning performance against blood, proteins, food residues, inorganic and organic residues. Excellent material compatibility. Very easy to rinse off.
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H410: Very toxic to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Alkaline liquid cleaner, 5 l, for specialised machine cleaning of laboratory glassware and laboratory equipment.Note on the use of cleaning agents containing active chlorineOxidising effect, free from surfactantsSpecially formulated for Miele Professional laboratory dishwashersSuitable for stainless steel, laboratory glassware, ceramics and plasticEffective cleaning of organic soiling
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Alkaline liquid detergent, 10 l, with the EU Ecolabel, for cleaning everyday dirt from crockery, cutlery and glasses.Phosphate- and chlorine-freeParticularly suitable for washing glassesFor use in commercial dishwashersLiquid concentrate for automatic dosing
CLP-Info
- H314: Causes severe skin burns and eye damage.
- H410: Very toxic to aquatic life with long lasting effects.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P391: Collect spillage.
- P501: Dispose of contents/container to
For laboratory glass devices and instruments, washable surfaces of all types such as floors, walls, bath tubs, sinks, fittings, toilets, cabinets, doors, etc. For use in all areas with a risk of infection, such as hospitals, doctors' practices, the pharmaceutical and food processing industry. Also suitable for senior citizen and nursing homes, schools, kindergartens and large kitchens. The formulation has been tested pursuant to the DGHM VII and DVG (food) directives for surface disinfection and found to be effective in the specified working concentrations. Excellent results in case of high protein load.Cleans and disinfects in a single working operationBactericide, fungicide, virus inactivating in case of hepatitis B and HIV.Non-corrosive in case of common materialsRinses off without leaving residueEconomical: 0.8 to 2 % working solution
CLP-Info
- H314: Causes severe skin burns and eye damage.
- H335: May cause respiratory irritation.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P310: Immediately call a POISON CENTER/doctor/
Powder alkaline, free from phosphates. Material protection and good cleaning performance on inorganic and organic soils.Suitable for: Stainless steel, laboratory glassware, ceramics, suitable plastics (PE, PP, PVDF, PTFE)Not suitable for: Light alloys and non-ferrous metals, aluminium, anodised aluminium
CLP-Info
- H314: Causes severe skin burns and eye damage.
- H335: May cause respiratory irritation.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Powder mildly alkaline, foam-inhibiting, free from oxidants. Good cleaning performance on blood, protein and food residue, good protection against corrosion for laboratory glassware, stainless steel, chrome-plated items, laboratory equipment made from common types of plastic.Suitable for: Stainless steel, laboratory glassware, ceramics, suitable plastics (PE, PP, PVDF, PTFE)Not suitable for: Anodised aluminium
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H412: Harmful to aquatic life with long lasting effects.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Alkaline liquid detergent, 10 l, for removing stubborn dirt from crockery, cutlery and glasses.Contains active chlorine and phosphateReliably removes burnt-on and dried-on food residuesFor use in commercial dishwashers (excluding ProfiLine)Liquid concentrate for automatic dosingSpecially developed formula for Miele Professional
CLP-Info
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P337+P313: If eye irritation persists: Get medical advice/attention.
Liquid detergent, mildly alkaline, 10 l, for cleaning light soiling from crockery, cutlery and glasses.Phosphate- and chlorine-freeRemoves light soiling from fresh foodFor use in commercial dishwashersLiquid concentrate for automatic dosingSpecially developed formula for Miele ProfessionalLow hazard classification, minimal safety precautions required when handling
CLP-Info
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P337+P313: If eye irritation persists: Get medical advice/attention.
Powder detergent, mildly alkaline, for cleaning heavily soiled crockery, cutlery and glasses.Contains active oxygen and phosphateReliably removes burnt-on and dried-on food residuesFor use in commercial dishwashersPowder detergent for manual dosing
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H318: Causes serious eye damage.
- P102: Keep out of reach of children.
- P234: Keep only in original packaging.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P332+P313: If skin irritation occurs: Get medical advice/attention.
- P338: Remove contact lenses, if present and easy to do. Continue rinsing.
- P405: Store locked up.
Alkaline cleaning concentrate for the cleaning of organic and inorganic alkali-proof spectacles, moulds and high precision optics, gemstones, quartz, ceramics and selected plastics. Also for steel, iron steel and titanium surfaces. For the removal of resin, putty/glue, adhesives and traces of selected organic plastics from moulds (e.g. CR 39). Check plastics for compatibility before use. Do not use for light metal (Al, Mg), zinc and tin surfaces.
CLP-Info
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P332+P313: If skin irritation occurs: Get medical advice/attention.
Alkaline universal cleaning concentrate for laboratory instruments and work pieces made of glass, alkaline-resistant plastics, ceramics, rubber (excellent for breathing masks), metals, non-ferrous metals, also light metals. It removes contaminations such as oils, fats and greases, dust, soot, cokings, etc.
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Mildly alkaline, foam-inhibited cleaning concentrate for dip and splash cleaning of laboratory instruments made of metal, glass, ceramic, plastic materials and for glassware. Removes gentle markings, labels, lime soap deposits, greases and oils (incl. greases for ground-glass joints, weakly resinified greases).Check aluminium, magnesium and generally alloys of light-metals before application.
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P332+P313: If skin irritation occurs: Get medical advice/attention.
- P405: Store locked up.
Strongly alkaline, foam-inhibited cleaning concentrate for ultrasonic, immersion and splash cleaning of alkali-resistant parts and laboratory instruments, made of metal (including titanium), glass, ceramic and plastic. Removes biological contaminants, grease, oil, abrasives and polishing pastes, resinified and tarry residues, marker and label residues.Not suitable for aluminium, magnesium, alloys of light metals and alkali-sensitive glass. Risk of tarnishing when used for nonferrous metals.
CLP-Info
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308: IF exposed or concerned:
- P310: Immediately call a POISON CENTER/doctor/
Acidic, foam-inhibited cleaning concentrate for ultrasonic, immersion and splash cleaning of acid-resistant medical and laboratory instruments made of stainless steel, glass, ceramic and plastic. Removes mineral contamination like lime scales, lime soaps, metal oxides and flux residues after soldering, mineral oils and greases.Not suitable for aluminium, magnesium and light metal alloys. Check acid-sensitive glassy materials before application.
CLP-Info
- H318: Causes serious eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Concentrates for SONOREX ultrasonic cleaning baths. Enhances cavitation, cleans intensively, kind to most materials and free from chloride. For use cold or warmed up.Special cleaner, concentrate. Properties: weak acid pH 3.0 at 1%, dosage 5%. Based on: citric acid, surfactants, without phosphate. For: steel, stainless steel, non-ferrous, precious and light metals, glass, ceramics, plastics, rubber. Removes: mineral residues, flash rust, grease, oils, waxes, pigments, grinding, polishing and lapping residues.
Replacement UV-lamp Omnia 185