Filter products
Devices for oxygen determination
CLP-Info
- H314: Causes severe skin burns and eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Portable routine model for dissolved oxygen measurement.New, intuitive menu structure with fast and easy T-Pad navigationRobust design with IP 67 protection for use in harsh and demanding environmentsIntelligent Sensor Management (ISM®) functionality reduces the risk of errorsUp to 2 calibration points and a choice of 2 predefined oxygen standardsAutomatic, manual and time dependant endpoint recordingData memory storage for 200 data pointsPower requirements: 4 x 1.5 V AA or 1.3 V NiMH rechargeable batteriesScope of supply: Includes instrument, electrode clip, operating instructions, quick guide, test certificate, declaration of conformity, batteries, InLab 605-ISM, zero oxygen tablets, bottles for calibration, uGo™ carrying case
Portable routine model for dissolved oxygen measurement.New, intuitive menu structure with fast and easy T-Pad navigationRobust design with IP 67 protection for use in harsh and demanding environmentsIntelligent Sensor Management (ISM®) functionality reduces the risk of errorsUp to 2 calibration points and a choice of 2 predefined oxygen standardsAutomatic, manual and time dependant endpoint recordingData memory storage for 200 data pointsPower requirements: 4 x 1.5 V AA or 1.3 V NiMH rechargeable batteriesScope of supply: Includes instrument, electrode clip, operating instructions, quick guide, test certificate, declaration of conformity, batteries, InLab 605-ISM, zero oxygen tablets
Portable professional model for dissolved oxygen measurement.New, intuitive menu structure with fast and easy T-Pad navigationRobust design with IP 67 protection for use in harsh and demanding environmentsIntelligent Sensor Management (ISM®) functionality reduces the risk of errorsNew sunlight-proof screen guarantees screen readability even in direct sunlightNew StatusLight gives a fast, visual confirmation showing if the meter is ready to measure or notOperating support for 12 languages with information shown in complete words and sentenceUp to 2 calibration points and a choice of 2 predefined oxygen standardsAutomatic, manual and time dependant endpoint recordingData memory storage for 2000 GLP data points with weatherproof Micro-USB connection for data exportPower requirements: 4 x 1.5 V AA or 1.3 V NiMH rechargeable batteriesScope of supply: Includes instrument, LabX® direct pH, USB cable, electrode clip, base accessory, operating instructions, quick guide, test certificate, declaration of conformity, batteries, InLab® OptiOx™, zero oxygen tablets, bottles for calibration, uGo™ carrying case, BOD adapter, BOD application note
Portable professional model for dissolved oxygen measurement.New, intuitive menu structure with fast and easy T-Pad navigationRobust design with IP 67 protection for use in harsh and demanding environmentsIntelligent Sensor Management (ISM®) functionality reduces the risk of errorsNew sunlight-proof screen guarantees screen readability even in direct sunlightNew StatusLight gives a fast, visual confirmation showing if the meter is ready to measure or notOperating support for 12 languages with information shown in complete words and sentenceUp to 2 calibration points and a choice of 2 predefined oxygen standardsAutomatic, manual and time dependant endpoint recordingData memory storage for 2000 GLP data points with weatherproof Micro-USB connection for data exportPower requirements: 4 x 1.5 V AA or 1.3 V NiMH rechargeable batteriesScope of supply: Includes instrument, LabX® direct pH, USB cable, electrode clip, base accessory, operating instructions, quick guide, test certificate, declaration of conformity, batteries, InLab® OptiOx™ with protective guard, zero oxygen tablets, bottles for calibration, uGo™ carrying case
Portable professional model for dissolved oxygen measurement.New, intuitive menu structure with fast and easy T-Pad navigationRobust design with IP 67 protection for use in harsh and demanding environmentsIntelligent Sensor Management (ISM®) functionality reduces the risk of errorsNew sunlight-proof screen guarantees screen readability even in direct sunlightNew StatusLight gives a fast, visual confirmation showing if the meter is ready to measure or notOperating support for 12 languages with information shown in complete words and sentenceUp to 2 calibration points and a choice of 2 predefined oxygen standardsAutomatic, manual and time dependant endpoint recordingData memory storage for 2000 GLP data points with weatherproof Micro-USB connection for data exportPower requirements: 4 x 1.5 V AA or 1.3 V NiMH rechargeable batteriesScope of supply: Includes instrument, LabX® direct pH, USB cable, electrode clip, base accessory, operating instructions, quick guide, test certificate, declaration of conformity, batteries, InLab® OptiOx™, zero oxygen tablets
SevenExcellence S900, DO/BOD expansion unit with InLab® OptiOx, BOD adapter
Portable dissolved oxygen meter for field work. Thanks to its ergonomic design, handling the FiveGo™ is a comfortable experience. The foldable stand provides optimal viewing on flat surfaces.A large, well-structured display, intuitive button arrangement and simple menu ensure measurements can be performed in just a few clicksTemperature compensation: ATC and MTCCalibration: 2 points, 100 % and 0 %Memory: 200 measurements, current calibrationScope of supply: Meter only
AL20 OXI Set completely in transport-case
FiveGo FG4-KITmeasuring unit solved oxygen with access.: sensor LE621, temperature probe N
Leak detector testo 316-3
Leak detector testo 316-4 set 2 for ammonia (NH3), incl. sensor head KM, case, charge power supply, earbuds
CLP-Info
- H302+H312+H332: Harmful if swallowed, in contact with skin or if inhaled
- H314: Causes severe skin burns and eye damage.
- H318: Causes serious eye damage.
- P102: Keep out of reach of children.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
MultiTest med.Int.
O2 hand meter SD310Oxi incl.batteries and user manual oxygen sensor w. 10m cable
Oxymètre DO450 étanche, transportable, à résolution optique, avec une précision de ± 2 %, ECDOWP45003K
Oxygen meter inoLab® Oxi 7310P Set 1 unit with built-in printer, incl. CellOx® 325 and acc
Oxzgen meter inoLab® Oxi 7310P Set 4 unit with built-in printer, incl. StirrOx® G and acce
Portable Oxi-Meter Oxi 3205-Set 2 in kit compl. with CellOx® 325 and accessories
Portable oxygen meter watertight, with graphic display, USB, cpl. in transport case
Portable routine model for dissolved oxygen measurement.New, intuitive menu structure with fast and easy T-Pad navigationRobust design with IP 67 protection for use in harsh and demanding environmentsIntelligent Sensor Management (ISM®) functionality reduces the risk of errorsUp to 2 calibration points and a choice of 2 predefined oxygen standardsAutomatic, manual and time dependant endpoint recordingData memory storage for 200 data pointsPower requirements: 4 x 1.5 V AA or 1.3 V NiMH rechargeable batteriesScope of supply: Includes instrument, electrode clip, operating instructions, quick guide, test certificate, declaration of conformity, batteries
Portable professional model for dissolved oxygen measurement.New, intuitive menu structure with fast and easy T-Pad navigationRobust design with IP 67 protection for use in harsh and demanding environmentsIntelligent Sensor Management (ISM®) functionality reduces the risk of errorsNew sunlight-proof screen guarantees screen readability even in direct sunlightNew StatusLight gives a fast, visual confirmation showing if the meter is ready to measure or notOperating support for 12 languages with information shown in complete words and sentenceUp to 2 calibration points and a choice of 2 predefined oxygen standardsAutomatic, manual and time dependant endpoint recordingData memory storage for 2000 GLP data points with weatherproof Micro-USB connection for data exportPower requirements: 4 x 1.5 V AA or 1.3 V NiMH rechargeable batteriesScope of supply: Includes instrument, LabX® direct pH, USB cable, electrode clip, base accessory, operating instructions, quick guide, test certificate, declaration of conformity, batteries