Elma
Concentrate for ultrasonic baths elma lab clean A25
Product number:
6267522
Quantity per packaging unit:
1 Stück
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P102: Keep out of reach of children.
- P234: Keep only in original packaging.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P332+P313: If skin irritation occurs: Get medical advice/attention.
- P405: Store locked up.
Strongly alkaline, foam-inhibited cleaning concentrate for ultrasonic, immersion and splash cleaning of alkali-resistant parts and laboratory instruments, made of metal (including titanium), glass, ceramic and plastic. Removes biological contaminants, grease, oil, abrasives and polishing pastes, resinified and tarry residues, marker and label residues.
Not suitable for aluminium, magnesium, alloys of light metals and alkali-sensitive glass. Risk of tarnishing when used for nonferrous metals.
Not suitable for aluminium, magnesium, alloys of light metals and alkali-sensitive glass. Risk of tarnishing when used for nonferrous metals.
| Content: | 2.5 l |
|---|---|
| Feature: | Highly alkaline |
| Package size: | 1 Stück |
| Supply form: | Liquid concentrate |
| Type of packaging: | Canister |
| Packaging type: | - |
| Document | Download |
|---|---|
| Safety Data Sheet |
| UN Number: | 1814 | ADR Class: | 8 | Packaging group: | II |
|---|