The portable hand-held measuring instrument SD 315 Oxi meets the daily requirements for a robust and reliable instrument for the determination of dissolved oxygen in aqueous media. The Clark oxygen sensor with integrated temperature probe enables immediate measurements without time-consuming run-in time (polarisation time).

  • Simple calibration against air or according to DIN EN ISO 5814
  • Alarm function with adjustable limits
  • Automatic pressure and temperature compensation
  • Auto Hold Function
  • Automatic switch-off individually selectable from 1 to 120 min
  • Backlit LCD display
  • Sensor status display in % after each calibration
  • Salinity correction
  • Parameter: dissolved oxygen (O2), O2 concentration in mg/l, O2 saturation in %, temperature in °C/°F
  • Battery status indicator
  • Flexible stand at the rear allows the unit to be set up or fastened to a belt
  • Data transfer and evaluation via software possible

Scope of supply: Instrument, protective covering, electrode holder, carrying case, galvanic oxygen sensor with 2 m cable, KOH refill electrolyte, spare membrane, calibration bottle with sponge, batteries, manual
Battery/ rechargeable battery: 2 x AAA
Concentration: 0 ... 70 mg/l
Depth: 100 mm
Dimensions (WxDxH): 164 x 100 x 37 mm
Height: 37 mm
IP code: IP 67
Max. temperature: 50 °C
Min. temperature: 0 °C
Package size: 1 Stück
Saturation: 0 ... 600 %
Temperature: 0 ... 50 °C
Type: SD 315 Oxi Set 1
Type of auxiliary energy: Battery
Weight: 302 g
Width: 164 mm
Packaging type: -
Document Download
Safety Data Sheet
Accessories
[LLG] Accessories for oxygen meter SD 315 Oxi
AQUALYTIC
Accessories for oxygen meter SD 315 Oxi

Service kit for oxygen sensor SD310 OXI incl.3 spare part membranes, 100ml bottle

Product number: 6272367
Quantity per PU: 1 Stück
Electrode, 1,5m cable for SD310
AQUALYTIC
Spare electrode for oxygen meter SD 315 Oxi

Platinum cathode/lead anode.

Product number: 6272364
Quantity per PU: 1 Stück
Cable length
[LLG] Refill electrolyte (KOH)
AQUALYTIC
Refill electrolyte (KOH)
ghs05 Danger
  • H290: May be corrosive to metals.
  • H314: Causes severe skin burns and eye damage.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
  • P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310: Immediately call a POISON CENTER/doctor/

Spare electrolyte KOH 100, 100ml for SensoDirect Oxi UN 1814, 8, II, (E)

Product number: 6270797
Quantity per PU: 1 Stück