Extraction

Filter

 LLG-Extraction thimbles, cellulose

LLG

Neutral and fat free. With excellent retention capacity. Ash content <0.1 %....

LLG-Extraction thimbles 37x130mm cellulose, pack of 25

LLG

PO number Package size Price per package    

1

6256301

This product of our assortment corresponds with your search.

25 piece Login / Register here
shopping_cart

LLG-Extraction thimbles 58x170mm cellulose, pack of 25

LLG

PO number Package size Price per package    

1

6263174

This product of our assortment corresponds with your search.

Minimum order quantity 5 packs or a multiple!
25 piece Login / Register here
shopping_cart

 Extraction thimbles MN 645, pure cellulose

MACHEREY-NAGEL

  • Fat determination in food and feed
  • Determination of binder content in asphalt
  • Analysis of soil contaminants
  • Determination of additives in rubber and elastomers
...

 Cellulose-Extraction thimbles Grade 603

Cytiva

Manufactured in pure cellulose according to DIN 12449....

 Extraction apparatuses acc. to Soxhlet, with Dimroth condenser, DURAN® tubing

Lenz

Extraction apparatus, Soxhlet-pattern. With Dimroth condenser and round-bottom flask.
Made of Duran ® tubing....

 Extraction Thimbles, cellulose

Hahnemühle

For reliable and fast analysis in the areas of food control and environmental monitoring. Suitable for Soxhlet-type, Tecator-type or similar devices, to extract certain components out of solid material with an appropriate solvent.

  • Made of pure cellulose that is totally free from binding elements
  • High purity of selected cellulose guarantees reliable and replicable results
  • The consistent high porosity ensures fast flow through
  • High fitting accuracy for all available extraction systems
  • Wall thickness 1.3 mm at thimbles with ≤35 mm inner diameter, 1.7 mm at thimbles with >35 mm inner diameter
  • For two systems
  • Grade 900: Soxhlet Extraction, Grade 901: Tecator Extraction
...

 Accessories for Extraction tubes Mojonnier

Gerber

...

 Accessories for Kjeldahl rapid sample digestors

Behr

behrotest ® standard digestion vessels have standard dimensions. That means they fit into digestion and distillation units of most brands. Of course, it also means that standard digestion vessels of most brands can be used with behr distillation units....

 behrotest® CF 2+2 and CF 6, Semi-automatic Crude Fibre Extraction

Behr

They are ideally suited for:

  • total crude fibre determination (part of the Weender animal feed analysis as performed in Europe)
  • neutral detergent fibre and acid detergent fibre determination (NDF and ADF according to Van Soest)
  • acid detergent lignin determination (ADL according to Van Soest)
  • different fractions of fibre (cellulose, hemicellulose and pectin) behrotest® semi-automatic crude fibre extraction units simplify everday life in the lab:
  • Easy operation
  • The analyst is guided through the procedure by messages on the display.
...

 Workstations for SMA ARB

Behr

Workstation model SMA-ARB

The behrotest ® workstation model SMA-ARB is a basic system for simultaneous aqua regia digestion of either 6 or 12 samples for heavy metals analysis.

System components:

  • Precision 6 or 12 sample SMA heating block for round-bottom sample vessels of Ø 41.8 mm, temperature range 20 to 300 °C.
  • External ET 2 controller, operating range 20 to 399°C. Time settings from 10 to 120 min. and continuous operation.
  • 6 or 12 SR 2 250 ml round-bottom sample vessels with standard taper mouth and PVDF collar.
  • 6 or 12 RFK 1 Allihn reflux condensers.
  • 6 or 12 AS 1 absorption vessels.
  • SG/B stainless steel vessel holding frame for 6 or 12 sample vessels.
  • Support scaffold with cooling water distributor and storage holder for 6 or 12 condensers.
...

 behrotest® Multi-sample Extractors for Twisselmann Extraction

Behr

Economical and user-friendly units for extraction in accordance with Twisselmann:

  • each sample position is individually adjustable
  • cooling water distributor ensures an even cooling at all sample positions
  • practical stand for holding the condensers securely between the extractions
  • mounts for holding the spacers after the removal of the sample containers
...

 Extraction kits Copure® QuEChERS

Th. Geyer

Extraction and clean-up mixtures for sample preparation in the pesticide analysis of vegetable foodstuffs according to EN 15662 using GC/MS or LC/MS after acetonitrile extraction and purification using the dispersive SPE-QuEChERS method.

The samples are first extracted with Mix A. Purification is done with one of the following mixtures:...

 Complete Compact Extraction System

Behr

Compact Extraction System in accordance with Twisselmann
Complete compact extraction system with stand, heating module, mount, hoses and glassware (round-bottom reaction flask, extractor, Dimroth condenser for extraction)....

 Complete compact extraction systems, with heating

Behr

Complete compact extraction systems with stand, heating module, mount, hoses and glassware (round-bottom reaction flask, extractor, Dimroth condenser for extraction). Infinitely variable heating regulation.

  • practical stand for holding the condensers securely between extractions
  • extractor sizes from 30 ml to 5000 ml
  • the use of extractors with a stopcock eliminates the need for any additional distillation after extraction
  • Condensers with screwed-on tubing nipples
...

 Exhaust Device, borosilicate

Behr

  • Filter mountings, 400 ml, with thread
  • PP funnels with thread
  • Slotted sieve plate with 2 gaskets
  • Stainless steel rack
  • Water jet pump
...

 Extraction Thimbles MN 649, glass micro fibers

MACHEREY-NAGEL

  • Pollution monitoring, air sampling
  • High temperature filtration (up to +500 °C)
  • For solvents incompatible with cellulose thimbles (for example strong acids or bases)
...

 Extraction thimbles, Borosilicate glass

Hahnemühle

Recommended for Soxhlet extraction with solvents, which are incompatible with cellulose fibres and for filtration of air and gas streams.

  • Made of 100 % pure borosilicate fibres, without binding elements
  • High loading capacity and highly permeable to air
  • Thickness is 1.5 mm (diameter < 33 mm)
  • High retention of small particles, > 99 % according to BS 4400
  • Good stability at high temperatures up to 500 °C
  • Recommended for hot, moist, and acidic gases
  • Gravimetric determination of particles in hot gases
...

 Extraction thimbles, Cellulose

Cytiva

Supplied in packs of 25. Dimensions given are nominal internal diameter x external length in mm....

 Extraction tubes Mojonnier, Borosilicate glass 3.3

Gerber

...

 Extraction Unit for the Randall Method

Behr

Manual apparatus for hot extraction according to Randall. Several times faster than a customary Soxhlet extraction. Incl. 1 set of extraction thimbles, 100 ml.

  • Optimal safety thanks to screw-fastened extraction units
Multiple position extraction units:
  • Every extraction thimble with sample can be independently adjusted
  • The user can lower and raise all the extraction units into/out of the heating chamber with a single lever
  • Every heating position has a separate temperature control
...

 Hydrolysis/crude fibre separation set , behrotest

Behr

behrotest ® Hydrolysis apparatus, complete with:

  • Serial heating unit with individually adjustable heating places
  • Cooling water distribution with condenser rack and hoses
  • Beakers (600ml), cold fingers
...

 Accessories for Sample Concentrators SBHCONC / 1

Bibby

...

 Serial Extraction Apparatus behrotest® for Soxhlet-/Fat-Extraction

Behr

behrotest ® serial heaters are the economical and user-friendly solution for the classic Soxhlet or fat extraction:

  • complete with reaction vessels, extraction spacers and coolers
  • energy for each sample position is individually adjustable
  • cooling water distributor ensures even cooling at all sample positions
  • practical stand for holding the condensers securely between extractions
  • mounts for holding the extraction spacers after removing the sample vessels
  • S models: The extractors with stopcock do away with the need for any additional distillation after extraction
...

 Serial heating unit for reflow distillation

Behr

Complete equipment for reflux distillation, consisting of

  • Hot bench, 4 or 6 heating positions
  • Standing basin
  • Stand rods
  • Cooling water distribution with condenser rack and cooler stand
  • Reaction flask
  • Behr high performance glass coolers
...

Add to shopping cart