Filter products
Mass spectroscopy
ECD-Anode f. 9000-Autosystem N6100132
ELECTROSPRAY CALIBRANT SOLUTION (100 ML)
FID Electrometer PCA (RoHS)
Filament assembly, for Agilent 5971 MSD
FILAMENT, RHENIUM(RE) ALLOY 3 X 0,1 /PK AGILENT
Tapered Quartz Injector 2.5mm
GLASS TIPS, STANDARD COATING, VE = 20STK.
GLASS TIPS, STANDARD COATING, VE = 20STK.
Graphite cone 1/8 ", bore 0.5mm, for q
Headspace Crimp Kappen, 20 mm Durchmesser, PTFE-Coated Silicone Rubber Septum, 1000/ PAK
HF Induction coil for the Elan DRC-e / DRC II / 9000 / 6x00 ICM-MS spectrometer as well as the Nexion 300 Q / X / D / S. Complete with all necessary connections, self-adjusting
High Sensitivity Glass Cyclonic Spray Chamber für NexION 1000/2000
I-AS autosampler rinse bottle, external, 100 mL, with caps, 6/pk. Polypropylene (PP) 100 mL rinse bottles compatible with Agilent Integrated Autosampler (I-AS)
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H350: May cause cancer .
- H412: Harmful to aquatic life with long lasting effects.
- EUH071: Corrosive to the respiratory tract.
- P202: Do not handle until all safety precautions have been read and understood.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
ICP MULTI-ELEMENT STANDARD SOLUTION IX (9 ...) 100 MG/L: AS, BE, CD, CR(VI), HG, NI, PB, SE, TL CERTIPUR
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H350: May cause cancer .
- P202: Do not handle until all safety precautions have been read and understood.
- P234: Keep only in original packaging.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
ICP Multielement Standard Solution VIII Certified Reference Material (24 elements in dilute nitric acid) Certipur®
ICP-MEHRELEMENTSTANDARDLOESUNGXXII FUER MS ZUR ICP MS ... 0 ,2MG/L: CD, CU, MG, PB, RH CER
ICP-MS Chiller Coolant Mix, 1 L Bottle
Immension tube made os synthetic Quartz
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Indium standard solution traceable to SRM from NIST In (NO3)3 in HNO3 0.5 mol/l 1000 mg/l In Certipur®