Filter products
Reagents for photometry
Peroxodisulfate solution 6.5 g K2S2O8/l for determination of phenol index according to DIN 38409:1984, DEV H16
CLP-Info
- H412: Harmful to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P501: Dispose of contents/container to
Phenanthroline chloride solution 5 g/l for determination of iron according to DIN 38406 - 1:1983, DEV E1
CLP-Info
- H412: Harmful to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P501: Dispose of contents/container to
Phenanthroline solution for photometric determination of iron color reagent for METROHM
Phenol standard solution 1.00 g/l phenol for determination of phenol standard solution for METROHM
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to
Phenylene diammonium dichloride solution for determination of sulfide color reagent for METROHM
Phosphate standard solution C (PO4-P) = 250 mg/l standard solution for METROHM
Phosphate standard solution C (PO4-P) = 400 mg/l standard solution for METROHM
CLP-Info
- H302: Harmful if swallowed.
- H318: Causes serious eye damage.
- P270: Do not eat, drink or smoke when using this product.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P312: IF SWALLOWED: Call a POISON CENTRE/doctor/ if you feel unwell.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P330: Rinse mouth.
Potassium fluoride solution Potassium fluoride c(KF)=100 g/l Auxiliary solution for METROHM
CLP-Info
- H301+H311+H331: Toxic if swallowed, in contact with skin or if inhaled
- H318: Causes serious eye damage.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P405: Store locked up.
- P501: Dispose of contents/container to
Potassium fluoride solution approx. 6 mol/l for analysis auxiliary solution for METROHM
Potassium hexacyanoferrate(III) solution 80 g/l for determination of phenol index by destillation DIN 38409:1984, DEV H16-2 and H16-3
Potassium iodate standard solution 10.06 mg KIO3/l standard solution for METROHM
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P284: [In case of inadequate ventilation] wear respiratory protection.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P501: Dispose of contents/container to
Potassium peroxodisulfate solution 50 g/l sulphuric for determination of phosphate auxiliary solution for METROHM
Protein Digestibility Assay Kit
Pyrocatechol violet solution 0.5 g/l for photometric determination of aluminium according to DIN ISO 10566:1999, DEV E30
CLP-Info
- H412: Harmful to aquatic life with long lasting effects.
- P273: Avoid release to the environment.
- P501: Dispose of contents/container to
Reagent C 1 (modified) Phenanthroline chloride solution 4 g/l in water for determination of iron for Hach-Lange analyzers
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P332+P313: If skin irritation occurs: Get medical advice/attention.
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
Reagent green NaOH / dichloroisocyanurate for online TOC analysis in Metrohm analyzers
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P332+P313: If skin irritation occurs: Get medical advice/attention.
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
Reagent red 10% phophoric acid for online TOC analysis in Metrohm analyzers
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to
Reagent solution according to Tauber A for detection of ascorbic acid in flour
Reagent solution according to Tauber B for detection of ascorbic acid in flour
CLP-Info
- H272: May intensify fire; oxidiser.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P220: Keep away from clothing and other combustible materials.
- P284: [In case of inadequate ventilation] wear respiratory protection.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P501: Dispose of contents/container to
Reagent white 1 mol/l sodium persulfate for online TOC analysis in Metrohm analyzers