Filter products
Search results
Divided inner door with cell therapy compartmentalisation. This option is equipped with additional partition walls for spatial incubation subdivision to prevent mixing up of sample vessels.
Environmental chambers are ideal for material testing under dynamic conditions. The standard rapid alternation speeds of approx. 5 K/min enable standard-compliant testing.Homogeneous climate conditions thanks to APT.line™ preheating chamber technologyTouchscreen controller with time-segment and real-time programmingInternal data logger, measured values can be read out via USBProgrammable condensation protectionTroubleshooting system with visual and acoustic alarmsHeated viewing window with LED interior lightingBINDER Multi Management Software APT-COM™ Basic EditionClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmEthernet interfaceAdjustable ramp functionIntegrated chart recorderDoor heatingInner chamber made of stainless steel1 stainless steel rackCFC-free refrigerant R-452AModels with 480 V nominal voltage are equipped with a voltage and frequency converter.
Environmental chambers are ideal for material testing under dynamic conditions. The standard rapid alternation speeds of approx. 5 K/min enable standard-compliant testing.Homogeneous climate conditions thanks to APT.line™ preheating chamber technologyTouchscreen controller with time-segment and real-time programmingInternal data logger, measured values can be read out via USBProgrammable condensation protectionTroubleshooting system with visual and acoustic alarmsHeated viewing window with LED interior lightingBINDER Multi Management Software APT-COM™ Basic EditionClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmEthernet interfaceAdjustable ramp functionIntegrated chart recorderDoor heatingInner chamber made of stainless steel1 stainless steel rackHumidity regulation with capacitive humidity sensor and responsive steam humidificationAutomatic water and wastewater managementIntegrated 20 l water storage tank4 zero-voltage relay contactsCFC-free refrigerant R-452AModels with 480 V nominal voltage are equipped with a voltage and frequency converter.
Feedthrogh with silicone plug - 30 mm, left
Drying and heating chambers are suitable for routine drying and sterilisation tasks with homogeneous temperature distribution.Uniform drying conditions thanks to APT.line™ preheating chamber technologyIdentical test conditions throughout the chamber interior independent of sample size and quantityAdjustable exhaust air flapClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmWith natural convectionController with timer functions
Drying and heating chambers are suitable for routine drying and sterilisation tasks with homogeneous temperature distribution.Uniform drying conditions thanks to APT.line™ preheating chamber technologyIdentical test conditions throughout the chamber interior independent of sample size and quantityAdjustable exhaust air flapClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmWith forced convectionController with timer functions
Drying and heating chambers are suitable for routine drying and sterilisation tasks with homogeneous temperature distribution.High temperature accuracy thanks to APT.line™ technologyElectromechanical control of the exhaust air flapChambers up to 115 l are stackableErgonomic handle designUSB connection for data recordingClass 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarmWith natural convectionController with LCD display
Drying ovens Model FD 115 up to +300°C, cap.116 ltrs 230 V 1~ 50/60 Hz
Max. load per rack 70 kg.
Grid shelf incl. shelf support.
Incubators with homogeneous temperature distribution ensure the best results for a wide range of incubation tasks.High temperature accuracy thanks to APT.line™ technology100 °C disinfection routineHigh process reliabilityController with LCD displayElectromechanical control of the exhaust air flapInner door made of tempered safety glass2 chrome-plated racksChambers up to 115 l are stackableClass 3.1 integrated independent temperature safety device (DIN 12880) with visual alarmErgonomic handle designUSB connection for data recordingIncubators with forced convectionAdjustable fan speedTemperature stability ±0.1 K (at 37 °C)
The ultra-low temperature freezers are suitable for stable long-term storage of sensitive samples at -90 °C and are characterised by low energy consumption, convenient operation, and individual safety concept.Powerful cascade compression cooling unitEnvironmentally friendly refrigerants R-290 and R-170Thermal insulation with unique long-life VIPs (vacuum insulation panels)Innovative door sealing concept reduces ice formationErgonomic door handleInterior completely made of stainless steelRemovable inner doors made of stainless steel3 flexibly positionable shelves made of stainless steelPotential-free alarm contact for in-house alarm systemInternal data logger, measured values can be read out in open format via USBEthernet interface2 access ports Ø 28 mm, rearUltra-low temperature freezer with water cooling
CO2 emergency cooling
Suitable for routine cell cultivation applications and incubation tasks, also for complex approaches under hypoxic conditions. Models with additional O2 control are available.Anti-contamination concept with 180 °C hot air sterilizationCO2 sensor with single-beam infrared technologySeamless inner chamber made of stainless steelFanless interior with Venturi CO2 gas mixing nozzleInternal data logger, measured values can be read out via USBTroubleshooting system with visual and acoustic alarmsInterfaces: Ethernet, USB, zero-voltage alarm contactHumidification system with condensation protectionTouchscreen controllerFail-safe CO2 system for protecting the pH of cell cultures
Suitable for routine cell cultivation applications and incubation tasks, also for complex approaches under hypoxic conditions. Models with additional O2 control are available.Anti-contamination concept with 180 °C hot air sterilizationCO2 sensor with single-beam infrared technologySeamless inner chamber made of stainless steelFanless interior with Venturi CO2 gas mixing nozzleInternal data logger, measured values can be read out via USBTroubleshooting system with visual and acoustic alarmsInterfaces: Ethernet, USB, zero-voltage alarm contactContamination-safe humidification system without water panTouchscreen controllerFail-safe CO2 system for protecting the pH of cell culturesInner door divided into 8 parts with cell therapy compartmentalizationStainless steel inner door with 8 separate glass doors4 shelf levels with 8 insertsIndividual inserts can be pulled out completelyEach level is physically separated by an additional partition wall
Set of 3 chamber racks. For safe storage of sensitive samples in standard cryoboxes.
Set of 4 chamber racks with drawers. For safe storage of sensitive samples in standard cryoboxes.
For gentle, fast drying without residues, incrustations or oxidation.Direct heat transfer through large thermal conducting platesProgram-controlled drying monitoring with automatic ventilation at end of processInternal data logger, measured values can be read out in open format via USBInert gas connectionShatterproof, spring-mounted safety glass panelLarge viewing windowAluminum expansion racks, can be custom-positionedEthernet interfaceFor non-flammable solventsController with digital display of pressure and temperatureAccess port DN 16
For safe storage of sensitive samples in standard cryoboxes.
For safe storage of sensitive samples in standard cryoboxes.