Thread size UNF 1/4" 28GLuer Lock adapterPTFE FilterValve membrane blocks vapours and opens at negative pressureIt is recommended to replace the valve every 6 monthsWith change indicator and labelling field for timely change
PTFE Plug for charcoal filter port
The exhaust air filters are equipped with three different activated carbon layers, which bind acids and alkalis and adsorb organic solvent vapours. Depending on the required capacity, filter with different service lifes are available.Filter media with a very high performance spectrum for acids and alkalisOptimised for binding buffer solutions and solvent vapoursWith splash guard1500 m²/g adsorption surface area
Flanged PTFE tubing with black tube end fittings UNF ¼" 28 G made of PP and washers made of PA. The tubing is ready for use. Temperature resistant from 0 to +100 °C, pressure resistant up to 30 bar, universal chemical resistance.
For safe transfer of liquid media within a closed and sterile system (evaporation is reduced).Screw closure GL 45 with two, three or four ports GL 14 threadAutoclavableTemperature restistant up to max. 140 °CFlexible modular systemSterile pressure equalisation is possible through use of a membrane filterUnused ports can be provided with a blind cap
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.Complete set for one HPLC system with up to 4 solvent reservoirsPrice advantage compared to ordering piece by pieceSuitable for all current HPLC systemsUse the supplied blind plugs to tighten connectors which are temporarily inactive or not in useScope of supply: 3 x SafetyCaps I, 1 x SafetyCap II, 4 x air valve, 4 x change indicator, 5 x 1,6/ 5 x 2,3/ 5 x 3,2 mm PFA fittings, 1 x PFA blind plug, 4 x labelling field
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.Complete set for one HPLC system with up to 4 solvent reservoirsPrice advantage compared to ordering piece by pieceSuitable for all current HPLC systemsUse the supplied blind plugs to tighten connectors which are temporarily inactive or not in useScope of supply: 4 x SafetyCaps II, 4 x air valve, 4 x change indicator, 8 x 1,6/ 8 x 2,3/ 8 x 3,2 mm PFA fittings, 4 x PFA blind plugs, 4 x labelling field
DURAN® reagent bottles, DIN thread, ISO 4796. Pressure resistance, as a result of amended shape, in the range of -1 up to +1.5 bar (tested by the TÜV in accordance with DIN EN 1595, with GS mark). Neutral / Type 1 glass in accordance with USP/EP. With Retrace code (Batch identification). Certificate available via the Internet. Autoclavable.Please order cap and pouring ring separately.
Replacement caps for 1,6-2/2,1-4mm
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.Scope of suppy:Safety Cap, air valve, change indicator, PFA fittings, PFA blind plug, labelling field
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, mm PFA fittings, PFA blind fittings, hose olive, PTFE blind fittings, labeling field
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, PFA blind fittings, PTFE blind fittings, hose olives
Use SafetyCaps and SafetyWasteCaps also for bottles with GL40 or GL38 thread. Further adapters in different thread sizes are available on request.
3 port collector for leak connector, sidewise 3x Leak, without connectors
For space saving mounting on b.safe Waste Caps.
For assembly of an exhaust filter on a capillary connection.
For installation of capillaries at exhaust filter connection of b.safe Waste Caps. The adapter made of PE-EX is conductive.
Space problems in the lab? Use the adapters for the exhaust filter to gain more free space. Attach the exhaust filter in any position - perfect when dealing with lower installation heights.
Screw caps, with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator.Scope of supply:fittings (PFA), blind fittings (PFA), air valve