Filter products
Hardness measurement
Shore comparison plates 7 calibration plates, up to +/- 2 HA tolerance
The Leeb hardness tester measures metallic samples and offers mobility and flexibility compared to stationary tabletop devices and testing devices with internal sensor.External impact sensorAll measurement directions possible (360°) thanks to an automatic compensation functionInternal memory for up to 600 data groupsMini statistics function: displays the measured result, the average value, the impact direction, date and timeMeasurement value display: Rockwell (Type A, B, C), Vickers (HV), Shore (HS), Leeb (HL), Brinell (HB)Automatic unit conversion: The measuring result is automatically converted into all specified hardness unitsMeasuring with tolerance range (limit-setting function):Upper and lower limiting can be programmedAcoustic and visual signalMatrix display: Backlit multi-function displayRobust metal housingScope of supply:HK-D: Mobile Leeb hardness tester, hard carrying caseHK-DB: Mobile Leeb hardness tester, hard carrying case, standard block for calibration, hardness approx. 800 HLD
CLP-Info
- H226: Flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P312: Call a POISON CENTRE/doctor/ if you feel unwell.
- P403+P235: Store in a well-ventilated place. Keep cool.
The test kits have been specially developed for the analysis of boiler, cooling and service water.
For hardness comparison plates SAUTER AHBA-01 and SAUTER AHBD-01
For Shore hardness testing of plastics, leather etc.Glass plate: high measurement accuracy by means of superior hardness of the glass plateMechanical construction: Robust design enables accurate measuring movementsLevel adjustment: For the precise levelling of the base plate, e.g. for the correction of inhomogeneous test objectsHardness tester is not included with deliveryOperation:1. The SAUTER hardness testing device HDA/HD0 is fitted in a suspended position2. The test object is placed on the round testing table right under the durometer measuring tip3. By pressing the lever down, the test weight will be released, and this then presses the measuring tip into the test object with its own weight (see test force hardness measurement)The accuracy of the displayed result is about 25 % higher than in a manual operated test
For Shore hardness testing of plastics, leather etc.Glass plate: high measurement accuracy by means of superior hardness of the glass plateMechanical construction: Robust design enables accurate measuring movementsLevel adjustment: For the precise levelling of the base plate, e.g. for the correction of inhomogeneous test objectswith exchangeable longer column for use with digital hardness tester HDHardness tester is not included with deliveryOperation:1. The SAUTER hardness testing device HDD is fitted in a suspended position2. The test object is placed on the round testing table right under the durometer measuring tip3. By pressing the lever down, the test weight will be released, and this then presses the measuring tip into the test object with its own weight (see test force hardness measurement)The accuracy of the displayed result is about 25 % higher than in a manual operated test
For Shore hardness testing of plastics, leather etc.Glass plate: high measurement accuracy by means of superior hardness of the glass plateMechanical construction: Robust design enables accurate measuring movementsLevel adjustment: For the precise levelling of the base plate, e.g. for the correction of inhomogeneous test objectsHardness tester is not included with deliveryOperation:1. The SAUTER hardness testing device HBD is fitted in a suspended position2. The test object is placed on the round testing table right under the durometer measuring tip3. By pressing the lever down, the test weight will be released, and this then presses the measuring tip into the test object with its own weight (see test force hardness measurement)The accuracy of the displayed result is about 25 % higher than in a manual operated test
Durometer model A measuring range: 0-100 Shore 102 x 57 x 44 mm
Hardness HR titration solution TH4 65ml
Härteprüfstab mit 3 Spiralfedern
CLP-Info
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Minikit Gesamthärte AF 446 (Speed Test)
GYZJ-6-5 Indentor point for Barcol Tester
Insert paper for Smart 5 (60 pcs.)
CLP-Info
- H319: Causes serious eye irritation.
- H332: Harmful if inhaled.
- H412: Harmful to aquatic life with long lasting effects.
UniVer 3 Hardness Reagent Powder Pillows, pk/100