Filter products
Solvents
CLP-Info
- H225: Highly flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
- EUH066: Repeated exposure may cause skin dryness or cracking.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P243: Take action to prevent static discharges.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
Pentane, CHROMASOLV™, for HPLC, ≥99.0%
CLP-Info
- H225: Highly flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H361f: Suspected of damaging fertility.
- H373: May cause damage to organs through prolonged or repeated exposure .
- H411: Toxic to aquatic life with long lasting effects.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P240: Ground and bond container and receiving equipment.
- P273: Avoid release to the environment.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P314: Get medical advice/attention if you feel unwell.
- P403+P233: Store in a well-ventilated place. Keep container tightly closed.
PETROLEUM ETHER FOR DENATURATION
Purified Water (BP, Ph. Eur.) pure, pharma grade
CLP-Info
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P240: Ground and bond container and receiving equipment.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P403+P233: Store in a well-ventilated place. Keep container tightly closed.
TERT-BUTYL METHYL ETHER FOR ANALYSIS EMSURE® ACS
CLP-Info
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P233: Keep container tightly closed.
- P240: Ground and bond container and receiving equipment.
- P241: Use explosion-proof [electrical/ventilating/lighting/] equipment.
- P242: Use non-sparking tools.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
tert-Butyl methyl ether for gas chromatography ECD and FID SupraSolv®
CLP-Info
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P233: Keep container tightly closed.
- P240: Ground and bond container and receiving equipment.
- P241: Use explosion-proof [electrical/ventilating/lighting/] equipment.
- P242: Use non-sparking tools.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
TERT-BUTYL METHYL ETHER FOR LIQUID CHROMATOGRAPHY LICHROSOLV
CLP-Info
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- P243: Take action to prevent static discharges.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P308+P313: IF exposed or concerned: Get medical advice/attention.
tert-Butyl methyl ether, CHROMASOLV™, for HPLC, ≥99.8%
Test mixture for FAME columns Pack of 1 ml
Test mixture OPTIMA-Amine in ethanol, pack of 1 ml
CLP-Info
- H225: Highly flammable liquid and vapour.
- H302: Harmful if swallowed.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H351: Suspected of causing cancer .
- EUH019: May form explosive peroxides.
- P202: Do not handle until all safety precautions have been read and understood.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P312: IF SWALLOWED: Call a POISON CENTRE/doctor/ if you feel unwell.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
Tetrahydrofuran for analysis EMSURE® ACS,Reag. Ph Eur
CLP-Info
- H225: Highly flammable liquid and vapour.
- H302: Harmful if swallowed.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H351: Suspected of causing cancer .
- EUH019: May form explosive peroxides.
- P202: Do not handle until all safety precautions have been read and understood.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P312: IF SWALLOWED: Call a POISON CENTRE/doctor/ if you feel unwell.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
Tetrahydrofuran for liquid chromatography LiChrosolv®
CLP-Info
- H225: Highly flammable liquid and vapour.
- H302: Harmful if swallowed.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H351: Suspected of causing cancer .
- P201: Obtain special instructions before use.
- P202: Do not handle until all safety precautions have been read and understood.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P301+P312: IF SWALLOWED: Call a POISON CENTRE/doctor/ if you feel unwell.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
TETRAHYDROFURAN FOR SPECTROSCOPY UVASOL®
CLP-Info
- H225: Highly flammable liquid and vapour.
- H302: Harmful if swallowed.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H351: Suspected of causing cancer .
- EUH019: May form explosive peroxides.
- P201: Obtain special instructions before use.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P233: Keep container tightly closed.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
- P370+P378: In case of fire: Use to extinguish.
Tetrahydrofuran, CHROMASOLV™ Plus, for HPLC, inhibitor-free, ≥99.9%
CLP-Info
- H225: Highly flammable liquid and vapour.
- H302: Harmful if swallowed.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H351: Suspected of causing cancer .
- EUH019: May form explosive peroxides.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
Tetrahydrofuran, puriss. p.a., contains 250 ppm BHT as inhibitor, ACS Reagent, Reag. Ph. Eur., ≥99.9%
CLP-Info
- H225: Highly flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H361d: Suspected of damaging the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure .
- H412: Harmful to aquatic life with long lasting effects.
- P202: Do not handle until all safety precautions have been read and understood.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P273: Avoid release to the environment.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P331: Do NOT induce vomiting.
TOLUENE FOR ANALYSIS EMSURE™ ACS,ISO,Reag. Ph Eur
CLP-Info
- H225: Highly flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H361d: Suspected of damaging the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure .
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P284: [In case of inadequate ventilation] wear respiratory protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P308+P313: IF exposed or concerned: Get medical advice/attention.
Toluene, puriss. p.a., ACS Reagent, Reag. ISO, Reag. Ph. Eur., ≥99.7% (GC)
Water for analysis EMSURE®
Water for chromatography (LC-MS Grade) LiChrosolv®. CAS 7732-18-5, chemical formula H₂O.
Water for LC-MS, BAKER ANALYZED® LC-MS Reagent
Water Molecular biology grade