Filter products
Vials, Septa
Screw neck vials ND13 with 13-425 thread made of clear and amber first hydrolytic class glass facilitate easy filling with viscous substances thanks to their wide opening.The LABSOLUTE® vials for optimised micro-sampling are the best solution for very small sample volumes.
The screw cap 7.622 166 for bottle 7.622 167 has to be ordered separately.
Screw neck vials and micro-vials ND8 are available in clear and amber first hydrolytic class glass. They have a 8-425 thread and are used as standard in GC and HPLC applications. A large selection of micro-inserts with a 5 mm diameter is available for these vials. The micro-vials often require an adapter so that they can be used in an autosampler.These vials are especially used with autosamplers made by Beckman, Shimadzu, Spark, Varian and VWR/Hitachi.
The LABSOLUTE® kits ND24 contain shrink-wrapped screw vials ND24 made of clear or amber first hydrolytic class glass and corresponding screw caps made of PP.
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 8 mm septa can be used with the following caps:8 mm screw caps (ND8)8 mm crimp caps (ND8)Septa with a double-sided PTFE coating show a very low particle formation during penetration.
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 11 mm septa can be used with the following caps:11 mm crimp caps (ND11)Septa with a double-sided PTFE coating show a very low particle formation during penetration.
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 11 mm septa can be used with the following caps:11 mm crimp caps (ND11)Septa with a double-sided PTFE coating show a very low particle formation during penetration.
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 12 mm septa can be used with the following caps:13 mm screw caps (ND13)Septa with a double-sided PTFE coating show a very low particle formation during penetration.
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 20 mm septa can be used with the following caps:20 mm screw caps (ND20)
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 8 mm septa can be used with the following caps:8 mm screw caps (ND8)8 mm crimp caps (ND8)Septa with a double-sided PTFE coating show a very low particle formation during penetration.
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 8 mm septa can be used with the following caps:8 mm screw caps (ND8)8 mm crimp caps (ND8)Septa with a double-sided PTFE coating show a very low particle formation during penetration.
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 8 mm septa can be used with the following caps:8 mm screw caps (ND8)8 mm crimp caps (ND8)Septa with a double-sided PTFE coating show a very low particle formation during penetration.
The GC septa are universal and longlife. They are delivered in resealable screw neck vials of 1st hydrolytic class and ready-to-use. You have several advantages using our GC septa:Suitable for inlet temperatures up to 400 °CLow release of siloxanesGood penetration and sealing propertiesNo sticking to hot surfacesThe septa can be used for the instruments of the following manufacturers:7.629 437 Agilent, Varian, Varian (CP), Tracor, Gow-Mac, Finnigan, Antek Unicam7.648 606 Agilent, Varian7.635 081 Agilent, Varian, Gow-Mac, Perkin Elmer7.639 885 Thermo Scientific Quest, Fisons/Carlo Erba, Finnigan
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 20 mm septa can be used with the following caps:20 mm screw caps (ND20)
The septa are especially designed for the screw caps with GL thread.
The choice of the right septa depends on the application. Many septa are PTFE coated on one side. PTFE is highly resistant against many chemicals and forms an inert border between the sample and the base material of the septa.The septa's base material has various physical and chemical properties, like temperature resistance, resealability, cleanliness, hardness and thickness.Natural rubber/TEF- Temperature-resistant from -40 °C to 120 °C- Excellent resealability properties- Inexpensive for standard applications in the fields of GC and HPLCRedRubber/PTFE- Temperature-resistant from -30 °C to 110 °C- Softer and therefore easier to penetrate than natural rubber- Not as good resealability properties as natural rubber- Higher chemical purity than natural rubber- Inexpensive for standard applications in the fields of GC and HPLCButyl/PTFE- Temperature-resistant from -40 °C to 120 °C- Higher chemical purity than natural rubber and RedRubberSilicone/PTFE- Temperature-resistant from -60 °C to 200 °C- More suitable for single-injection applications- Much higher chemical purity than natural rubber and RedRubber- Very low particle formation during penetration in case of double-sided PTFE coating- Best for the thin and fragile needles of the autosampler- Best for critical analysis (UltraClean quality)The 12 mm septa can be used with the following caps:13 mm screw caps (ND13)Septa with a double-sided PTFE coating show a very low particle formation during penetration.
The shell vials made of clear or amber first hydrolytic class glass come in a set with transparent PE plugs. The star-shaped diaphragm in the plug facilitates easy penetration.This easy-to-use, inexpensive vial/plug combination is suitable for non-critical analyses, especially in the field of HPLC.Please select a vial/seal combination with insertion barrier like 7.620 436 or 7.616 878 if micro-inserts are used. The penetration of the seal is slightly more difficult due to the insertion barrier.
Shell vial, clear glass, 1. hydrolytic class, 1.0 ml, 35 x 7.8mm, with PE stopper, for Alcott, pack of 100, LABSOLUTE®
Short thread vials and micro-vials ND9 are available in clear and amber first hydrolytic class glass and can be used on almost all autosamplers. You can replace other 1.5 ml vial types like 11 mm crimp neck vials, 8-425 and 10-425 screw neck vials, which can help rationalize stocks.The wide opening requires matching micro-inserts with 6 mm diameter.Due to the technical geometry, the vails can be used on all common autosamplers, but preferentially on instruments made by Agilent, HTA, Shimadzu, Thermo Scientific, Varian and Waters.
The short thread vials ND9 SureStop are available in clear and amber first hydrolytic class glass and are the best available on the market in terms of seal tightness and reliability. The vials have an additional stopper ring at the end of the thread which clearly marks the end point in the screwing-in process. This ensures that the tightness of the seal is independent of the touch or feel of the user screwing the stopper in. This ensures the lowest possible number of standard deviations and high reproducibility of analysis results.