Filter products
Ion chromatography standards
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard manganese 1.000 g Mn/l Mn(NO3)2 * n H2O in nitric acid 0.5 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- H302+H312+H332: Harmful if swallowed, in contact with skin or if inhaled
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H373: May cause damage to organs through prolonged or repeated exposure .
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P501: Dispose of contents/container to
ICP standard mercury 1.000 g Hg/l Hg in nitric acid 0.5 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to
ICP standard molybdenum 1.000 g Mo/l Mo in nitric acid 1 mol/l with traces of hydrofluoric acid traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard neodymium 1.000 g Nd/l Nd2O3 in nitric acid 0.5 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- P234: Keep only in original packaging.
- P390: Absorb spillage to prevent material damage.
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard neodymium 1.000 g Nd/l Nd2O3 in hydrochloric acid approx. 0.5 mol/l
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H350i: May cause cancer by inhalation.
- H360D: May damage the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure .
- H412: Harmful to aquatic life with long lasting effects.
- P201: Obtain special instructions before use.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P273: Avoid release to the environment.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P405: Store locked up.
- P501: Dispose of contents/container to
ICP standard nickel 1.000 g Ni/l NiO in nitric acid 0.5 mol/l traceable to NIST
CLP-Info
- H301+H311: Toxic if swallowed or in contact with skin
- H314: Causes severe skin burns and eye damage.
- H330: Fatal if inhaled.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor/
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P405: Store locked up.
- P501: Dispose of contents/container to
ICP standard niobium 1.000 g Nb/l NbCl5 in hydrofluoric acid 1 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- P234: Keep only in original packaging.
- P390: Absorb spillage to prevent material damage.
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard osmium 1.000 g Os/l (NH4)2OsCl6 in hydrochloric acid 1 mol/l
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to
ICP standard palladium 1.000 g Pd/l Pd(NO3)2 in nitric acid 1 mol/l traceable to NIST
ICP standard phosphorus 1.000 g P/l KH2PO4 in water traceable to NIST
ICP standard phosphorus 1.000 g P/l H3PO4 in water traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- P234: Keep only in original packaging.
- P390: Absorb spillage to prevent material damage.
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard platinum 1.000 g Pt/l H2[PtCl6] in hydrochloric acid 2 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
ICP standard potassium 1.000 g K/l KNO3 in nitric acid 0.5 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard praseodymium 1.000 g Pr/l Pr6O11 in nitric acid 0.5 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to
ICP standard rhenium 1.000 g Re/l Re in nitric acid 1 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- P234: Keep only in original packaging.
- P390: Absorb spillage to prevent material damage.
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard rhodium 1.000 g Rh/l RhCl3 in hydrochloric acid 1 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to
ICP standard rubidium 1.000 g Rb/l Rb2CO3 in nitric acid 5 % traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- P234: Keep only in original packaging.
- P390: Absorb spillage to prevent material damage.
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard ruthenium 1.000 g Ru/l RuCl3 in hydrochloric acid 1 mol/l
CLP-Info
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P406: Store in a corrosion-resistant/ container with a resistant inner liner.
ICP standard samarium 1.000 g Sm/l Sm2O3 in nitric acid 0.5 mol/l traceable to NIST
CLP-Info
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
- P260: Do not breathe dust/fume/gas/mist/vapours/spray.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER/doctor/
- P405: Store locked up.
- P501: Dispose of contents/container to
ICP standard scandium 1.000 g Sc/l Sc2O3 in nitric acid 2 mol/l traceable to NIST