Filter products
Solutions for conductivity measurements
Conductivity Std. with TDS 100 µS/cm
Conductivity water (nominal 0 mS/cm), certified reference material, Test solution for measurement of electrolytic conductivity, traceable to PTB, Certipur®
CLP-Info
- H225: Highly flammable liquid and vapour.
- H314: Causes severe skin burns and eye damage.
- H332: Harmful if inhaled.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
Decalcifying solution (formic acid, alcoholic)
CLP-Info
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P233: Keep container tightly closed.
- P240: Ground and bond container and receiving equipment.
- P241: Use explosion-proof [electrical/ventilating/lighting/] equipment.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Electrolyte solution, nonaqueous, LiCl in ethanol (saturated)
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P332+P313: If skin irritation occurs: Get medical advice/attention.
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
Elektrolyte solution for hydrogen transfer test according to DIN EN 10209:2013-09
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P264: Wash skin thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P337+P313: If eye irritation persists: Get medical advice/attention.
- P390: Absorb spillage to prevent material damage.
EnviroMAT-Drinking Water Low
FILTER MEMBRANE INSET SET 2 PIECE
Conductivity standard solution, 1,412 µS/cm, KCl
MULTI-ELEMENT CALIBRATION STANDARD-2A
CLP-Info
- H228: Flammable solid.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P240: Ground and bond container and receiving equipment.
- P241: Use explosion-proof [electrical/ventilating/lighting/] equipment.
Palladium, 10% on activated carbon powder, eggshell, reduced
Permeate return line unheated, 2 m
POTASSIUM CHLORIDE SOLUTION SATURATED WITH SILVER CHLORIDE 3 MOL/L
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- H332: Harmful if inhaled.
- H373: May cause damage to organs through prolonged or repeated exposure .
- H412: Harmful to aquatic life with long lasting effects.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P340: Remove person to fresh air and keep comfortable for breathing.
Reagent set for analyser module Ammonium OA 110 or TresCon® A111 and TresCon® Uno TCU/A111, 120-day requirement: standards (5 mg/l, 50 mg/l)/reagents/cleaning agent. RSET/A111-2
CLP-Info
- H301: Toxic if swallowed.
- H312: Harmful in contact with skin.
- H373: May cause damage to organs through prolonged or repeated exposure .
- H410: Very toxic to aquatic life with long lasting effects.
- EUH032: Contact with acids liberates very toxic gas.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P273: Avoid release to the environment.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P312: Call a POISON CENTRE/doctor/ if you feel unwell.
Reagents Chloride (100 tests)
RL 230-2 PERMEAT RETURN LINE, HEATED, 230 VAC, 2M
ROTI®DipSlide PCA/TSA-Letheen, ready-to-use, sterile, for microbiology
Set of colored buffer solutions, pH 4.01, pH 7.00 and pH 10.01, 500 mL
CLP-Info
- H317: May cause an allergic skin reaction.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P272: Contaminated work clothing should not be allowed out of the workplace.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
- P342+P311: If experiencing respiratory symptoms: Call a POISON CENTER/doctor/
- P363: Wash contaminated clothing before reuse.
- P501: Dispose of contents/container to an approved waste disposal plant
StablCal® Formazin Turbidity Standards Stabilized formazin turbidity standard for use in turbidimeters.
W55 V2 Wiper Cleaning Kit for all TriOS Photometer sensors with a 10-meter permanently attached cable featuring a 4-pin M8 industrial circular connector Color: black
Wiper Blade Set for 1mm Track V2 included - Wiper shaft - 5 wiper blades for a 1mm track