WTW
Oxygen meter inoLab® Oxi 7310 Set 1
Product number:
9920109
Quantity per packaging unit:
1 Stück
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P302+P352: IF ON SKIN: Wash with plenty of water/
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Reliable Documentation for dissolved oxygen measurement: This is the inoLab® Oxi 7310 or inoLab® Oxi 7310P. A modern backlit graphic display with menu controlled user interface allows easy and intuitive operation. The mini USB-B interface provides fast data transfer to a PC. The internal memory can record up to 5000 GLP complying data including ID, date and time. The housing and the keypad are easy-to-clean. The inoLab® Oxi 7310 supports the long proven WTW galvanic sensors, CellOx® 325 and StirrOx® G. A calibration history of the 10 last calibrations allows conclusions on the state of the sensor. Calibrations versus external standards e.g. Winkler titration, are possible, too. The meter includes automatic barometric pressure and temperature compensation.
Scope of supply: Device, oxygen sensor CellOx® 325, electrolyte, abrasive foil, replacement membrane caps, universal power supply, stand, operating instructions, CD-ROM with software, USB cable
Scope of supply: Device, oxygen sensor CellOx® 325, electrolyte, abrasive foil, replacement membrane caps, universal power supply, stand, operating instructions, CD-ROM with software, USB cable
| Accuracy temperature: | ±0.1 °C |
|---|---|
| Battery/ rechargeable battery: | 4 x 1.5 V, AA |
| Concentration: | 0 ... 90 mg/l |
| Concentration accuracy: | ±0.5 % of measured value |
| Concentration resolution: | 0.01/0.1 |
| Depth: | 230 mm |
| Dimensions (WxDxH): | 190 x 230 x 80 mm |
| Height: | 80 mm |
| IP code: | IP 43 |
| Max. temperature: | 105 °C |
| Min. temperature: | -5 °C |
| Package size: | 1 Stück |
| Partial pressure: | 0 ... 1250 hPa |
| Partial pressure accuracy: | ±0.5 % of measured value |
| Partial pressure resolution: | 0.1/1 |
| Power supply: | 100 ... 240 V, 50/60 Hz |
| Saturation: | 0 ... 600 % |
| Saturation accuracy: | ±0.5 % of measured value |
| Saturation resolution: | 0.1/1 |
| Temperature: | -5 ... 105 °C |
| Type: | inoLab® Oxi 7310 Set 1 |
| Type of auxiliary energy: | Battery/mains connection |
| Width: | 190 mm |
| Packaging type: | - |
| Document | Download |
|---|---|
| Safety Data Sheet |
Alternative products
Accessories